bioRxiv Science⌕ Search

bioRxiv · 10.1101/162396

Rapid Detection of Norovirus Using Paper-based Microfluidic Device

Abstract

Noroviruses (NoV) are the leading cause of outbreak of acute gastroenteritis worldwide. A substantial effort has been made in the development of analytical devices for rapid and sensitive food safety monitoring via the detection of foodborne bacteria, viruses and parasites. Conventional analytical approaches for noroviruses suffer from some critical weaknesses: labor-intensive, time-consuming, and relatively low sensitivity. In this study, we developed a rapid and highly sensitive biosensor towards point-of-care device for noroviruses based on 6-carboxyfluorescein (6-FAM) labeled aptamer and nanomaterials, multi-walled carbon nanotubes (MWCNTs) and graphene oxide (GO). In an assay, the fluorescence of 6-FAM labeled aptamer was quenched by MWCNTs or GO via fluorescence resonance energy transfer (FRET). In the presence of norovirus, the fluorescence would be recovered due to the release of the 6-FAM labeled aptamer from MWCNTs or GO. An easy-to-make paper-based microfluidic platform made by nitrocellulose membrane was used to conduct the assay. The quantitative detection of norovirus virus-like particles (NoV VLPs) was successfully performed. A linear range of 0-12.9 g/mL with a detection limit of 40 pM and 30 pM was achieved for the MWCNTs and GO based paper sensors, respectively. The results suggested the developed paper-based microfluidic device is simple, cost-effective and holds the potential of rapid in situ visual determination for noroviruses with remarkable sensitivity and specificity, which provides a new way for early identification of NoV and thereby an early intervention for preventing the spread of an outbreak.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Weng, X., Neethirajan, S.. 2017-07-12. Rapid Detection of Norovirus Using Paper-based Microfluidic Device. https://doi.org/10.1101/162396

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

N-GLYcanyzer monitoring of a microperfusion process reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution

Controlling monoclonal antibody (mAb) N-glycosylation as a critical quality attribute (CQA) remains challenging in continuous and intensified biomanufacturing, where conventional end-point analyses obscure dynamic pathway responses. Here, we deployed the N-GLYcanyzer process analytical technology (PAT) for automated monitoring of a microperfusion process that reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution across a 20-day culture duration of Chinese Hamster Ovary (CHO) cells in a ~2 mL scale-down microbioreactor perfusion platform. Using offline PAT assays combined with our integrated at-line PAT workflow, we systematically screened six perfusion process parameters: carbon source, viable cell density (VCD), perfusion rate, temperature, and pH. While nutrient limitation and thermal/acidic stress significantly disrupted N-glycans maturation, notably triggering high-mannose (Man5) accumulation and severe productivity penalties under pH 6.7 and 39 {degrees}C operation, targeted feed supplementation with galactose and MnCl2 consistently shifted glycoform profiles away from G0F toward galactosylated species (G1F, G1F', G2F). Crucially, coupling this combined feed strategy with an intensified perfusion rate (1.2 VVD) achieved a sustained, desired galactosylation shift without a productivity cost. These findings demonstrate that nutrient feed composition and perfusion rate are primary levers for steering continuous intensified microperfusion processes for biologics production with desired N-glycoform states and highlight the utility of automated at-line PAT like N-GLYcanyzer for enabling real-time attribute-based control in continuous biomanufacturing.

bioengineering↗

Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

The output of a wearable cortisol sensor drifts over days for reasons unrelated to cortisol, so a calibration made on the first day soon stops being valid. In our differential organic electrochemical transistor, a PEDOT:PSS transistor coated with a molecularly imprinted polymer (MIP) for cortisol is paired with one coated with a non-imprinted polymer (NIP) of the same composition, and the NIP response is subtracted. Over four calibrations in artificial sweat across 14 days, the response of the MIP alone shifted by 15% to 22% of its range on day 1, whereas the differential output shifted by 1% to 10%, and the variation between days at 1 to 10nM fell by 65% to 70% on average for individual pairs. In sweat from one participant, read against the calibration from day 1, both outputs tracked the direction of visible changes in salivary cortisol, while the MIP alone diverged from the differential output, consistent with the laboratory drift.

bioengineering↗

A cytotoxicity dataset for data-driven design of ionizable lipid nanoparticles

Ionizable lipid nanoparticles (LNPs) are widely used to deliver nucleic acid therapeutics, but the design of safe LNPs remains challenging due to the complex activity relationships among structure, composition, and physicochemical properties. Here, we present a curated dataset, the Lipid Nanoparticle Cytotoxicity Database (LNPCD), which aggregates 1,413 LNP cytotoxicity measurements across 1,288 unique ionizable lipids drawn from 11 high-throughput combinatorial studies. Lipid structures were generated computationally from the published libraries and manually verified against the original publications. Each record pairs a machine-readable SMILES representation of the ionizable lipid with its measured viability endpoint and the associated experimental descriptors, including cell line, dose, and cargo type. The dataset provides a traceable resource for examining how ionizable lipid structure and experimental conditions relate to in vitro cell viability, and for developing and evaluating computational models of lipid nanoparticle cytotoxicity.

bioengineering↗