bioRxiv Science⌕ Search

bioRxiv · 10.1101/2021.08.03.454878

Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy

Abstract

The single-photon timing and sensitivity performance and the imaging ability of asynchronous-readout single-photon avalanche diode (SPAD) array detectors have opened up enormous perspectives in fluorescence (lifetime) laser scanning microscopy (FLSM), such as super-resolution image scanning microscopy and high-information content fluorescence fluctuation spectroscopy (FFS). However, the strengths of these FLSM techniques depend on the many different characteristics of the detector, such as dark-noise, photon-detection efficiency, after-pulsing probability, and optical-cross talk, whose overall optimization is typically a trade-off between these characteristics. To mitigate this trade-off, we present a novel SPAD array detector with an active cooling system, which substantially reduces the dark-noise without significantly deteriorating any other detector characteristics. In particular, we show that lowering the temperature of the sensor to -15{degrees}C significantly improves the signal-to-noise ratio due to a 10-fold decrease in the dark-count rate compared to room temperature. As a result, for imaging, the laser power can be decreased by more than a factor of three, which is particularly beneficial for live-cell super-resolution imaging, as demonstrated in fixed and living cells expressing GFP-tagged proteins. For FFS, together with the benefit of the reduced laser power, we show that cooling the detector is necessary to remove artifacts in the correlation function, such as spurious negative correlations observed in the hot elements of the detector, i.e., elements whose dark-noise is substantially higher than the median value. Overall, this detector represents a further step towards the integration of SPAD array detectors in any FLSM system. SIGNIFICANCESingle-photon avalanche diode (SPAD) array detectors are revolutionizing fluorescence laser-scanning microscopy (FLSM). Thanks to their single-photon timing and sensitivity ability and their imaging faculty, a SPAD array detector transforms any FLSM into a super-resolution microscope, and opens a whole range of possibilities for the study of sample dynamics by means of fluorescence fluctuation spectroscopy (FFS). However, dark-noise can be a severe problem for both imaging and FFS. For imaging, the signal overcomes noise only for a relatively high illumination intensity, which can be detrimental for live-cell experiments. For FFS, the noise leads to artifacts in the correlation curves, potentially leading to wrong conclusions about the sample. We show that lowering the temperature of the detector to -15{degrees}C solves both problems

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Slenders, E., Perego, E., Buttafava, M., Tortarolo, G., Conca, E., Zappone, S., Pierzynska-Mach, A., Villa, F., Petrini, E. M., Barberis, A., Tosi, A., Vicidomini, G.. 2021-08-04. Cooled SPAD array detector for low light-dose fluorescence laser scanning microscopy. https://doi.org/10.1101/2021.08.03.454878

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Nanomechanical phenotyping uncovers a non-canonical smooth muscle-like hypercontractility program in lung squamous cell carcinoma myofibroblasts

Myofibroblast-like cancer-associated fibroblasts (myCAFs) drive the stiff, tumor-promoting microenvironment, yet their mechanical phenotype in non-small cell lung cancer (NSCLC) remains undefined. myCAFs from major NSCLC subtypes (lung adenocarcinoma (LUAD) and squamous cell carcinoma (LUSC)) were examined combining atomic force microscopy and traction force microscopy with molecular and signaling analyses. LUAD-myCAFs displayed canonical myofibroblast features, including elevated stiffness, traction forces, ROCK-MYPT1 signaling, and -SMA-rich stress fibers. Unexpectedly, LUSC-myCAFs amplified these nanomechanical features despite reduced ROCK-MYPT1 signaling and comparable -SMA levels. Instead, they exhibited a smooth muscle cell (SMC)-like contractile program characterized by enhanced SM-MHC(MYH11) expression colocalized with -SMA, ERK1/2-RLC hyperactivation, and DNA methylation reprogramming including SMC-contractility regulators. LUSC-myCAF hypercontractility was linked with reduced proliferative capacity and smaller intratumoral vessel lumens, consistent with the low CAF density and enhanced hypoxia patterns reported in LUSC. SMC markers were enriched and associated with adverse outcomes selectively in LUSC, highlighting the relevance of SMC-like myCAFs in LUSC progression. These findings unveil subtype-specific myCAF programs in NSCLC, and identify -SMA/SM-MHC(MYH11) myCAFs as key determinants of tumor mechanics, providing a rationale for the survival benefits of antihypertensive drugs targeting SMC hypercontractility. Moreover, they demonstrate that nanomechanical phenotyping can uncover translationally relevant myCAF phenotypes invisible to molecular profiling.

biophysics↗

Frequency-Dependent Structural Responses of Amyloid-β Fibrils to Terahertz Pulses: A Nonequilibrium Molecular Dynamics Study

The abnormal aggregation of amyloid proteins into fibrils is closely associated with several neurodegenerative diseases, highlighting the importance of developing effective strategies to modulate fibril structural stability. Here, we employed nonequilibrium molecular dynamics(NEMD) simulations to examine the effects of intense terahertz-to-mid-infrared pulses on three amyloid fibrils (2LMP, 2MXU, and 5OQV), focusing on the combined effects of pulse frequency and electric-field strength. Frequency scans from 0.5 to 60 THz in 0.5 THz steps revealed frequency-dependent losses of {beta}-sheet content, with several common response patterns in these fibrils. Comparisons at 2, 23, 33, and 50 THz showed that pulse-induced changes in secondary structure differed from those in high-temperature controls. Hydrogen-bond analysis showed that total hydrogen-bond counts could partially recover even as interchain hydrogen bonds continued to decrease, with distinct responses among representative chain pairs. We therefore propose a two-threshold electric-field framework for fibril disruption: Eth1 describes the onset of structural perturbation, whereas Eth2 indicates persistent structural loss after the pulse. This framework offers a testable approach for characterizing amyloid structural responses to external fields, although the underlying energy-coupling mechanisms, quantitative thresholds, and long-term recovery require further validation. These findings may provide a theoretical basis for exploring external-field-based strategies to modulate protein aggregation.

biophysics↗

Organised streaming of cerebrospinal fluid in the human third ventricle

Quasi-periodic pressure pulses associated with cardiac and respiratory activity generate reciprocating cerebrospinal fluid (CSF) motion in the human ventricles. Regular waves dominated by the cardiac cycle are overlaid with cycles of low-frequency respiratory waves, the latter to become stronger in forced breathing or even dominated by large successive flushes in NREM sleep. The present study investigates how such waves contribute to residual streaming within the human ventricles. Transient CFD simulations were performed in the third ventricle at varying parameters of frequency, stroke volume and wave-form asymmetry. Increasing the aqueduct peak Reynolds-number, either by small stroke volume and high frequency or large stroke volume at low frequency, transfers the flow from a reversible flow pattern to the formation of clear preferential pathways, alternating between the in- and outflow cycle. The resulting permanent streaming flux across the aqueduct relative to the mean oscillatory flow-rate, i.e. the dimensionless streaming ratio SR follows a rational saturation relation, SR [~] ReAq,peak/(C + ReAq,peak), demonstrating that increasing the peak aqueduct Reynolds number yields diminishing returns and bounds the relative contribution of residual inter-ventricular streaming. These findings demonstrate differences in hydrodynamic organisation in the third ventricle and highlight the importance of this organisation for intraventricular fluid exchange.

biophysics↗