bioRxiv Science⌕ Search

Biology subjects

Wright, T.

Publications and source records attributed to Wright, T..

2 recordsLinked to original sources

Male sex hormone and reduced plakoglobin jointly impair atrial conduction and cardiac sodium currents

Androgenic anabolic steroids (AAS) are commonly abused by young men. Male sex associates with earlier manifestation of common and rare cardiac conditions including atrial fibrillation and arrhythmogenic right ventricular cardiomyopathy (ARVC). Clinical data suggest an atrial involvement in ARVC. The disease is caused by desmosomal gene defects such as reduced plakoglobin expression. Analysis of clinical records from 146 ARVC patients identified male preponderance and increased prevalence of atrial arrhythmias in patients with definite ARVC. Definite patients displayed ECG changes suggesting atrial remodelling. To study mechanisms of atrial remodelling due to desmosomal vulnerability and AAS, young adult male mice, heterozygously deficient for plakoglobin (Plako+/-) and wildtype (WT) littermates, were chronically exposed to 5-dihydrotestosterone (DHT) or placebo. DHT increased atrial expression of pro-hypertrophic, fibrotic and inflammatory transcripts. DHT caused atrial conduction slowing, decreased peak sodium current density, reduced action potential amplitude and lowered the peak depolarisation rate in Plako+/- but not WT atria. Super-resolution microscopy revealed a reduction in Nav1.5 clustering in Plako+/- atrial cardiomyocytes following DHT exposure. These data reveal that AAS combined with plakoglobin deficiency cause pathological atrial electrical remodelling in young male hearts. AAS abuse may increase the risk of atrial myopathy in males with desmosomal gene variants.

molecular biology↗

Video-rate remote refocusing through continuous oscillation of a membrane deformable mirror.

This paper presents the use of a deformable mirror (DM) configured to rapidly refocus a microscope employing a high numerical aperture objective lens. An Alpao DM97-15 membrane DM was used to refocus a 40x/0.80 NA water-immersion objective through a defocus range of -50 to 50 m at 26.3 sweeps per second. We achieved imaging with a mean Strehl metric of > 0.6 over a field of view in the sample of 200x200 m2 over a defocus range of 77 m. We describe an optimisation procedure where the mirror is swept continuously in order to avoid known problems of hysteresis associated with the membrane DM employed. This work demonstrates that a DM-based refocusing system could in the future be used in light-sheet fluorescence microscopes to achieve video-rate volumetric imaging.

bioengineering↗