bioRxiv ScienceSearch

Biology subjects

Wang, Y.-X.

Publications and source records attributed to Wang, Y.-X..

8 recordsLinked to original sources

Comparison of tri-exponential decay vs. bi-exponential decay and full fitting vs. segmented fitting for modeling liver intravoxel incoherent motion diffusion MRI

PurposeTo determine whether bi- or tri-exponential models, and full or segmented fittings, better fit IVIM imaging signal of healthy livers.\n\nMaterials and methodsDiffusion-weighted images were acquired with a 3-T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0[~]800 s/mm2). Eighteen healthy volunteers had liver scanned twice in the same session, and then once again in another session. Region of interest (ROI)-based measurements were processed with bi-exponential model full fitting and segmented fitting (threshold b-value = 80 s/mm2), as well as tri-exponential model full fitting and segmented fitting (threshold b-value = 200 s/mm2).\n\nResultsWith all scans signal averaged, bi-exponential model full fitting showed Dslow=1.14, Dfast=193.6x10-3 mm2/s, and PF=16.9%, and segmented fitting showed Dslow=1.03, Dfast=56.7x10-3 mm2/s, and PF=21.3%. IVIM parameters derived from tri-exponential model were similar for full fitting and segmented fitting, with a slow (Dslow=0.98x10-3 mm2/s; Fslow=76.4 or 76.6%), a fast (Dfast=15.1 or 15.4x10-3 mm2/s; Ffast=11.8 or 11.7%) and a very fast (DVfast=445.0 or 448.8x10-3 mm2/s; FVfast=11.8 or 11.7 %) diffusion compartments. Tri-exponential model provided an overall better fit than bi-exponential model. For bi-exponential model, full fitting provided better fit at very low and low b-values compared with segmented fitting with the later tended to underestimate Dfast, however, segmented method demonstrated lower error in signal prediction for high b-values. Compared with full fitting, tri-exponential segmented fitting offered better scan-rescan reproducibility.\n\nConclusionFor healthy liver, tri-exponential modelling is preferred than bi-exponential modelling. For bi-exponential model, segmented fitting underestimates Dfast, but offers more accurate estimation of Dslow.

biophysics

Structural differences between pri-miRNA paralogs promotes alternative Drosha cleavage and expands target repertoires

MicroRNA (miRNA) processing begins with Drosha cleavage, the fidelity of which is critical for downstream processing and mature miRNA target specificity. To understand how pri-miRNA sequence and structure influence Drosha cleavage, we studied the maturation of three pri-miR-9 paralogs, which encode the same mature miRNA but differ in the surrounding scaffold. We show that pri-miR-9-1 has a unique Drosha cleavage profile due to its distorted and flexible stem structure. Cleavage of pri-miR-9-1, but not pri-miR-9-2 or pri-miR-9-3, generates an alternative-miR-9 with a shifted seed sequence that expands the scope of its target RNAs. Analyses of low grade glioma patient samples indicate that the alternative-miR-9 plays a distinct role in preventing tumor progression. To generalize our model, we provide evidence that distortion of pri-miRNA stems correlates with Drosha cleavage at non-canonical sites. Our studies reveal that pri-miRNA paralogs can have distinct functions via differential Drosha processing.

molecular biology

Retinoblastoma 1 (RB1) modulates the proliferation of chicken preadipocytes

Retinoblastoma 1 (RB1) has been extensively studied in mammalian species, but its function in avian species is unclear. The objective of this study was to reveal the role of chicken RB1 (Gallus gallus RB1, gRB1) in the proliferation of preadipocytes. In the current study, quantitative real-time PCR analysis showed that the expression levels of gRB1 transiently increased during the proliferation of preadipocytes. The MTT assay showed that gRB1 overexpression suppressed preadipocyte proliferation, and gRB1 interference promoted preadipocyte proliferation. Additionally, cell-cycle analysis indicated that gRB1 may play a crucial role in the G1/S transition. Consistently, gene expression analysis showed that gRB1 knockdown promoted marker of proliferation Ki-67 (MKi67) expression at 96 h (P < 0.05), and that overexpression of gRB1 reduced MKi67 expression at 72 h (P < 0.05). Together, our study demonstrated that gRB1 inhibited preadipocyte proliferation at least in part by inhibiting the G1 to S phase transition.

genetics

IVIM parameters have good scan-rescan reproducibility when evidential motion contaminated and poorly fitted image data are removed

BackgroundIntravoxel Incoherent Motion (IVIM) diffusion MRI is a promising technique for liver pathology evaluation, but this techniques scan-rescan reproducibility has been reported to be unsatisfactory.\n\nObjectiveTo understand whether IVIM MRI parameters for liver parenchyma can be good after removal of motion contaminated and/or poorly fitted image data.\n\nMaterial and MethodsEighteen healthy volunteers had liver scanned twice at the same session to assess scan-rescan repeatability, and again in another session after an average interval of 13 days to assess reproducibility. Diffusion weighted image were acquired with a 3T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0 to 800 s/mm2). Measurement was performed on the right liver with segmented-unconstrained least square fitting. Image series with evidential anatomical mismatch, apparent artifacts, and poorly fitted signal intensity vs. b-value curve were excluded. A minimum of three slices was deemed necessary for IVIM parameter estimation of a liver.\n\nResultsWith total 54 examinations, 6 scans did not satisfy inclusion criteria, leading to a success rate of 89%; and 14 volunteers were finally included. With each scan a mean of 5.3 slices (range: 3-10 slices) were utilized for analysis. Using threshold b-value=80s/mm2, the coefficient of variation and within-subject coefficient of variation for repeatability and reproducibility were: 2.86% and 4.24% for Dslow, 3.81% and 4.24%, for PF, 18.16% and 24.88% for Dfast; and those for reproducibility were 2.48% and 3.24% for Dslow; 4.91% and 5.38% for PF; 21.18% and 30.89% for Dfast.\n\nConclusionIVIM parameter scan-rescan reproducibility can be potentially good.

biophysics

Liver physiological T1rho dynamics associated with age and gender

PurposeUsing a single breathhold black blood sequence, the current study aims to understand the physiological ranges of liver T1rho relaxation for women and men.\n\nMaterials and MethodsThis volunteer study was conducted with institutional ethics committee approval, and included 62 females (age mean: 38.9 years; range: 18-75 years) and 34 males (age mean: 44.7 years, range: 24-80 years). MRI was conducted with a 3.0 T scanner, with six spin-lock times of 0, 10, 20, 25, 35, 50msec and a single breathhold of 12 seconds. Six slices were acquired for each examination.\n\nResultsFemale liver T1rho value ranged between 35.07 to 51.97ms, showed an age-dependent decrease with younger women had a higher measurement. Male Liver T1rho values ranged between 34.94 to 43.39 ms, and there was no evidential age-dependence. For females, there was a trend that liver T1rho value could be 4%-5% lower during menstrual phase than nonmenstrual phase. For both females and males, no evidential association was seen between body mass index and liver T1rho.\n\nConclusionLiver T1rho physiological value for males have relatively narrow distribution, while physiological value for females have wider distribution, and decreases with age.\n\nKey points1. Liver T1rho shows an age-dependency in women, with young women showing higher measurement. This age-dependency of liver T1rho measurement is not evidential in men. Post-menopausal women have similar liver T1rho value as men.\n\n2. Women at menstrual phase may have slight lower liver T1rho measurement.\n\n3. No association was noted between body mass index and liver T1rho\n\n4. When blood signal suppression sequence is used, in a population of 62 healthy women and 34 healthy men, the highest measured liver T1rho was 52 msec for young women, 44.7 msec for post-menopausal women, and 43.4 msec for men.

biophysics

Dependence of Intravoxel Incoherent Motion MR threshold b-value selection for separating perfusion and diffusion compartment and liver fibrosis diagnostic performance.

PurposeTo explore how the selection of threshold b-value impacts Intravoxel Incoherent Motion (IVIM) diffusion parameters of PF (f), Dslow (D),and Dfast (D*) values and their performance for liver fibrosis detection.\n\nMaterials and MethodsFifteen healthy volunteers and 33 hepatitis-b patients were included. With a 1.5 T MR scanner and respiration gating, IVIM data was acquired with 10 b-values of 10,20,40,60,80,100,150, 200, 400, and 800 s/mm2. Signal measurement was performed on right liver. Segmented-unconstrained analysis was used to compute IVIM parameters, and six threshold b-values between 40 and 200 s/mm2 were compared. PF, Dslow, and Dfast values were placed along the x-axis, y-axis, and z-axis, and a plane was defined to separate volunteers from patients.\n\nResultsHigher threshold b-values were associated with higher PF measurement; while lower threshold b-values led to higher Dslow and Dfast measurements. The dependence of PF, Dslow, and Dfast on threshold b-value differed between healthy livers and fibrotic livers; with the healthy livers showing a higher dependence. Threshold b-value=60 s/mm2 showed the largest mean distance between healthy liver datapoints vs. fibrotic liver datapoints in 3-dimensional space.\n\nConclusionFor segmented-unconstrained analysis, the selection of threshold b-value=60 s/mm2 improves IVIM diffusion differentiation between healthy livers and fibrotic livers.

biophysics

Thoracolumbar Intervertebral Disc Area Morphometry In Elderly Chinese Men And Women: Radiographic Quantifications At Baseline And Changes At Year-4 Follow-Up

The manuscript submitted does not contain information about medical device(s)/drug(s). No benefits in any form have been or will be received from a commercial party related directly or indirectly to the subject of this manuscript.\n\nStudy DesignA population-based radiographic study with longitudinal follow-up.\n\nObjectiveTo develop a quantitative index for lumbar disc space narrowing (DSN) evaluation in elderly subjects; to determine how DSN in the elderly is influenced by osteoporosis and gender.\n\nSummary of Background DataThere is paucity of research on quantitative classification of lumbar DSN based on disc areal morphometry.\n\nMethodsWith the database of Osteoporotic Fractures in Men (Hong Kong) and Osteoporotic Fractures in Women (Hong Kong) Studies and those who attended the year-4 follow-up (n = 1519 for men and n = 1546 for women), data of 491 women and 592 men were randomly selected. The anterior, middle, and posterior heights, anteroposterior diameter and area of intervertebral discs (T4T5 to L4L5) were measured on lateral radiographs. Disc Area Index for Lumbar Spine (DAIL, disc area divided by the mean of the sum of square of the adjacent upper and lower vertebrae mid-height anterior-posterior diameter) was developed and compared with semi-quantitative DSN expert grading.\n\nResultsDAIL correlated with semi-quantitative grading, with sensitivity and specificity varying from 87.3% to 96.8% for grade-1 DSN (<30% reduction in disc height), and 92.9 % to 100% for grade-3 DSN (>60% reduction in disc height). The thoracolumbar disc area loss among men and women during 4-years follow-up period varied between 1.32% and 3.56%, and it was greater for women (mean: 2.44%) than for men (mean: 1.90%, p=0.044). Majority of lumbar DSN progressions during 72 to 76 years old were progression from normal disc space to grade-1DSN. Osteoporosis was associated with greater disc area decrease, both for thoracic and lumbar discs.\n\nConclusionLumbar DSN can be quantified using DAIL. In elderly Chinese, intervertebral disc narrowing over a 4-year period was greater in women than men, and associated with the presence of osteoporosis.

epidemiology

A Combined Use Of Intravoxel Incoherent Motion MRI Parameters Can Differentiate Early Stage Hepatitis-B Fibrotic Livers From Healthy Livers

This study investigated a combined use of IVIM parameters Dslow (D), PF (f) and Dfast (D*) for liver fibrosis evaluation. 16 healthy volunteers (F0) and 33 hepatitis-b patients (stage F1= 15, stage F2-4 = 18) were included. With a 1.5-T MR scanner and respiration-gating, IVIM diffusion weighted imaging was acquired using a single-shot echo-planar imaging sequence with ten b-values of 10, 20, 40, 60, 80, 100, 150, 200, 400, and 800 s/mm2. Signal measurement was performed on right liver parenchyma. With a 3-dimensional tool, Dslow, PF, and Dfast values were placed along the x-axis, y-axis, and z-axis, and a plane was defined to separate healthy volunteers from patients. 3-dimensional tool demonstrated healthy volunteers and all patients with liver fibrosis could be separated. Classification and Regression Tree showed a combination of PF (PF < 12.55%), Dslow (Dslow < 1.152 x10-3 mm2/s) and Dfast (Dfast <13.36 x10-3 mm2/s) could differentiate healthy subjects and all fibrotic livers (F1-F4) with an area under the curve of logistic regression (AUC) of 0.986. The AUC for differentiation of healthy livers vs. F2-4 livers was 1. PF offered the best diagnostic value, followed by Dslow; however, all three parameters of PF, Dslow, and Dfast contributed to liver fibrosis detection.

biophysics