bioRxiv Science⌕ Search

bioRxiv · 10.1101/180844

Intra-voxel incoherent motion magnetic resonance imaging of the living human fetus: the technique and within-subject reproducibility

Abstract

Our purpose was to test the within-subject repeatability of the perfusion fraction, diffusion coefficient and pseudo diffusion coefficient measurements in various fetal organs and in the placenta based on the intra-voxel incoherent motion imaging principle. In utero diffusion-weighted magnetic resonance imaging was performed on 1.5T and 3.0T clinical scanners with b-factors ranging from 0 to 900 s/mm2 in 16 steps and a tetrahedral diffusion-weighting encoding scheme. Data from 16 pregnant women (maternal age: 34 {+/-} 4.9 years, range: 24.6 -40.8) were included in this pilot study. For 15 cases, IVIM was repeated (maternal age: 33.7 {+/-} 5.2 years, range: 24.6 - 40.8). A bi-exponential model was fitted on the volume-averaged diffusion values and the perfusion fraction (f), diffusion coefficient (d) and pseudo diffusion coefficient (D*) were calculated. Within-subject repeatability was given as the test-retest variability of the IVIM parameters in the fetal frontal cortex, frontal white matter, cerebellum, lungs, kidneys, liver and in the placenta. An in-house developed image processing script was utilized to remove the image frames with excessive motion, and to perform motion correction by using non-linear freeform deformations. For the fetal lungs, liver and the placenta, within-subject variability ranged from 14.4% to 20.4% for f, 12.2% to 14.1% for d and 16.8% to 25.3% for D*. The diffusion coefficients of the investigated brain regions were moderately to highly reproducible (4.8% to 15.2%), however, f and D* showed inferior reproducibility compared to corresponding measures derived for the lungs, liver and placenta. The IVIM-based parameters of the fetal kidney were revealed to be highly variable across scans. Our results indicate that in utero intra-voxel incoherent motion magnetic resonance imaging potentially provides a novel method for examining microvascular perfusion and diffusion in the developing human fetus. The reproducible quantification of the perfusion and diffusion parameters depend greatly upon data quality, fetal and maternal movements, and image post processing to detect and remove corrupted data before calculating the IVIM model.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jakab, A., Tuura, R., Kottke, R., Kellenberger, C., Scheer, I.. 2017-08-25. Intra-voxel incoherent motion magnetic resonance imaging of the living human fetus: the technique and within-subject reproducibility. https://doi.org/10.1101/180844

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Deducing splicing events from transcript sets with splicelogic

Long-read RNA sequencing captures a greater proportion of full-length transcripts, enabling more accurate isoform identification, discovery of novel isoforms, and more precise differential transcript usage analysis. However, comparing transcripts, whether between conditions or between sets such as novel and annotated isoforms, yields complex isoform changes that are hard to manipulate, summarize, and visualize. This is compounded by vertical integration of some tools, where downstream analysis depends on the specific output of a particular upstream tool. To address this gap, we have developed splicelogic, an R/Bioconductor package that makes transcript-set comparisons biologically interpretable by turning them into discrete splicing events, such as exon skipping, alternative splice sites, intron retention, and alternative transcription start and end sites. We designed splicelogic to integrate easily with existing RNA-seq workflows and tools. The splicelogic functions are modular, readable, and extensible, making it easy for users to adapt core logic to their own custom scientific questions or novel splicing definitions. By obtaining interpretable splicing events from transcript changes, splicelogic enables downstream analyses, including annotation of RNA-binding protein recognition sites, alongside summary statistics and visualization. The splicelogic package is publicly available and distributed through Bioconductor.

bioinformatics↗

Contrastive Learning Improves Generalization on M2OR Olfactory Binding Dataset

Olfaction-based biosensors stand to have profound impacts in fields such as medical diagnostics, national security, and drug discovery. A promising mode of vapor phase biodetection mimics volatile organic compound-olfactory receptor (VOC-OR) interactions with target-specific protein or peptide probes; however, lack of experimental coverage remains a core bottleneck. Current computational approaches aim to improve prediction of VOC-OR binding to reduce experimental burden, and current machine learning approaches fail to demonstrate a level of generalization that addresses current engineering challenges. Here, using the Molecular to Olfactory Dataset (M2OR) and Insect Olfactory Binding Protein Database (iOBPdb) datasets, data partitioning methods and their performance are evaluated on a neural network and contrastive learning framework on such VOC-OR binding datasets, varying: model training, architecture, and structure of the input data distribution. It was found that holding out certain chemical or proteomic motifs from the training data diminished model performance with a two layer neural network model. The model was able to generalize to state of the art performance (0.88 AUCROC) on every data split by applying a contrastive learning objective defined by shared molecular constituents and a stochastic sampler. This suggests the contrastive objective provides a strong inductive bias for neural networks to predict novel VOC-OR pairs. These findings highlight that model performance on pairwise biological interaction datasets can be inflated through identity leakage from constituent overlap, and emphasize the need for more robust evaluation protocols. Furthermore, we show contrastive regularization mitigates dataset degeneracy through enforcement of compatibility in the models latent geometry that may extend to other binder target-datasets where identity leakage confounds evaluation.

bioinformatics↗

Plate design confounds donor variation and model evaluation in single-cell perturbation screens

Single-cell screens of immune cells from many donors are used to study why individuals respond differently and to benchmark response models. Each donor-perturbation combination typically occupies one well, controls are grouped, and donors share one layout, so technical effects can look biological. Using a 90-cytokine screen, two compound screens, four cohorts and simulations, we show that well effects explain most replicate-control variation in abundant cell types, controls carry a shared offset, and identical control wells differ by hundreds of differentially expressed genes at a standard threshold, about as many as two receptor-negative proteins do. Negative controls, design-aware estimators and perturbation-specific evaluation change the interpretation of four recent analyses. A deep-learning model that scores below a perturbation-agnostic predictor under standard evaluation outperforms a simple baseline on perturbation-specific differences in two of three cell types (significantly in one with stricter controls), but predicts less well the component shared with inert wells.

bioinformatics↗