bioRxiv Science⌕ Search

Biology subjects

Wollant, B. C.

Publications and source records attributed to Wollant, B. C..

2 recordsLinked to original sources

Aptamer charge-amplified field-effect transistor biosensors achieve picomolar detection limits for small-molecule biomarkers in complex biological matrices

Aptamers are attractive receptors for small-molecule biomarker detection in complex samples because of their high stability, affinity, and specificity, but aptamer-based sensors generally lack the sensitivity to detect low-abundance analytes. As a solution, we developed the charge-amplified FET (CAFET) aptamer biosensor, which is designed to amplify the net charge variation within the Debye length that occurs as a consequence of aptamer-target binding. Our sensor utilizes a strand-displacement aptamer switch, which releases an initially-hybridized displacement strand (DS) upon target binding and thus induces a measurable net charge variation within the Debye length that is amplified to a large FET current response as signal readout. This signal can be further enhanced by adding a charge label to the DS. As a consequence, our sensor can achieve far greater sensitivity than previously described aptamer-FET sensors, where the binding-induced local charge variation is modest. We demonstrate 3-hydroxykynurenine and progesterone detection with a picomolar limit of detection in undiluted human plasma--four orders of magnitude lower than the dissociation constant (KD) of the aptamer component. The CAFET sensor design is modular and should be adaptable for the detection of a wide range of clinically-informative low-abundance analytes in complex samples.

bioengineering↗

Direct Optical Detection of Factor Xa Activity in Minimally Processed Whole Blood

The ability to measure factor Xa activity directly in whole blood samples offers a path toward point-of-care monitoring and personalized anticoagulant dosage, potentially reducing bleeding risk and other anticoagulant-associated complications. We present a strategy to enable direct optical detection of factor Xa in minimally processed whole blood samples. Our strategy relies on a custom FRET-pair labeled DNA-peptide substrate, allowing FRET ratio to be monitored as an indicator of factor Xa activity. Substrates are tethered to a tapered-fiber sensor to allow evanescent detection of fluorescence directly at the sensor surface, minimizing background media interference and enabling detection directly in blood samples. After characterizing the custom substrate and demonstrating the correlation of fiber-based measurements to an existing chromogenic assay, we demonstrate the detection of endogenous factor Xa activity in >85% whole blood. Finally, we demonstrate the detection of therapeutic concentrations of enoxaparin, a widely used anticoagulant, directly in 90% whole blood in less than an hour and correlate these measurements to activated partial thromboplastin time (aPTT) testing. Together, these results indicate a promising strategy to achieve point-of-care factor Xa detection, enabling personalized anticoagulant treatment and reducing adverse outcomes.

bioengineering↗