bioRxiv Science⌕ Search

Biology subjects

Wiedemeyer, M.

Publications and source records attributed to Wiedemeyer, M..

2 recordsLinked to original sources

High Resolution Multi-Pass Astral Analyzer Quantification Enables Highly Multiplexed 35-Plex Tandem Mass Tag Proteomics

Tandem mass tags (TMT) allow highly multiplexed and thus high-throughput, precisely quantitative proteomic analysis. Incorporation of additional deuterated reporter channels has near-doubled the multiplexation achieved with Thermo Scientific TMTpro reagents from 18 to 35-plex but requires extremely high [~]100k analyzer resolving power at m/z 128 to differentiate and quantify reporter ion channels, far beyond any single reflection time-of-flight analyzer, and exceeding the multi-reflection Thermo Scientific Astral analyzer in its standard operation. A multi-pass mode of Astral operation has been developed for the Thermo Scientific Orbitrap Astral Zoom mass spectrometer that triples the ion path to 90 m, more than doubling resolving power for a narrow m/z range. This "TMT HR mode" has been integrated into a new method of TMT proteomic analysis that splits regular MS2 analysis of labeled peptides into paired measurements comprising wide mass range scans for peptide identification, and TMT HR mode scans for reporter ion quantification. The method has been shown to accurately quantify 32-plex labeled HeLa protein lysate and provide far greater depth of analysis as state-of-the-art Orbitrap-only methods, while analysis of 11-plex labeled yeast showed no analytical depth sacrificed vs regular Orbitrap Astral TMT analysis. Further comparative measurements of a 2-cell line 35-plex sample demonstrated greater analytical depth, and similar quantitative precision, to "gold standard" Orbitrap MS3 methods.

biochemistry↗

Parallelized Acquisition of Orbitrap and Astral Analyzers Enables High-Throughput Quantitative Analysis.

The growing trend towards high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time, and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass resolving quadrupole, the Orbitrap and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared to state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with high dynamic range and resolution, synchronized with Astral analyzers acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=100 SRC="FIGDIR/small/543408v1_ufig1.gif" ALT="Figure 1"> View larger version (35K): org.highwire.dtl.DTLVardef@1eedfdeorg.highwire.dtl.DTLVardef@1ab7939org.highwire.dtl.DTLVardef@a3b2f8org.highwire.dtl.DTLVardef@13ac46b_HPS_FORMAT_FIGEXP M_FIG C_FIG

cell biology↗