Real-time, automated, standardized, and transparent analysis of microfluidic nanoparticle data with RPSPASS

Extracellular vesicles (EVs) are lipid spheres released from cells. Research utilizing EVs has met several hurdles owing to the small size of the majority of EVs and other nanoparticles (<150 nm) and the lack of detection technologies capable of providing high-throughput single particle measurements at this scale. The use of high-throughput single particle measurements is critical for the assessment of EV heterogeneity and abundance which are features often used to assess the development of isolation protocols or particle characterization. The Coulter principle, known in the field as resistive pulse sensing (RPS), has been used for several decades to size and count cells. More recently, this technology has evolved to accommodate nanoparticle analysis. In the last decade a platform utilizing microfluidic resistive pulse sensing (MRPS) has been demonstrated for nanoparticles, offering ergonomic characterization of nanoparticles along with utilizing open format data. To date, assessment of MRPS accuracy and reporting standards have not been assessed. With the aim of increasing data accuracy, ergonomics, and reporting transparency, we developed a microfluidic resistive pulse sensing post-acquisition analysis software (RPSPASS) application for automated cohort calibration, population gating, statistical output, QC plot generation, alternative data file outputs, and standardized reporting templates.

bioengineering↗

A simple, high-throughput method of protein and label removal from extracellular vesicle samples

Evidence continues to increase of the clinical utility extracellular vesicles (EVs) can provide as translational biomarkers. While a wide variety of EV isolation and purification methods have been implemented, few techniques are high-throughput and scalable for removing excess fluorescent reagents (e.g. dyes, antibodies). EVs are too small to be recovered from routine cell-processing procedures, such as filtration or centrifugation. The lack of suitable methods for removing unbound labels, especially in optical assays, is a major roadblock to accurate EV phenotyping and utilization of EV assays in a translational or clinical setting. Therefore, we developed a method for using a multi-modal resin, referred to as EV-Clean, to remove unbound labels from EV samples, and we demonstrate improvement in flow cytometric EV analysis with the use of this EV-Clean method.

biochemistry↗

Light scatter and fluorescence calibration allow standard comparisons of small particle data between different instruments.

Flow cytometers have been utilized for the analysis of submicron-sized particles since the late 1970s. Initially, virus analyses preceded extracellular vesicle (EV), which began in the 1990s. Despite decades of documented use, the lack of standardization in data reporting has resulted in a growing body of literature that cannot be easily interpreted, validated, or reproduced. This has made it difficult for objective assessments of both assays and instruments, in-turn leading to significant hindrances in scientific progress, specifically in the study of EVs, where the phenotypic analysis of these submicron-sized vesicles is becoming common-place in every biomedical field. Methods for fluorescence and light scatter standardization are well established and the reagents to perform these analyses are commercially available. However, fluorescence and light scatter calibration are not widely adopted by the small particle community as methods to standardize flow cytometry data. In this proof-of-concept study carried out as a resource for use at the CYTO2019 workshop, we demonstrate for the first-time simultaneous fluorescence and light scatter calibration of small particle data to show the ease and feasibility of this method for standardized flow cytometry data reporting. This data was acquired using standard configuration commercial flow cytometers, with commercially available materials, published methods, and freely available software tools. We show that application of light scatter, fluorescence, and concentration calibration can result in highly concordant data between flow cytometry platforms independent of instrument collection angle, gain/voltage settings, and flow rate; thus, providing a means of cross-comparison in standard units.

cell biology↗