bioRxiv Science⌕ Search

bioRxiv · 10.1101/2021.07.27.453890

Deep learning-based segmentation of high-resolution computed tomography image data outperforms commonly used automatic bone segmentation methods

Abstract

Segmenting bone from background is required to quantify bone architecture in computed tomography (CT) image data. A deep learning approach using convolutional neural networks (CNN) is a promising alternative method for automatic segmentation. The study objectives were to evaluate the performance of CNNs in automatic segmentation of human vertebral body (micro-CT) and femoral neck (nano-CT) data and to investigate the performance of CNNs to segment data across scanners. Scans of human L1 vertebral bodies (microCT [North Star Imaging], n=28, 53m3) and femoral necks (nano-CT [GE], n=28, 27m3) were used for evaluation. Six slices were selected for each scan and then manually segmented to create ground truth masks (Dragonfly 4.0, ORS). Two-dimensional U-Net CNNs were trained in Dragonfly 4.0 with images of the [FN] femoral necks only, [VB] vertebral bodies only, and [F+V] combined CT data. Global (i.e., Otsu and Yen) and local (i.e., Otsu r = 100) thresholding methods were applied to each dataset. Segmentation performance was evaluated using the Dice coefficient, a similarity metric of overlap. Kruskal-Wallis and Tukey-Kramer post-hoc tests were used to test for significant differences in the accuracy of segmentation methods. The FN U-Net had significantly higher Dice coefficients (i.e., better performance) than the global (Otsu: p=0.001; Yen: p=0.001) and local (Otsu [r=100]: p=0.001) thresholding methods and the VB U-Net (p=0.001) but there was no significant difference in model performance compared to the FN + VB U-net (p=0.783) on femoral neck image data. The VB U-net had significantly higher Dice coefficients than the global and local Otsu (p=0.001 for both) and FN U-Net (p=0.001) but not compared to the Yen (p=0.462) threshold or FN + VB U-net (p=0.783) on vertebral body image data. The results demonstrate that the U-net architecture outperforms common thresholding methods. Further, a network trained with bone data from a different system (i.e., different image acquisition parameters and voxel size) and a different anatomical site can perform well on unseen data. Finally, a network trained with combined datasets performed well on both datasets, indicating that a network can feasibly be trained with multiple datasets and perform well on varied image data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Patton, D. M., Henning, E. N., Goulet, R. W., Carroll, S. K., Bigelow, E. M. R., Provencher, B., Piche, N., Marsh, M., Jepsen, K. J., Bredbenner, T. L.. 2021-07-27. Deep learning-based segmentation of high-resolution computed tomography image data outperforms commonly used automatic bone segmentation methods. https://doi.org/10.1101/2021.07.27.453890

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗