A method for efficient, rapid, and minimally invasive implantation of individual non-functional motes with penetrating subcellular-diameter carbon fiber electrodes into rat cortex

ObjectiveDistributed arrays of wireless neural interfacing chips with 1-2 channels each, known as "neural dust", could enhance brain machine interfaces (BMIs) by removing the wired connection through the scalp and increasing biocompatibility with their submillimeter size. Although several approaches for neural dust have emerged, a procedure for implanting them in batches that builds upon the safety and performance of currently used electrodes remains to be demonstrated. ApproachHere, we demonstrate the feasibility of implanting batches of wireless motes that rest on the cortical surface with carbon fiber electrodes of subcellular diameter (6.8-8.4 {micro}m) that penetrate to a target brain depth of 1 mm without insertion aids. To simulate their implantation, we assembled more than 230 mechanically equivalent motes and affixed them to insertion tools with polyethylene glycol (PEG), a quickly dissolvable and biocompatible material. Then, we implanted mote grids of multiple configurations into rat cortex in vivo and evaluated insertion success and their arrangement on the brain surface using photos and videos captured during their implantation. Main ResultsWhen placing motes onto the insertion device, we found that they aggregated in molten PEG such that the array pitch was only 5% wider than the dimensions of the mote bases themselves (240 x 240 {micro}m). Overall, we found that motes with this arrangement could be inserted into rat cortex with a high success rate, as 171/186 (92%) motes in 4x4 (N=4) and 5x5 (N=5) square grid configurations were successfully inserted using the insertion device alone. After implantation, measurements of how much motes tilted (22{+/-}9{degrees}, [X]{+/-}S) and had been displaced relative to their original positions were smaller than those measured for devices implanted inside the brain in the literature. SignificanceCollectively, these data establish the viability of safely implementing motes with ultrasmall electrodes and epicortically-situated chips for use in future BMIs.

bioengineering↗

Profiling neurons surrounding subcellular-scale carbon fiber electrode tracts enables modeling recorded signals

Characterizing the relationship between neuron spiking and the signals electrodes record is vital to defining the neural circuits driving brain function and informing computational modeling. However, electrode biocompatibility and precisely localizing neurons around the electrodes are critical to defining this relationship. Here, we show the ability to localize post-explant recording tips of subcellular-scale carbon fiber electrodes and surrounding neurons. Immunostaining of astrocyte, microglia, and neuron markers confirmed improved tissue health. While neurons near implants were stretched, their number and distribution were similar to control, suggesting that these minimally invasive electrodes demonstrate the potential to sample naturalistic neural populations. This motivated prediction of the spikes produced by neurons nearest to the electrodes using a model fit with recorded electrophysiology. These simulations show the first direct evidence that neuron placement in the immediate vicinity of the recording site influences how many spike clusters can be reliably identified by spike sorting.

neuroscience↗

Carbon Fiber Electrodes for Intracellular Recording and Stimulation

To understand neural circuit dynamics, it is critical to manipulate and record from many neurons, ideally at the single neuron level. Traditional recording methods, such as glass microelectrodes, can only control a small number of neurons. More recently, devices with high electrode density have been developed, but few of them can be used for intracellular recording or stimulation in intact nervous systems, rather than on neuronal cultures. Carbon fiber electrodes (CFEs) are 8 micron-diameter electrodes that can be organized into arrays with pitches as low as 80 {micro}m. They have been shown to have good signal-to-noise ratios (SNRs) and are capable of stable extracellular recording during both acute and chronic implantation in vivo in neural tissue such as rat motor cortex. Given the small fiber size, it is possible that they could be used in arrays for intracellular stimulation. We tested this using the large identified and electrically compact neurons of the marine mollusk Aplysia californica. The cell bodies of neurons in Aplysia range in size from 30 to over 250 {micro}m. We compared the efficacy of CFEs to glass microelectrodes by impaling the same neurons cell body with both electrodes and connecting them to a DC coupled amplifier. We observed that intracellular waveforms were essentially identical, but the amplitude and SNR in the CFE were lower than in the glass microelectrode. CFE arrays could record from 3 to 8 neurons simultaneously for many hours, and many of these recordings were intracellular as shown by recording from the same neuron using a glass microelectrode. Stimulating through CFEs coated with platinum-iridium had stable impedances over many hours. CFEs not within neurons could record local extracellular activity. Despite the lower SNR, the CFEs could record synaptic potentials. Thus, the stability for multi-channel recording and the ability to stimulate and record intracellularly make CFEs a powerful new technology for studying neural circuit dynamics.

neuroscience↗

Auditory-Visual Interactions in the Blind with Artificial Vision: Are Multisensory Perceptions Restored After Decades of Blindness?

In the sighted, auditory and visual perception typically interact strongly and influence each other significantly. Blindness acquired in adulthood alters these multisensory pathways. During blindness, it has been shown that the senses functionally reorganize, enabling visual cortex to be recruited for auditory processing. It is yet unknown whether this reorganization is permanent, or whether auditory-visual interactions can be re-established in cases of partial visual recovery.\n\nRetinal prostheses restore visual perception to the late blind and provide an opportunity to determine if these auditory-visual connections and interactions are still viable after years of plasticity and neglect. We tested Argus II retinal prosthesis patients (N = 7) for an auditory-visual illusion, the ventriloquist effect, in which the perceived location of an auditory stimulus is modified by the presence of a visual stimulus. Prosthetically-restored visual perception significantly modified patients auditory perceptions, comparable to results with sighted control participants (N = 10). Furthermore, the auditory-visual interaction strength in retinal prosthesis patients exhibited a significant partial anti-correlation with patient age, as well as a significant partial correlation with duration of prosthesis use.\n\nThese results indicate that auditory-visual interactions can be restored after decades of blindness, and that auditory-visual processing pathways and regions can be re-engaged. Furthermore, they indicate the resilience of multimodal interactions to plasticity during blindness, and that this plasticity can either be partially reversed or at least does not prevent auditory-visual interactions. Finally, this study provides hope for the restoration of sensory perception, complete with multisensory integration, even after years of visual deprivation.\n\nSignificanceRetinal prostheses restore visual perception to the blind by means of an implanted retinal stimulator wirelessly connected to a camera mounted on glasses. Individuals with prosthetic vision can locate and identify simple objects, and identify the direction of visual motion. A key question is whether this prosthetic vision will interact with the other senses, such as audition, in the same way that natural vision does. We found that artificial vision, like natural vision, can alter auditory localization. This suggests that the brain processes prosthetic vision similarly to natural vision despite altered visual processing in the retina. In addition, it implies that reorganization of the senses during blindness may be reversible, allowing for the rehabilitation of crossmodal interactions after visual restoration.

neuroscience↗

A model of ganglion axon pathways accounts for percepts elicited by retinal implants

Retinal prostheses, now implanted in over 250 patients worldwide, electrically stimulate surviving cells in order to evoke neuronal responses that are interpreted by the brain as visual percepts ( phosphenes). However, instead of seeing focal spots of light, current implant users perceive highly distorted phosphenes that vary in shape both across subjects and electrodes. We characterized these distortions by asking users of the Argus retinal prosthesis system (Second Sight Medical Products) to draw elicited percepts on a touchscreen. We found that phosphene shape could be accurately predicted by simulating the topographic organization of nerve fiber bundles in each subjects retina. Our model shows that activation of ganglion axons contributes to a rich repertoire of phosphene shapes, successfully replicating percepts ranging from blobs to oriented streaks and wedges depending on electrode location. This work provides a first step towards future devices that incorporate stimulation strategies tailored to each individual patients retinal neurophysiology.\n\nOne Sentence SummaryWe show that the perceptual experience of retinal implant users can be accurately predicted using a computational model that simulates the topographic organization of each individual patients retinal ganglion axon pathways.

neuroscience↗