bioRxiv Science⌕ Search

Biology subjects

Zaeimbashi, M.

Publications and source records attributed to Zaeimbashi, M..

3 recordsLinked to original sources

Magnetic Temporal Interference for Noninvasive Focal Brain Stimulation

Non-invasive stimulation of deep brain regions has been a major goal for neuroscience and neuromodulation in the past three decades. Transcranial magnetic stimulation (TMS), for instance, cannot target deep regions in the brain without activating the overlying tissues and has a poor spatial resolution. In this manuscript, we propose a new concept that relies on the temporal interference of two high-frequency magnetic fields generated by two electromagnetic solenoids. To illustrate the concept, custom solenoids were fabricated and optimized to generate temporal interfering electric fields for rodent brain stimulation. C-Fos expression was used to track neuronal activation. C-Fos expression was not present in regions impacted by only one high-frequency magnetic field indicating ineffective recruitment of neural activity in non-target regions. In contrast, regions impacted by two fields that interfere to create a low-frequency envelope display a strong increase in c-Fos expression. Therefore, this magnetic temporal interference solenoid-based system provides a framework to perform further stimulation studies that would investigate the advantages it could bring over conventional TMS systems.

bioengineering↗

Magnetic Temporal Interference For Noninvasive, High-resolution, and Localized Deep Brain Stimulation: Concept Validation

Non-invasive deep brain stimulation has been a major challenge in the field of neuroscience and brain stimulation in the past three decades. Current brain stimulation technologies suffer from such hurdles as the inability to do deep brain stimulation, poor spatial resolution, and invasiveness. Transcranial magnetic stimulation (TMS) technique, for instance, cannot target brain regions deeper than [~]2cm and has a poor spatial resolution, impacting a large area of the peripheral region and leading to various side effects. Implantable electrodes, even though effective for deep brain stimulation, are invasive and carry various drawbacks related to the surgery and site infection. In this paper, we propose a new concept that relies on temporal interference of two high- frequency magnetic fields generated by two electromagnetic coils. The neural system does not respond to each of these high-frequency magnetic fields alone because of the intrinsic low-pass filtering properties of the neural membrane. The peripheral areas of the brain are impacted only by the high-frequency magnetic fields that cannot stimulate the nerves, while the deep brain area where the two fields interfere experiences a magnetic field that contains a low-frequency envelope and therefore the nerves can be stimulated. This technique can noninvasively focus a magnetic or electric beam at any depth inside the brain with a high resolution, without impacting the peripheral regions.

bioengineering↗

Ultra-compact Dual-band Smart NEMS Magnetoelectric Antennas for Simultaneous Wireless Energy Harvesting and Magnetic Field Sensing

Ultra-compact wireless implantable medical devices (IMDs) are in great demand for healthcare applications, in particular for neural recording and stimulation. Current implantable technologies based on miniaturized micro-coils suffer from low wireless power transfer efficiency (PTE) and are not always compliant with the specific absorption rate imposed by the Federal Communications Commission, particularly for deep brain implantation where field attenuation and tissue loss are significant. Moreover, current implantable devices are reliant on recordings of voltage or current. This has two major weaknesses: 1) the necessary direct contact between electrode and tissue degrades over time due to electrochemical fouling and tissue reactions, and 2) the necessity for differential recordings across space. Here, we report, for the first time, an ultra-compact dual-band smart nanoelectromechanical systems magnetoelectric (ME) antenna with a size of 250×174 µm2 that can efficiently perform wireless energy harvesting and sense ultra-small magnetic fields such as those arising from neural activities. The proposed smart ME antenna has a wireless PTE 1∼2 orders of magnitude higher than any other reported miniaturized micro-coil, allowing the wireless IMDs to be compliant with the specific absorption rate (SAR) limit and to operate under safe exposure of radio frequency energy. Furthermore, the magnetic sensing capability of the proposed smart ME antenna, with a limit of detection of 300∼500pT at > 200Hz, should allow the IMDs to record neural magnetic fields from the brain without requiring differential recording.Competing Interest StatementThe authors have declared no competing interest.View Full Text

bioengineering↗