bioRxiv Science⌕ Search

Biology subjects

de Greef, T. F. A.

Publications and source records attributed to de Greef, T. F. A..

7 recordsLinked to original sources

DNA-GUARD: molecular access control as a physical security layer for DNA data storage

DNA data storage offers exceptional density and millennial-scale stability, with advances in encoding schemes and reduced synthesis costs making large-scale archiving increasingly viable. However, while efforts have focused on reliable data retrieval, securing DNA-encoded information against unauthorized access remains largely unexplored. Here, we introduce DNA-GUARD (DNA Gated Unlocking and Access Restriction of Data), a molecular-level access control system that physically restricts data retrieval rather than relying on computational encryption. DNA-GUARD integrates with PCR-based random access by selectively blocking amplification of protected sequences. Chemically modified "locker strands" outcompete PCR primers and block polymerase extension through 3 inverted dT modifications, preventing amplification of key sequences required for file decoding. To restore access, complementary "password strands" tethered to magnetic particles sequester locker strands, enabling their removal and restoring data access. We demonstrate DNA-GUARDs scalability from 550-byte to 1-MB files without performance loss, orthogonal control of multiple files within mixed libraries, and reliable repeated locking-unlocking cycles. This approach enables physical access control compatible with established DNA storage workflows, providing a foundation for secure archival storage with implications for molecular information security that complements cryptographic data protection methods.

synthetic biology↗

Engineered microRNA feedback circuits enable tunable and autonomous control of synthetic receptor activity

Synthetic receptors are powerful tools for cellular engineering, yet their utility is often constrained by constitutive activity and the absence of natural feedback mechanisms that maintain cellular homeostasis. To address this, we engineered an autonomous regulatory circuit for synthetic Notch (synNotch) receptor activation using an orthogonal microRNA (miRNA)-mediated negative feedback mechanism in mammalian cells. Specifically, synNotch activation induces the expression of a synthetic miRNA that targets complementary sites engineered into the synNotch transcript, resulting in a self-limiting feedback loop. We demonstrate that synNotch repression positively correlates with the number of miRNA target sites integrated into the receptor transcript, enabling tunable control of receptor expression. Furthermore, flow cytometry and live-cell imaging analyses revealed effective suppression of synNotch expression following activation. Downstream target gene expression peaked at approximately 48 hours post-activation before gradually declining as the feedback circuit engaged. This approach achieves autonomous synthetic receptor regulation--eliminating the need for external intervention--and enables tunable response dynamics through rational circuit design. Our miRNA feedback strategy provides a generalizable platform for engineering self-regulating synthetic receptor systems with improved control and predictability for cellular engineering applications.

synthetic biology↗

Unveiling DNA Origami Interaction Dynamics on Living Cell Surfaces by Single Particle Tracking

Due to the unique spatial addressability of DNA origami, targeting ligands (e.g. aptamers or antibodies) can be specifically positioned onto the surface of the nanostructure, constituting an essential tool for studying ligand-receptor interactions at the cell surface. While the design and ligand incorporation into DNA origami nanostructures are well-established, the study of cell surface interaction dynamics is still in the explorative phase, where in depth fundamental understanding on the molecular interactions remains underexplored. This study uniquely captures real-time encounters between DNA origami and cells in-situ using single particle tracking (SPT). Here, we functionalized DNA nanorods (NRs) with antibodies or aptamers specific to the epidermal growth factor receptor (EGFR) and used them to target EGFR-overexpressing cancer cells. SPT data revealed that ligand coated NRs selectively bound to the receptors expressed in target cancer cells, while non-functionalized NRs only display negligible cell interactions. Furthermore, we explored the effect of ligand density on the DNA origami, which revealed that aptamer-decorated NRs exhibit non-linear binding characteristics, whereas this effect in antibody-decorated NRs was less pronounced. This study provides new mechanistic insights into the fundamental understanding of DNA origami behaviour at the cell interface, with unprecedented spatiotemporal resolution, aiding the rational design of ligand-targeted DNA origami for biomedical applications.

bioengineering↗

Determinants of ligand-functionalized DNA nanostructure-cell interactions

Synthesis of ligand-functionalized nanomaterials with control over size, shape and ligand orientation, facilitates the design of tailored nanomedicines for therapeutic purposes. DNA nanotechnology has emerged as a powerful tool to rationally construct two- and three-dimensional nanostructures, enabling site-specific incorporation of protein ligands with control over stoichiometry and orientation. To efficiently target cell surface receptors, exploration of the parameters that modulate cellular accessibility of these nanostructures is essential. In this study we systematically investigate tunable design parameters of antibody-functionalized DNA nanostructures binding to therapeutically relevant receptors. We show that, although the native affinity of antibody-functionalized DNA nanostructures remains unaltered, the absolute number of bound surface receptors is lower compared to soluble antibodies and is mainly governed by nanostructure size and DNA handle location. The obtained results provide key insights in the ability of ligand-functionalized DNA nanostructures to bind surface receptors and yields design rules for optimal cellular targeting.

synthetic biology↗

Cell-Free Characterization of Coherent Feed-Forward Loop-Based Synthetic Genetic Circuit

Regulatory pathways inside living cells employ feed-forward architectures to fulfill essential signal processing functions that aide in the interpretation of various types of inputs through noise-filtering, fold-change detection and adaptation. Although it has been demonstrated computationally that a coherent feed-forward loop (CFFL) can function as noise filter, a property essential to decoding complex temporal signals, this motif has not been extensively characterized experimentally or integrated into larger networks. Here we use post-transcriptional regulation to implement and characterize a synthetic CFFL in an Escherichia coli cell-free transcription-translation system and build larger composite feed-forward architectures. We employ microfluidic flow reactors to probe the response of the CFFL circuit using both persistent and short, noise-like inputs and analyze the influence of different circuit components on the steady-state and dynamics of the output. We demonstrate that our synthetic CFFL implementation can reliably repress background activity compared to a reference circuit, but displays low potential as a temporal filter, and validate these findings using a computational model. Our results offer practical insight into the putative noise-filtering behavior of CFFLs and show that this motif can be used to mitigate leakage and increase the fold-change of the output of synthetic genetic circuits.

synthetic biology↗

RAPPID: a platform of ratiometric bioluminescent sensors for homogeneous immunoassays

Heterogeneous immunoassays such as ELISA have become indispensable in modern bioanalysis, yet translation into easy-to-use point-of-care assays is hindered by their dependence on external calibration and multiple washing and incubation steps. Here, we introduce RAPPID (Ratiometric Plug-and-Play Immunodiagnostics), a "mix-and-measure" homogeneous immunoassay platform that combines highly specific antibody-based detection with a ratiometric bioluminescent readout that can be detected using a basic digital camera. The concept entails analyte-induced complementation of split NanoLuc luciferase fragments, photoconjugated to an antibody sandwich pair via protein G adapters. We also introduce the use of a calibrator luciferase that provides a robust ratiometric signal, allowing direct in-sample calibration and quantitative measurements in complex media such as blood plasma. We developed RAPPID sensors that allow low-picomolar detection of several protein biomarkers, anti-drug antibodies, therapeutic antibodies, and both SARS-CoV-2 spike protein and anti-SARS-CoV-2 antibodies. RAPPID combines ratiometric bioluminescent detection with antibody-based target recognition into an easy-to-implement standardized workflow, and therefore represents an attractive, fast, and low-cost alternative to traditional immunoassays, both in an academic setting and in clinical laboratories for point-of-care applications.

bioengineering↗

Minimally Complex Nucleic Acid Feedback Control Systems for First Experimental Implementations

Chemical reaction networks based on catalysis, degradation, and annihilation may be used as building blocks to construct a variety of dynamical and feedback control systems in Synthetic Biology. DNA strand-displacement, which is based on DNA hybridisation programmed using Watson-Crick base pairing, is an effective primitive to implement such reactions experimentally. However, experimental construction, validation and scale-up of nucleic acid control systems is still significantly lagging theoretical developments, due to several technical challenges, such as leakage, crosstalk, and toehold sequence design. To help the progress towards experimental implementation, we provide here designs representing two fundamental classes of reference tracking control circuits (integral and state-feedback control), for which the complexity of the chemical reactions required for implementation has been minimised. The supplied minimally complex control circuits should be ideal candidates for first experimental validations of nucleic acid controllers.

synthetic biology↗