bioRxiv ScienceSearch

bioRxiv · 10.1101/2020.01.21.913707

What causes different coronal curve patterns in idiopathic scoliosis?

Abstract

BackgroundAdolescent idiopathic scoliosis (AIS) is a three-dimensional deformity of the spinal column in otherwise healthy adolescents. The underlying mechanisms associated with the spinal deformity development have been explored which delineated the role of the sagittal curvature of the spine. The patterns of the spinal deformity vary between the AIS patients as shown in several classification systems. It remains to further investigate how variations in sagittal profiles result in different coronal plane deformities in AIS and how these deformation patterns are intrinsically different. MethodsA total of 71 Lenke 1 and 52 Lenke 5 AIS patients were included retrospectively. The 3D models of the spine were generated from biplanar radiographs to calculate the clinical spinal parameters, vertebral axial rotations, and the 3D centerline of the spinal curvature. A classification based on the centerlines axial plane projection was developed. The 3D curvature of the centerline was calculated at each point. A 2D elastic rod finite element model (FEM) of the sagittal spinal curvature for each axial subtype was developed to calculate the 3D deformity of the spine under gravity and axial torsion. Differences in the axial clusters clinical parameters, curvature of the spine, and the deformation patterns of the FEM were compared. The characteristics of the sagittal curvature of these axial clusters were determined. ResultsLenke1 was divided into two axial groups (I and II) whereas the Lenke 5 cohort all had the same axial projection pattern (loop shape). T5-T12 kyphosis was significantly different between Lenke1-Group I and the other two groups, p=0.04. The vertebral rotation in both Lenke1-Group I and Lenke 5 had only one maximum value and the FEM deformed in a loop shaped whereas Lenke1-group II showed two maximum values for vertebral rotation and the FEM of the centerline deformed in a lemniscate shape. The ratio of the spinal arc lengths above and below the sagittal inflection points for Lenke1-Groups I and II and Lenke 5 were 0.52, 1.16, and 3.24, respectively. ConclusionVariations in the axial plane projection of the curve were observed within Lenke types. Lenke 1- Group I and Lenke 5 showed similar 3D curve characteristics suggesting one 3D curve whereas Lenke1-Group II, with two 3D curves, behaved differently. The length of the spinal arcs above and below the sagittal inflection point related to the patterns of axial deformity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pasha, S.. 2020-01-21. What causes different coronal curve patterns in idiopathic scoliosis?. https://doi.org/10.1101/2020.01.21.913707

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering