Integrated Short-TE and Hadamard-edited Multi-Sequence (ISTHMUS) for Advanced MRS

BackgroundTo examine data quality and reproducibility using ISTHMUS, which has been implemented as the standardized MR spectroscopy sequence for the multi-site Healthy Brain and Child Development (HBCD) study. MethodsISTHMUS is the consecutive acquisition of short-TE PRESS (32 transients) and long-TE HERCULES (224 transients) data with dual-TE water reference scans. Voxels were positioned in the centrum semiovale, dorsal anterior cingulate cortex, posterior cingulate cortex and bilateral thalamus regions. After acquisition, ISTHMUS data were separated into the PRESS and HERCULES portions for analysis and modeled separately using Osprey. In vivo experiments were performed in 10 healthy volunteers (6 female; 29.5{+/-}6.6 years). Each volunteer underwent two scans on the same day. Differences in metabolite measurements were examined. T2 correction based on the dual-TE water integrals were compared with: 1) T2 correction based the default white matter and gray matter T2 reference values in Osprey; 2) shorter WM and GM T2 values from recent literature; and 3) reduced CSF fractions. ResultsNo significant difference in linewidth was observed between PRESS and HERCULES. Bilateral thalamus spectra had produced significantly higher (p<0.001) linewidth compared to the other three regions. Linewidth measurements were similar between scans, with scan-to-scan differences under 1 Hz for most subjects. Paired t-tests indicated a significant difference only in PRESS NAAG between the two thalamus scans (p=0.002). T2 correction based on shorter T2 values showed better agreement to the dual-TE water integral ratio. ConclusionsISTHMUS facilitated and standardized acquisition and post-processing and reduced operator workload to eliminate potential human error. HighlightsO_LIISTHMUS has been implemented into the HBCD study protocol. C_LIO_LIIt acquires both short-TE and Hadamard-edited transients. C_LIO_LIISTHMUS reduces operator workload. C_LIO_LIISTHMUS potentially allows improved T2 relaxation correction C_LI

bioengineering↗

Simultaneous multi-transient linear-combination modeling of MRS data improves uncertainty estimation

PurposeThe interest in applying and modeling dynamic MRS has recently grown. 2D modeling yields advantages for the precision of metabolite estimation in interrelated MRS data. However, it is unknown whether including all transients simultaneously in a 2D model without averaging (presuming a stable signal) performs similarly to 1D modeling of the averaged spectrum. Therefore, we systematically investigated the accuracy, precision, and uncertainty estimation of both described model approaches. MethodsMonte Carlo simulations of synthetic MRS data were used to compare the accuracy and uncertainty estimation of simultaneous 2D multi-transient LCM with 1D-LCM of the average. 2,500 datasets per condition with different noise representations of a 64-transient MRS experiment at 6 signal-to-noise levels for two separate spin systems (scyllo-inositol and GABA) were analyzed. Additional datasets with different levels of noise correlation were also analyzed. Modeling accuracy was assessed by determining the relative bias of the estimated amplitudes against the ground truth, and modeling precision was determined by standard deviations and Cramer-Rao Lower Bounds (CRLB). ResultsAmplitude estimates for 1D- and 2D-LCM agreed well and showed similar level of bias compared to the ground truth. Estimated CRLBs agreed well between both models and with ground truth CRLBs. For correlated noise the estimated CRLBs increased with the correlation strength for the 1D-LCM but remained stable for the 2D-LCM. ConclusionOur results indicate that the model performance of 2D multi-transient LCM is similar to averaged 1D-LCM. This validation on a simplified scenario serves as necessary basis for further applications of 2D modeling.

neuroscience↗

The AGNOSTIC MRS Benchmark Dataset: Deep Learning for Out-of-voxel Artifacts

Neural networks are potentially valuable for many of the challenges associated with MRS data. The purpose of this manuscript is to describe the AGNOSTIC dataset, which contains 259,200 synthetic 1H MRS examples for training and testing neural networks. AGNOSTIC was created using 270 basis sets that were simulated across 18 field strengths and 15 echo times. The synthetic examples were produced to resemble in vivo brain data with combinations of metabolite, macromolecule, residual water signals, and noise. To demonstrate the utility, we apply AGNOSTIC to train two Convolutional Neural Networks (CNNs) to address out-of-voxel (OOV) echoes. A Detection Network was trained to identify the point-wise presence of OOV echoes, providing proof of concept for real-time detection. A Prediction Network was trained to reconstruct OOV echoes, allowing subtraction during post-processing. Complex OOV signals were mixed into 85% of synthetic examples to train two separate CNNs for the detection and prediction of OOV signals. AGNOSTIC is available through Dryad and all Python 3 code is available through GitHub. The Detection network was shown to perform well, identifying 95% of OOV echoes. Traditional modeling of these detected OOV signals was evaluated and may prove to be an effective method during linear-combination modeling. The Prediction Network greatly reduces OOV echoes within FIDs and achieved a median log10 normed-MSE of -1.79, an improvement of almost two orders of magnitude.

neuroscience↗

Impact of acquisition and modeling parameters on test-retest reproducibility of edited GABA+

Literature values for within-subject test-retest reproducibility of gamma-aminobutyric acid (GABA), measured with edited magnetic resonance spectroscopy (MRS), vary widely. Reasons for this variation remain unclear. Here we tested whether sequence complexity (two-experiment MEGA-PRESS versus four-experiment HERMES), editing pulse duration (14 versus 20 ms), scanner frequency drift (interleaved water referencing (IWR) turned ON versus OFF), and linear combination modeling variations (three different co-edited macromolecule models and 0.55 versus 0.4 ppm spline baseline knot spacing) affected the within-subject coefficient of variation of GABA + macromolecules (GABA+). We collected edited MRS data from the dorsal anterior cingulate cortex from 20 participants (30.8 {+/-} 9.5 years; 10 males). Test and retest scans were separated by removing the participant from the scanner for 5-10 minutes. Each acquisition consisted of two MEGA-PRESS and two HERMES sequences with editing pulse durations of 14 and 20 ms (referred to here as: MEGA-14, MEGA-20, HERMES-14, and HERMES-20; all TE = 80 ms, 224 averages). Reproducibility did not consistently differ for MEGA-PRESS compared with HERMES or for 14 compared with 20 ms editing pulses. A composite model of the 0.9 and 3 ppm macromolecules (particularly for HERMES) and sparser (0.55 compared with 0.4 ppm) spline baseline knot spacing yielded generally better test-retest reproducibility for GABA+. Replicating our prior results, linear combination modeling in Osprey compared with simple peak fitting in Gannet resulted in substantially better test-retest reproducibility. These results highlight the importance of model selection for edited MRS studies of GABA+, particularly for clinical studies which focus on individual patient differences in GABA+ or changes following an intervention.

neuroscience↗

Image Downsampling Expedited Adaptive Least-squares (IDEAL) fitting improves intravoxel incoherent motion (IVIM) analysis in the human kidney

PurposeTo improve the reliability of intravoxel incoherent motion model (IVIM) parameter estimation for the diffusion-weighted imaging in the kidney using a novel Image Downsampling Expedited Adaptive Least-squares (IDEAL) approach. MethodsThe robustness of IDEAL was investigated using simulated diffusion-weighted MRI data corrupted with different levels of Rician noise. Subsequently, the performance of the proposed method was tested by fitting bi- and triexponential IVIM model to in vivo renal DWI data acquired on a clinical 3 Tesla MRI scanner and compared to conventional approaches (Fixed D* and Segmented fitting). ResultsThe numerical simulations demonstrated that the IDEAL algorithm provides robust estimates of the IVIM parameters in the presence of noise as indicated by relatively low absolute percentage bias (sMdPB [%]) and normalized root-mean-square error (RMSE [%]). The analysis of the in vivo data showed that the IDEAL-based IVIM parameter maps were less noisy and more visually appealing than those obtained using the Fixed D* and Segmented methods. Further, the use of IDEAL for the triexponential IVIM modelling resulted in reduced cortical and medullary coefficients of variation (CVs) for all IVIM parameters when compared with Fixed D*, reflecting greater accuracy of this method. ConclusionThe proposed fitting algorithm yields more robust IVIM parameter estimates and is less susceptible to poor SNR than the conventional fitting approaches. Thus, the IDEAL approach has the potential to improve the reliability of renal DW-MRI analysis for clinical applications.

biophysics↗

Neurometabolic timecourse of healthy aging

PurposeThe neurometabolic timecourse of healthy aging is not well-established, in part due to diversity of quantification methodology. In this study, a large structured cross-sectional cohort of male and female subjects throughout adulthood was recruited to investigate neurometabolic changes as a function of age, using consensus-recommended magnetic resonance spectroscopy quantification methods. Methods102 healthy volunteers, with approximately equal numbers of male and female participants in each decade of age from the 20s, 30s, 40s, 50s, and 60s, were recruited with IRB approval. MR spectroscopic data were acquired on a 3T MRI scanner. Metabolite spectra were acquired using PRESS localization (TE = 30 ms; 96 transients) in the centrum semiovale (CSO) and posterior cingulate cortex (PCC). Water-suppressed spectra were modeled using the Osprey algorithm, employing a basis set of 18 simulated metabolite basis functions and a cohort-mean measured macromolecular spectrum. Pearson correlations were conducted to assess relationships between metabolite concentrations and age for each voxel; paired t-tests were run to determine whether metabolite concentrations differed between the PCC and CSO. ResultsTwo datasets were excluded (1 ethanol; 1 unacceptably large lipid signal). Statistically significant age-by-metabolite correlations were seen for tCr (R2=0.36; p<0.001), tCho (R2=0.11; p<0.001), sI (R2=0.11; p=0.004), and mI (R2=0.10; p<0.001) in the CSO, and tCr (R2=0.15; p<0.001), tCho (R2=0.11; p<0.001), and GABA (R2=0.11; p=0.003) in the PCC. No significant correlations were seen between tNAA, NAA, GSH, Glx or Glu and age in either region (all p>0.25). Levels of sI were significantly higher in the PCC in female subjects (p<0.001) than in male subjects. There was a significant positive correlation between linewidth and age. ConclusionThe results indicated age correlations for tCho, tCr, sI, and mI in CSO and for tCr, tCho and GABA in PCC, while no age-related changes were found for NAA, tNAA, GSH, Glu or Glx. Our results provide a normative foundation for future work investigating the neurometabolic time course of healthy aging using MRS. HighlightsO_LIA large structured cross-sectional cohort of neurometabolic aging dataset is presented; C_LIO_LIAge correlations were observed for tCho, tCr, sI, and mI in CSO and for tCr, tCho and GABA in PCC; C_LIO_LINo age correlations were found for NAA, tNAA, GSH, Glu or Glx in either region. C_LI

neuroscience↗

Importance of linear combination modeling for quantification of Glutathione and GABA levels using Hadamard-edited MRS

PurposeTwo main approaches are used for spectral analysis of edited data: simple peak fitting and linear combination modeling (LCM) with a simulated basis set. Recent consensus recommended LCM as the method of choice for the spectral analysis of edited data. The aim of this study is to compare the performance of simple peak fitting and LCM in a test-retest dataset, hypothesizing that the more sophisticated LCM approach will improve quantification of HERMES data compared with simple peak fitting. MethodsA test-retest dataset was re-analyzed using Gannet (simple peak fitting) and Osprey (LCM). These data were obtained from the dorsal anterior cingulate cortex of twelve healthy volunteers, with TE 80 ms for HERMES and TE 120 ms for MEGA-PRESS of glutathione (GSH). Within-subject coefficients of variance (CVs) were calculated to quantify between-scan reproducibility of each metabolite estimate. ResultsThe reproducibility of HERMES GSH estimates was substantially improved using LCM compared to simple peak fitting, from a CV of 19.0% to 9.9%. For MEGA-PRESS data, the GSH reproducibility was similar using LCM and simple peak fitting, with CVs of 7.3% and 8.8% respectively. ConclusionLinear combination modeling with simulated basis functions substantially improves the reproducibility of GSH quantification for HERMES data.

biophysics↗

Comparison of algorithms for linear-combination modelling of short-echo-time magnetic resonance spectra

Short-TE proton MRS is used to study metabolism in the human brain. Common analysis methods model the data as linear combination of metabolite basis spectra. This large-scale multi-site study compares the levels of the four major metabolite complexes in short-TE spectra estimated by three linear-combination modelling (LCM) algorithms. 277 medial parietal lobe short-TE PRESS spectra (TE = 35 ms) from a recent 3T multi-site study were pre-processed with the Osprey software. The resulting spectra were modelled with Osprey, Tarquin and LCModel, using the same three vendor-specific basis sets (GE, Philips, and Siemens) for each algorithm. Levels of total N-acetylaspartate (tNAA), total choline (tCho), myoinositol (mI), and glutamate+glutamine (Glx) were quantified with respect to total creatine (tCr). Group means and CVs of metabolite estimates agreed well for tNAA and tCho across vendors and algorithms, but substantially less so for Glx and mI, with mI systematically estimated lower by Tarquin. The cohort mean coefficient of determination for all pairs of LCM algorithms across all datasets and metabolites was [Formula], indicating generally only moderate agreement of individual metabolite estimates between algorithms. There was a significant correlation between local baseline amplitude and metabolite estimates (cohort mean [Formula]). While mean estimates of major metabolite complexes broadly agree between linear-combination modelling algorithms at group level, correlations between algorithms are only weak-to-moderate, despite standardized pre-processing, a large sample of young, healthy and cooperative subjects, and high spectral quality. These findings raise concerns about the comparability of MRS studies, which typically use one LCM software and much smaller sample sizes. Graphical Abstract O_TBL View this table: org.highwire.dtl.DTLVardef@6775bdorg.highwire.dtl.DTLVardef@62f27borg.highwire.dtl.DTLVardef@1d77ccorg.highwire.dtl.DTLVardef@a4049aorg.highwire.dtl.DTLVardef@2a1feb_HPS_FORMAT_FIGEXP M_TBL C_TBL Three linear-combination algorithms (Osprey, Tarquin and LCMode) were used to quantify the levels of tNAA, tCho, mI, and Glx in 277 short-TE PRESS. Group means and CVs of metabolite estimates agreed well for tNAA and tCho, but substantially less so for Glx and mI with a cohort mean correlation coefficient of [Formula], indicating moderate agreement between algorithms. These findings raise concerns about the comparability of MRS studies, which typically use one LCM software and much smaller sample sizes.

biochemistry↗