bioRxiv Science⌕ Search

Biology subjects

Wiseman, K.

Publications and source records attributed to Wiseman, K..

6 recordsLinked to original sources

Inhibition of cell-mediated immunity in type 1 diabetes by beta cell-targeted PD-1 agonists in pancreas tissue slices

Tissue-targeted immunotherapies for type 1 diabetes (T1D) hold potential to protect pancreatic beta cells while minimizing systemic immunosuppression. We used a bispecific agonist called Immune Modulating Monoclonal-TCR Against Autoimmune Disease (ImmTAAI), consisting of a T cell receptor (TCR) targeting domain fused with a PD-1 agonist to specifically bind beta cells and suppress autoreactive T cells. We used live pancreas slices to demonstrate targeting of ImmTAAI molecules to pre-proinsulin peptide-HLA-A2 complexes on human beta cells. ImmTAAI protected beta cells from T cell killing by increasing T cell motility and inhibiting cytokine secretion. ImmTAAI treatment also increased the motility of islet-infiltrating T cells in slices from a donor with recent-onset T1D and preserved insulin secretion in slices co-cultured with T cell avatars transduced with diabetogenic TCRs. These data demonstrate that ImmTAAI molecules have the potential to limit T cell activity locally, making this an attractive platform to elicit targeted immunoregulation in T1D. One Sentence SummaryWe demonstrate inhibition of cellular immunity in human type 1 diabetes using a beta cell-targeting, affinity-enhanced TCR fused to a PD-1 agonist.

bioengineering↗

A simplified hybrid capture approach retains high specificity and enables PCR-free workflow

Hybrid capture is a critical technology for selective enrichment of genomic regions of interest, enabling cost-effective focused sequencing in both clinical and research applications. We present a simplified hybrid capture approach that eliminates complexities typically associated with hybridization-based selection methods by directly loading the hybridization product onto the sequencing flow cell. The workflow removes bead-based steps, washes, and post-hybridization PCR, while retaining high capture specificity and library complexity. The approach is enabled by the development of a streptavidin flow cell surface, a method to circularize and amplify captured targets on the flow cell, and a fast hybridization protocol. We demonstrate application across targeted panel sizes and improvements to library complexity and variant calling. We also show how the approach can be used to create an entirely PCR-free targeted sequencing workflow that further improves variant calling and enables the detection of repeat expansions.

genomics↗

FLEXIBLE, PRODUCTION-SCALE, HUMAN WHOLE GENOME SEQUENCING ON A BENCHTOP SEQUENCER

Human whole-genome sequencing (hWGS) provides comprehensive genomic information that can potentially help guide research in disease prevention and treatment and ultimately improve human health. Recent advancements in sequencing technology have improved sequencing quality and further reduced sequencing costs on bench-top sized instruments, making whole-genome sequencing an accessible technology for broader use. Here, we demonstrate the feasibility of a large whole genome sequencing project using a benchtop sequencer in a small laboratory setting, on a scale previously reserved for production-scale factory-sized machines. In this project, 807 samples were prepared and sequenced across 313 flow cells, with high sequencing quality at a median %Q30 of 96.6% and a median %Q40 of 89.31%. To screen library quality and maximize sample yield, we utilized 48-plex sample pre-pool QC runs to provide >1x coverage per sample prior to sample pooling and full-depth sequencing. With this strategy, we consistently achieved >30x human whole genome sequencing of three-plex sample trios with standard settings or up to 4 samples per run with a high-throughput run setting. Additionally, this low-pass data provided valuable sample-level insights, allowing for detection of chromosome copy number variations (CNV) prior to full-depth sequencing. With three instruments running concurrently, >2,800 30x human whole genomes could be sequenced per year. To further demonstrate additional flexibility present in the platform, we also explored two different use cases 1) large insert sizes (1kb+) library to achieve superior genome coverage; 2) a proof of concept for rapid WGS sequencing to minimize sample to answer turnaround time for time-critical sequencing applications. Sequencing of a 2x100 >30x human WGS can be achieved in <12 hours and subsequent generation of fastq, bam and vcf in <1 additional hour. This study provides a cost-effective and flexible real-world demonstration of achieving both high quality hWGS sequencing and instrument flexibility without the need for complex batching schemes or factory-sized sequencers.

molecular biology↗

Development and extensive sequencing of a broadly-consented Genome in a Bottle matched tumor-normal pair for somatic benchmarks

The Genome in a Bottle Consortium (GIAB), hosted by the National Institute of Standards and Technology (NIST), is developing new matched tumor-normal samples, the first to be explicitly consented for public dissemination of genomic data and cell lines. Here, we describe a comprehensive genomic dataset from the first individual, HG008, including DNA from an adherent, epithelial-like pancreatic ductal adenocarcinoma (PDAC) tumor cell line and matched normal cells from duodenal and pancreatic tissues. Data for the tumor-normal matched samples comes from seventeen distinct state-of-the-art whole genome measurement technologies, including high depth short and long-read bulk whole genome sequencing (WGS), single cell WGS, and Hi-C, and karyotyping. In future publications, these data will be used by the GIAB Consortium to develop matched tumor-normal benchmarks for somatic variant detection. We expect these data to facilitate innovation for whole genome measurement technologies, de novo assembly of tumor and normal genomes, and bioinformatic tools to identify small and structural somatic mutations. This first-of-its-kind broadly consented open-access resource will facilitate further understanding of sequencing methods used for cancer biology.

genomics↗

Utility Analyses of AVITI Sequencing Chemistry

BackgroundDNA sequencing is a critical tool in modern biology. Over the last two decades, it has been revolutionized by the advent of massively parallel sequencing, leading to significant advances in the genome and transcriptome sequencing of various organisms. Nevertheless, challenges with accuracy, lack of competitive options and prohibitive costs associated with high throughput parallel short-read sequencing persist. ResultsHere, we conduct a comparative analysis using matched DNA and RNA short-reads assays between Element Biosciences AVITI and Illuminas NextSeq 550 chemistries. Similar comparisons were evaluated for synthetic long-read sequencing for RNA and targeted single-cell transcripts between the AVITI and Illuminas NovaSeq 6000. For both DNA and RNA short-read applications, the study found that the AVITI produced significantly higher per sequence quality scores. For PCR-free DNA libraries, we observed an average 89.7% lower experimentally determined error rate when using the AVITI chemistry, compared to the NextSeq 550. For short-read RNA quantification, AVITI platform had an average of 32.5% lower error rate than that for NextSeq 550. With regards to synthetic long-read mRNA and targeted synthetic long read single cell mRNA sequencing, both platforms respective chemistries performed comparably in quantification of genes and isoforms. The AVITI displayed a marginally lower error rate for long reads, with fewer chemistry-specific errors and a higher mutation detection rate. ConclusionThese results point to the potential of the AVITI platform as a competitive candidate in high-throughput short read sequencing analyses when juxtaposed with the Illumina NextSeq 550.

genomics↗

SPRTN Protease and Checkpoint Kinase 1 Cross-Activation Loop Safeguards DNA Replication

The SPRTN metalloprotease is essential for DNA-protein crosslink (DPC) repair and DNA replication in vertebrate cells. Cells deficient in SPRTN protease activity exhibit severe DPC-induced replication stress and genome instability, manifesting as premature ageing and liver cancer in humans and mice. Strikingly, SPRTN-deficient cells also show a severe G2/M checkpoint defect and fail to activate a robust checkpoint kinase 1 (CHK1) signalling cascade normally triggered in response to replication stress. Here, we show that SPRTN activates the CHK1 signalling cascade during physiological (steady-state) DNA replication by proteolysis-dependent eviction of CHK1 from chromatin. The N-terminal CHK1 fragments cleaved by SPRTN protease still possess kinase activity and phosphorylate SPRTN. This CHK1-dependent phosphorylation stimulates SPRTN recruitment to chromatin to further promote CHK1 eviction from chromatin, DPC removal and unperturbed DNA replication. Our data suggest that a SPRTN-CHK1 cross-activation loop is essential for steady-state DNA replication and protection from DNA replication stress, a major source of genome instability in diseases that cause premature ageing and cancer. In addition, we disclose a mechanism of CHK1 activation during physiological DNA replication, when long stretches of single stranded (ss) DNA that are induced by genotoxic stress and activate canonical and robust CHK1 signalling are not present.

cell biology↗