bioRxiv ScienceSearch

bioRxiv · 10.1101/2020.03.26.009837

The technique of articular rabbit cartilage roughness measurement and analysis of the effect of PRP in knee osteoarthritis therapy using atomic force microscopy

Abstract

Hyaline cartilage undergoes degenerative-dystrophic changes with subsequent involvement of the subchondral bone. The purpose of this study was developing a new AFM-based method to articular rabbit cartilage roughness measurement, followed by an investigation of whether platelet-rich plasma therapy of knee osteoarthritis has a positive impact on mechanical properties of rabbit cartilage. The rabbits were randomly divided into two groups: the control group (N=6) and the patients (N=12). Saline (0.5 ml) and 10% surgical talc solution were injected into the right knee of 12 rabbits to induce osteoarthritis. Six rabbits underwent PRP therapy, while the other six did not receive treatment. The mechanical properties and the submicron surface morphology rabbit hyaline cartilage were investigated using atomic force microscopy (AFM). In the group of specimens worn out by induced osteoarthritis, the maximum arithmetic average of absolute values (Ra) change was a 23% increase; the maximum peak height (Rp) increased by over 100%, while the mean spacing between local peaks (S) increased by 26%, compared to healthy rabbit cartilage (p<0.05). In the group of specimens worn out by induced osteoarthritis and cured with PRP therapy, Ra increased by 13%; Rp increased by 33%, while S decreased by 77%, compared to healthy rabbit cartilage (p<0.05). It was found that the mechanical properties of hyaline cartilage deteriorate under the influence of simulated osteoarthritis. The results of PRP treatment in rabbits may constitute a step forward to further relevant studies involving OA patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pauk, J., Karev, D., Karev, B., Ihnatouski, M.. 2020-03-26. The technique of articular rabbit cartilage roughness measurement and analysis of the effect of PRP in knee osteoarthritis therapy using atomic force microscopy. https://doi.org/10.1101/2020.03.26.009837

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering