bioRxiv Science⌕ Search

bioRxiv · 10.1101/2021.03.07.433990

Prospective Identification of Ictal Electroencephalogram

Abstract

BackgroundElectroencephalogram (EEG) monitoring and objective seizure identification is an essential clinical investigation for some patients with epilepsy. Accurate annotation is done through a time-consuming process by EEG specialists. Computer-assisted systems for seizure detection currently lack extensive clinical utility due to retrospective, patient-specific, and/or irreproducible studies that result in low sensitivity or high false positives in clinical tests. We aim to significantly reduce the time and resources on data annotation by demonstrating a continental generalization of seizure detection that balances sensitivity and specificity. MethodsThis is a prospective inference test of artificial intelligence on nearly 14,590 hours of adult EEG data from patients with epilepsy between 2011 and 2019 in a hospital in Sydney, Australia. The inference set includes patients with different types and frequencies of seizures across a wide range of ages and EEG recording hours. The artificial intelligence (AI) is a convolutional long short-term memory network that is trained on a USA-based dataset. The Australian set is about 16 times larger than the US training dataset with very long interictal periods (between seizures), which is way more realistic than the training set and makes our false positives highly reliable. We validated our inference model in an AI-assisted mode with a human expert arbiter and a result review panel of expert neurologists and EEG specialists on 66 sessions to demonstrate achievement of the same performance with over an order-of-magnitude reduction in time. FindingsOur inference on 1,006 EEG recording sessions on the Australian dataset achieved 76.68% with nearly 56 [0, 115] false alarms per 24 hours on average, against legacy ground-truth annotations by human experts, conducted independently over nine years. Our pilot test of 66 sessions with a human arbiter, and reviewed ground truth by a panel of experts, confirmed an identical human performance of 92.19% with an AI-assisted system, while the time requirements reduce significantly from 90 to 7.62 minutes on average. InterpretationAccurate and objective seizure counting is an important factor in epilepsy. An AI-assisted system can help improve efficiency and accuracy alongside human experts, particularly in low and middle-income countries with limited expert human resources. FundingsSOAR Fellowship from The University of Sydney, a Microsoft AI for Accessibility grant, and a Research Training Program (RTP) support provided by the Australian Government. Research in contextO_ST_ABSEvidence before this studyC_ST_ABSDuring the development of our artificial intelligence (AI) system, we did a systematic review of the scientific literature with search via PubMed for research articles published on seizure detection with the following inclusion criteria: (1) Tests or inference evaluation is conducted on large-scale clinical EEG data; (2) Generalization is attempted or potentials for generalization is considered, e.g., in commercialized tools; (3) Seizure detection delay and real-time (aka. online) operation were not considered critical in this context as long as the test was conducted on raw EEG data. Note that ICU seizure detection or portable seizure alert systems are relying on detection delay and real-time needs. Our keywords include "prospective seizure detection", "automated seizure detection", "non-patient specific seizure detection", "seizure detection on continuous EEG", and "deep learning-based seizure detection" and "machine learning-based seizure detection". We found that the only two categories of works meet our criteria: two research papers published in 2020 and works published by commercial tools developers. We cited a recent review of 89 deep learning-based seizure detection, all of which are retrospective. One work from Stanford reported seizure detection on all ages (pediatric to adult ages) using post-acquisition EEG recordings and provided an avenue for independent evaluation by providing a test on a publicly available Temple University Hospital (TUH) EEG dataset. The other work pivoted on algorithmic-assisted real-time seizure risk monitoring in continuous EEG in neonatal intensive care unit (NICU) with 128 neonates (32 with seizures) showing about 20% improvement in seizure identification over 130 neonates (38 with seizures) with no algorithmic assistance. Commercial tools we studied are Encevis (EpiScan), Besa, and Persyst. There is a recent comparative study on these tools on 81 patients. Encevis is reported as the best performing tool, and hence we provided a comparative study with Encevis ver. 1.9.2. Encevis is also the only tool that provided an avenue for comparative study on publicly available EEG data. The Stanford work, published in 2020, confirms many false positives with Persyst 13. We excluded our tests on Persyst 14 as it highly under-performed relative to Encevis. Only Stanfords work provides code availability. We compared our results with Stanfords work outcome and provided pilot test results with the Encevis (EpiScan) tool on the Australian dataset, which shows a considerably lower sensitivity. Added value of this studyTo the best of our knowledge, the current study is the first continental generalization that demonstrates the potential to achieve an expert human-level seizure recognition rate in a clinical setting and in just a fraction of time. The two datasets used in this study are recorded with different infrastructure, which adds to the independence of inference from hardware types and improves clinical utility. This is particularly important as 80% of patients with epilepsy live in low and middle-income countries with limited resources, particularly EEG specialists and neurologists. Implications of all the available evidenceOur results support the potential benefits of deep learning AI in clinical settings for seizure recognition and its contribution to significant sensitivity over available solutions. Our AI-assisted system achieves more than a ten-fold increase in time efficiency and reports identical performance to human experts for EEG interpretation with access to great neurophysiology support and auxiliary data. Our findings, particularly our tests on an available commercial tool, recommend that the evaluation, test, or inference in AI systems be performed on different datasets, with diverse infrastructures, and on large-scale and realistic sets with long interictal periods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yang, Y., Truong, N. D., Maher, C., Nikpour, A., Kavehei, O.. 2021-03-08. Prospective Identification of Ictal Electroencephalogram. https://doi.org/10.1101/2021.03.07.433990

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗