bioRxiv ScienceSearch

bioRxiv · 10.1101/2021.02.09.430396

Reconciling Inherent Interfacial Compatibility Conflict Enhances Adhesive Infiltration and Resolves Dentin Bonding Durability

Abstract

Wet bonding is a basic technique used daily in clinics for tooth-restoration fixation. However, only 50% of the bonding lasts more than 5 years and thus patients must visit the dentists repeatedly. This is attributed to the limited infiltration of adhesives into the demineralized dentin (DD) matrix during wet-bonding. Herein, we show that reconciling interfacial compatibility conflict between the DD matrix and the critical hydrophobic adhesive molecules via hydrophobizing the DD matrix enables the adhesives to thoroughly infiltrate and uniformly distribute within the DD matrix. Thus, the bonding of the hydrophobic DD matrix using commercial dentin adhesives achieves the bonding strength 2-6 times higher than that of the non-treated DD matrix. When a hydrophobic adhesive is applied on the hydrophobic DD matrix, a flawless hybrid layer is produced as observed by nanoleakage investigation. A long-term bonding strength comes up to 7.3 fold that of the control group and very importantly, with no attenuation after 12 months. This study clarifies the basic cause of poor wet-bonding durability and demonstrates a paradigm in adhesive dentistry to overcome the long-existing bonding durability problem associated with inadequate adhesive infiltration into the DD matrix. This provides a new angle of view to resolve clinical dentin bonding durability problem and will significantly promote adhesive dentistry. HighlightsO_LIInherent interfacial compatibility conflict between demineralized dentin matrix and hydrophobic molecules of dentin adhesives is the basic cause for the dentin bonding durability problem. C_LIO_LIReconciling the interfacial compatibility conflict markedly facilitates adhesive infiltration in the demineralized dentin matrix and greatly enhances bonding effectiveness. C_LIO_LIHigh interfacial compatibility produces a flawless hybrid layer and ideal bonding effectiveness and durability. C_LI Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=180 SRC="FIGDIR/small/430396v1_ufig1.gif" ALT="Figure 1"> View larger version (52K): org.highwire.dtl.DTLVardef@9687e1org.highwire.dtl.DTLVardef@b2fc79org.highwire.dtl.DTLVardef@dd7379org.highwire.dtl.DTLVardef@c8117b_HPS_FORMAT_FIGEXP M_FIG For wet bonding, poor infiltration of adhesives within the DD matrix inevitably produces numerous defects throughout the hybrid layer, which always leads to the failure of restoration. Via hydrophobizing the DD matrix, reconciling interfacial compatibility conflict between the DD matrix and the hydrophobic adhesive monomers overcomes durability problems associated with the infiltration of adhesives into the DD matrix producing a flawless hybrid layer and providing ideal bonding effectiveness and durability. C_FIG

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Luo, Q., Chen, Y., Xu, J., Shu, C., Li, Z., Zhu, W., Shen, Y., Li, X.. 2021-02-10. Reconciling Inherent Interfacial Compatibility Conflict Enhances Adhesive Infiltration and Resolves Dentin Bonding Durability. https://doi.org/10.1101/2021.02.09.430396

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering