bioRxiv Science⌕ Search

bioRxiv · 10.1101/2021.11.12.468264

A new approach to the determination of tubular membrane capacitance: passive membrane electrical properties under reduced electrical conductivity of the extracellular solution

Abstract

The tubular system of cardiomyocytes plays a key role in excitation-contraction coupling. To determine the area of the tubular membrane in relation to the area of the surface membrane, indirect measurements through the determination of membrane capacitances by electrophysiological measurements are currently used in addition to microscopic methods. Unlike existing electrophysiological methods based on an irreversible procedure (osmotic shock), the proposed approach uses a reversible short-term intermittent increase in the electrical resistance of the extracellular medium. The resulting increase in the lumen resistance of the tubular system makes it possible to determine separately capacitances of the tubular and surface membranes from altered capacitive current responses to subthreshold voltage-clamped rectangular pulses. Based on the analysis of the time course of capacitive current, computational relations were derived which allow to quantify elements of the electrical equivalent circuit of the measured cardiomyocyte including both capacitances. The exposition to isotonic low-conductivity sucrose solution is reversible which is the main advantage of the proposed approach allowing repetitive measurements on the same cell under control and sucrose solutions. In addition, it might be possible to identify changes in both surface and tubular membrane capacitances caused by various interventions. Preliminary experiments in rat ventricular cardiomyocytes (n = 10) resulted in values of the surface and tubular capacitances 72.3 {+/-} 16.4 and 42.1 {+/-} 14.7 pF, respectively, implying the fraction of tubular capacitance/area of 0.36 {+/-} 0.08. We conclude that the newly proposed method provides results comparable to those reported in literature and, in contrast to the currently used methods, enables repetitive evaluation of parameters describing the surface and tubular membranes. It may be used to study alterations of the tubular system resulting from various interventions including associated cardiac pathologies. Author summaryThe cell membrane of cardiomyocytes is invaginated forming a net of tubules through the whole cell (the tubular system). These invaginations are essential for the coordinated contraction of cardiomyocytes. Various cardiac diseases may lead to an alteration of the tubular system and vice versa alteration of the tubular system may result in cardiac dysfunction. Therefore, it is desirable to investigate the tubular membrane separately. Unfortunately, it is not easy and methods currently used for this purpose provide diverse results. The widely used detubulation methods (separating the tubular and surface membrane by an osmotic shock) are irreversible. It makes impossible repeated measurements on the same cell, thus, disabling evaluation of parameters describing the surface and tubular membranes and particularly testing changes in the tubular system. We developed an alternative approach based on the electrical separation of the tubular and surface membranes induced by exposition of the cardiomyocyte to an isotonic sucrose solution with low electrical conductivity. It allows to quantify the approximate area of the surface and tubular membrane using evaluation of electrical capacitance of both membrane areas. Measurements can be repeated several times on the same cell.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Simurda, J., Simurdova, M., Svecova, O., Bebarova, M.. 2021-11-13. A new approach to the determination of tubular membrane capacitance: passive membrane electrical properties under reduced electrical conductivity of the extracellular solution. https://doi.org/10.1101/2021.11.12.468264

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Autonomous Homeostatic Synthetic Cells via Self-Gating DNA Nanopores

Homeostasis is a fundamental hallmark of living organisms, arising from the complex interplay between biochemical reactions and regulatory feedback systems. Reconstituting such self-regulating behaviour in minimal synthetic cells enables continuous, persistent operation of biochemical reactions for extended amount of time. In this work, we demonstrate a minimal homeostatic synthetic cell capable of autonomous flux regulation using DNA nanotechnology and bottom-up synthetic biology. Our homeostatic architecture consists of Giant Unilamellar Vesicles (GUVs) equipped with gated DNA nanopores, encapsulated in vitro transcription (IVT) machinery, and an RNA degradation system. We achieve homeostasis under varying external chemical stimuli specifically varying concentrations of rNTPs by implementing a negative feedback loop between rNTP influx and RNA production. In our system, DNA nanopores facilitate the influx of rNTPs from the external environment, driving internal transcription. Crucially, the transcription process generates RNA "blockers" designed to bind and gate the DNA nanopores, thereby attenuating further rNTP influx. Our system is dynamic as encapsulated RNases slowly degrade the RNA blockers, allowing the pores to reopen as blocker concentration goes down. We first characterise the functionality and gating efficiency of the DNA nanopores using both pre-synthesised and in situ produced DNA and RNA blockers. We then demonstrate that rNTP flux through these pores is sufficient to drive IVT within the GUVs. Finally, by integrating these modules, we demonstrate robust homeostasis: the system maintains a steady-state level of RNA production for up to 16 hours. By harnessing the controllability of negative feedback loop, we demonstrate thresholding of the homeostasis level using single-stranded regulator DNA. This work establishes a versatile framework for engineering adaptive and self-sustaining responsive nanomaterials and synthetic cell chassis.

biophysics↗

A Generic Numbering Scheme for TMEM16 Scramblases

The TMEM16 family of calcium-activated phospholipid scramblases (CaPLSs) and chloride channels (CaCCs) performs diverse physiological functions that include regulation of blood coagulation and apoptotic signaling, through a shared ten-transmembrane-helix (TM) architecture organized around a hydrophilic lipid-translocating groove. Mechanistic studies of TMEM16 family members have been hampered by the absence of a unified positional reference framework that would permit direct comparison of structurally equivalent residues across paralogs with different sequence numbering systems. Here we introduce a generic numbering scheme for TMEM16 scramblases (GNS-TMEM16), modeled on the Ballesteros & Weinstein system established for class A G protein-coupled receptors. A reference alignment (TMEM16-RA) was constructed from twelve human and mouse TMEM16 scramblases (TMEM16C/D/E/F/G/J) using structure-based ClustalW alignment of the ten TM helices. From this alignment, a TM-specific reference residue (TsRR) was identified for each helix by hierarchical application of three criteria: (1) 100% conservation in the core TMEM16-RA; (2) conservation in an augmented reference alignment (TMEM16-ARA) incorporating a group of phylogenetically more distant homologs composed of nhTMEM16, afTMEM16, TMEM16K, TMEM16A, and TMEM16B; and (3) structural and functional considerations, including helix-perturbing character, groove localization, conserved motif membership, and central TM position. The resulting ten TsRRs are Y1.50, W2.50, R3.50, E4.50, F5.50, P6.50, E7.50, D8.50, W9.50, and E10.50, and are illustrated in mTMEM16F. Each residue is assigned the identifier N.m(k), where N is the TM number, m is the position relative to the TsRR (for which m = 50), and k is the absolute sequence number. Loop residues receive dual identifiers referenced to the TsRRs of both flanking helices. Application of the GNS-TMEM16 is illustrated with the comparisons of the groove-opening measurements using pairwise distances between residues identified by their N.m indices to be corresponding across mTMEM16F, afTMEM16, and nhTMEM16. The results bring to light the advantages of corresponding residues identification in different TMEM16 proteins and show that the mammalian scramblase undergoes substantially larger separation at the extracellular groove entrance than either fungal homolog. Comparison of mutagenesis data guided by N.m correspondence shows at the conserved (E3.55,R6.26) salt-bridge locus, Ala substitution reduces activity more than 100-fold in nhTMEM16 but less than 2-fold in afTMEM16, illustrating that the GNS identifies structural equivalence of position without implying functional equivalence of the residue, which is a distinct advantage of GNS in providing mechanistic interpretation across paralogs. Also described is a protocol for extending the GNS-TMEM16 to uncharacterized protein sequences, including AlphaFold-predicted models, using structural superposition to mTMEM16F. Thus, the presented GNS-TMEM16 provides a stable positional reference for the integration and comparative analysis of structural, computational, and functional data across the TMEM16 family, utilizing a construction strategy applicable to yet other polytopic membrane protein families sharing a common transmembrane fold.

biophysics↗

An agent-based 3D model of non-genetic adaptation in cancer tissues under electrical, mechanical, and hypoxic stress

Non-genetic adaptation enables cancer cells to alter their phenotype under stress without requiring new mutations. However, the mechanisms by which electrical, mechanical, and hypoxic cues combine to shape this process in 3D tissues remain poorly understood. This work presents an agent-based tumor model that integrates vascular oxygen supply, a globally imposed electric field, mechanically mediated crowding and compression cues, phenotype transitions, cell growth, mitosis, death, and inheritance of adaptive memory across division. The simulated tumors exhibit a three-stage trajectory consisting of necrosis onset, transient collapse of live mass, and partial regrowth accompanied by progressive accumulation of adapted cells. Continuous electrical stimulation produces a dose-dependent reduction in live mass while markedly increasing the adapted fraction, with comparatively limited changes in final necrotic burden. This response is strongly conditioned by mechanics and reshapes (and is reshaped by) adaptive capacity. Pulsed stimulation further shows that, in the model, electric field amplitude and temporal schedule jointly determine memory phenomena, phenotypic diversification, and growth recovery. These results show that coupling local oxygen availability, mechanical constraints, electrical forcing, and history-dependent phenotype transitions can generate distinct tissue-level patterns of phenotypic heterogeneity. Both stimulus magnitude and temporal protocol influenced the resulting population structure, suggesting that the history of physical stress may be an important determinant of adaptive dynamics in spatially organized tumor models.

biophysics↗