bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.04.14.488129

Digital data repository and automatic analysis framework for FDOPA PET neuroimaging

Abstract

IntroductionFDOPA PET has been used extensively to image the human brain in many clinical disorders and has the potential to be used for patient stratification and individualized treatment. However, to reach its full and effective clinical translation, FDOPA PET requires both a robust data infrastructure and analytical protocol that are capable of ensuring high quality data and metadata, accurate biological quantification, and replicable results. In this study we evaluate a digital data repository and automated analytical framework for FDOPA PET neuroimaging that can produce an individualised quantification of dopamine synthesis capacity in the living human brain. MethodsThe imaging platform XNAT was used to store the Kings College London institutional brain FDOPA PET imaging archive, alongside individual demographics and clinical information. A fully automated analysis pipeline for imaging processing and data quantification was developed in Python and integrated in XNAT using the Docker technology. Reproducibility was assessed in test-retest datasets both in controls and patients with psychosis. The agreement between the automated analysis estimates and the results derived by the manual analysis were compared. Finally, using a sample of healthy controls (N=115), a sensitivity analysis was performed to explore the impact of experimental and demographic variables on the FDOPA PET measures. ResultsThe final data repository includes 892 FDOPA PET scans organized from 23 different studies, collected at five different imaging sites. After removing commercials studies, the infrastructure consisted of 792 FDOPA PET scans from 666 individuals (female 33.9%, healthy controls 29.1%) collected from four different imaging sites between 2004-2021. The automated analysis pipeline provided results that were in agreement with the results from the manual analysis, with a Pearsons correlation that ranged from 0.64 to 0.99 for Kicer, and from 0.79 to 1.00 for SUVR. The mean absolute difference between the two pipelines ranges from 3.4% to 9.4% for Kicer, and from 2.5% to 12.4% for SUVR. Moreover, we found good reproducibility of the data analysis by the automated pipeline (in the whole striatum for the Kicer: ICC for the controls = 0.71, ICC for the psychotic patients = 0.88). From the demographic and experimental variables assessed, gender was found to most influence striatal dopamine synthesis capacity (F = 10.7, p <0.001), with women showing greater dopamine synthesis capacity than men, while the effects of weight, age, injected radioactivity, and scanner, varied by brain region and parameter of interest. ConclusionsCombining information from different neuroimaging studies has allowed us to test comprehensively the automated pipeline for quantification of dopamine synthesis capacity using FDOPA PET data and to validate its replicability and reproducibility performances on a large sample size. This validation process is a necessary methodological step for the development of the clinical application of FDOPA PET as precision medicine biomarker. The proposed infrastructure is generalisable behind the FDOPA radiotracer.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nordio, G., Easmin, R., Giacomel, A., Dipasquale, O., Martins, D., Williams, S., Turkheimer, F. E., Howes, O., Jauhar, S., Rogdaki, M., McCutcheon, R., Kaar, S., Vano, L., Rutigliano, G., Angelescu, I., Borgan, F., D'Ambrosio, E., Dahoun, T., Kim, E., Kim, S., Bloomfield, M., Egerton, A., Demjaha, A., Bonoldi, I., Nosarti, C., MacCabe, J. H., McGuire, P., Matthews, J., Talbot, P., Veronese, M.. 2022-04-15. Digital data repository and automatic analysis framework for FDOPA PET neuroimaging. https://doi.org/10.1101/2022.04.14.488129

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗