Abstract

Evaluating and tracking wound size is a fundamental metric for the wound assessment process. Good location and size estimates can enable proper diagnosis and effective treatment. Traditionally, laboratory wound healing studies include a collection of images at uniform time intervals exhibiting the wounded area and the healing process in the test animal, often a mouse. These images are then manually observed to determine key metrics --such as wound size progress- relevant to the study. However, this task is a time-consuming and laborious process. In addition, defining the wound edge could be subjective and can vary from one individual to another even among experts. Furthermore, as our understanding of the healing process grows, so does our need to efficiently and accurately track these key factors for high throughput (e.g., over large-scale and long-term experiments). Thus, in this study, we develop a deep learning-based image analysis pipeline that aims to intake non-uniform wound images and extract relevant information such as the location of interest, wound only image crops, and wound periphery size over-time metrics. In particular, our work focuses on images of wounded laboratory mice that are used widely for translationally relevant wound studies and leverages a commonly used ring-shaped splint present in most images to predict wound size. We apply the method to a dataset that was never meant to be quantified and, thus, presents many visual challenges. Additionally, the data set was not meant for training deep learning models and so is relatively small in size with only 256 images. We compare results to that of expert measurements and demonstrate preservation of information relevant to predicting wound closure despite variability from machine-to-expert and even expert-to-expert. The proposed system resulted in high fidelity results on unseen data with minimal human intervention. Furthermore, the pipeline estimates acceptable wound sizes when less than 50% of the images are missing reference objects. Author summaryKnowledge of the wound size changes over-time allows us to observe important insights such as rate of closure, time to closure, and expansion events, which are key indicators for predicting healing status. To better perform wound measurements it is essential to utilize a technique that returns accurate and consistent results every time. Over the last years, collecting wound images is becoming easier and more popular as digital cameras and smartphones are more accessible. Commonly, scientists/clinicians trace the wound in these images manually to observe changes in the wound, which is normally a slow and labor-intensive process and also requires a trained eye. The clinical goal is to more efficiently and effectively treat wounds by employing easy to use and precise wound measurement techniques. Therefore, the objective should be devising automatic and precise wound measurement tools to be used for wound assessment. To this end, we leveraged a combination of various state-of-the-art computer vision and machine learning-based methods for developing a versatile and automatic wound assessment tool. We applied this tool to analyze the images of wound inflicted lab mice and showed that our developed tool automated the overall wound measurement process, therefore, resulting in high fidelity results without significant human intervention. Furthermore, we compared results to two expert measurements. We found variability in measurement even across experts further validating the need for a consistent approach. However, qualitative behavior, which is most important for predicting wound closure, is preserved.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Carrion, H., Jafari, M., Bagood, M. D., Yang, H.-y., Isseroff, R. R., Gomez, M.. 2020-11-13. Automatic wound detection and size estimation using deep learning algorithms. https://doi.org/10.1101/2020.11.13.275917

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

RoDPAA: A Robust Dissimilarity-Based Principal Angle Analysis Framework for Multi-View Microbiome Data Integration

Multiview microbiome studies profile the same participants across body sites or molecular layers, but integration is hampered by sparse, compositional data, modest sample sizes and methods that recognize only exact sharing. We present RoDPAA (Robust Dissimilarity-based Principal Angle Analysis), a framework that represents each view through any data-appropriate dissimilarity, such as Bray--Curtis, without log-ratio transformation or likelihood assumptions. RoDPAA aligns view-specific signal subspaces through principal angles, captures complete and partial sharing, and tests by permutation how many components are shared, using only eigendecomposition and little tuning. In Gaussian simulations, RoDPAA matched JIVE and MOFA given true ranks, ran faster and alone recovered the shared dimension in every replicate. In two inflammatory bowel disease (IBD) cohorts with sparse, zero-inflated data, Bray--Curtis-based RoDPAA recovered shared structure that was stable to prevalence filtering, whereas log-ratio-based alternatives were not. Its leading microbiome--metabolome factors, learned without disease labels, were the only ones associated with IBD.

bioinformatics↗

Deducing splicing events from transcript sets with splicelogic

Long-read RNA sequencing captures a greater proportion of full-length transcripts, enabling more accurate isoform identification, discovery of novel isoforms, and more precise differential transcript usage analysis. However, comparing transcripts, whether between conditions or between sets such as novel and annotated isoforms, yields complex isoform changes that are hard to manipulate, summarize, and visualize. This is compounded by vertical integration of some tools, where downstream analysis depends on the specific output of a particular upstream tool. To address this gap, we have developed splicelogic, an R/Bioconductor package that makes transcript-set comparisons biologically interpretable by turning them into discrete splicing events, such as exon skipping, alternative splice sites, intron retention, and alternative transcription start and end sites. We designed splicelogic to integrate easily with existing RNA-seq workflows and tools. The splicelogic functions are modular, readable, and extensible, making it easy for users to adapt core logic to their own custom scientific questions or novel splicing definitions. By obtaining interpretable splicing events from transcript changes, splicelogic enables downstream analyses, including annotation of RNA-binding protein recognition sites, alongside summary statistics and visualization. The splicelogic package is publicly available and distributed through Bioconductor.

bioinformatics↗

Contrastive Learning Improves Generalization on M2OR Olfactory Binding Dataset

Olfaction-based biosensors stand to have profound impacts in fields such as medical diagnostics, national security, and drug discovery. A promising mode of vapor phase biodetection mimics volatile organic compound-olfactory receptor (VOC-OR) interactions with target-specific protein or peptide probes; however, lack of experimental coverage remains a core bottleneck. Current computational approaches aim to improve prediction of VOC-OR binding to reduce experimental burden, and current machine learning approaches fail to demonstrate a level of generalization that addresses current engineering challenges. Here, using the Molecular to Olfactory Dataset (M2OR) and Insect Olfactory Binding Protein Database (iOBPdb) datasets, data partitioning methods and their performance are evaluated on a neural network and contrastive learning framework on such VOC-OR binding datasets, varying: model training, architecture, and structure of the input data distribution. It was found that holding out certain chemical or proteomic motifs from the training data diminished model performance with a two layer neural network model. The model was able to generalize to state of the art performance (0.88 AUCROC) on every data split by applying a contrastive learning objective defined by shared molecular constituents and a stochastic sampler. This suggests the contrastive objective provides a strong inductive bias for neural networks to predict novel VOC-OR pairs. These findings highlight that model performance on pairwise biological interaction datasets can be inflated through identity leakage from constituent overlap, and emphasize the need for more robust evaluation protocols. Furthermore, we show contrastive regularization mitigates dataset degeneracy through enforcement of compatibility in the models latent geometry that may extend to other binder target-datasets where identity leakage confounds evaluation.

bioinformatics↗