bioRxiv Science⌕ Search

Biology subjects

Walsh, C. L.

Publications and source records attributed to Walsh, C. L..

5 recordsLinked to original sources

Multidimensional Analysis of the Adult Human Heart in Health and Disease using Hierarchical Phase-Contrast Tomography (HiP-CT)

Cardiovascular diseases (CVDs) are a leading cause of death worldwide. Current clinical imaging modalities provide resolution adequate for diagnosis but are unable to provide detail of structural changes in the heart, across length-scales, necessary for understanding underlying pathophysiology of disease. Hierarchical Phase-Contrast Tomography (HiP-CT), using new (4th) generation synchrotron sources, potentially overcomes this limitation, allowing micron resolution imaging of intact adult organs with unprecedented detail. In this proof of principle study (n=2), we show the utility of HiP-CT to image whole adult human hearts ex-vivo: one control without known cardiac disease and one with multiple known cardiopulmonary pathologies. The resulting multiscale imaging was able to demonstrate exemplars of anatomy in each cardiac segment along with novel findings in the cardiac conduction system, from gross (20 um/voxel) to cellular scale (2.2 um/voxel), non-destructively, thereby bridging the gap between macroscopic and microscopic investigations. We propose that the technique represents a significant step in virtual autopsy methods for studying structural heart disease, facilitating research into abnormalities across scales and age-groups. It opens up possibilities for understanding and treating disease; and provides a cardiac blueprint with potential for in-silico simulation, device design, virtual surgical training, and bioengineered heart in the future.

pathology↗

Micro to macro scale analysis of the intact human renal arterial tree with Synchrotron Tomography

The architecture of the kidney vasculature is essential for its function. Although structural profiling of the intact rodent kidney vasculature has been performed, it is challenging to map vascular architecture of larger human organs. We hypothesised that hierarchical phase-contrast tomography (HiP-CT) would enable quantitative analysis of the entire human kidney vasculature. Combining label-free HiP-CT imaging of an intact kidney from a 63-year-old male with topology network analysis, we quantitated vasculature architecture in the human kidney down to the scale of arterioles. Although human and rat kidney vascular topologies are comparable, vascular radius decreases at a significantly faster rate in humans as vessels branch from artery towards the cortex. At branching points of large vessels, radii are theoretically optimised to minimise flow resistance, an observation not found for smaller arterioles. Structural differences in the vasculature were found in different spatial zones of the kidney reflecting their unique functional roles. Overall, this represents the first time the entire arterial vasculature of a human kidney has been mapped providing essential inputs for computational models of kidney vascular flow and synthetic vascular architectures, with implications for understanding how the structure of individual blood vessels collectively scales to facilitate organ function.

bioengineering↗

A closer look at high-energy X-ray-induced bubble formation during soft tissue imaging

Improving the scalability of tissue imaging throughput with bright, coherent X-rays requires identifying and mitigating artifacts resulting from the interactions between X-rays and matter. At synchrotron sources, long-term imaging of soft tissues in solution can result in gas bubble formation or cavitation, which dramatically compromises image quality and integrity of the samples. By combining in-line phase-contrast cineradiography with operando gas chromatography, we were able to track the onset and evolution of high-energy X-ray-induced gas bubbles in ethanol-embedded soft tissue samples for tens of minutes (2 to 3 times the typical scan times). We demonstrate quantitatively that vacuum degassing of the sample during preparation can significantly delay bubble formation, offering up to a twofold improvement in dose tolerance, depending on the tissue type. However, once nucleated, bubble growth is faster in degassed than undegassed samples, indicating their distinct metastable states at bubble onset. Gas chromatography analysis shows increased solvent vaporization concurrent with bubble formation, yet the quantities of dissolved gases remain unchanged. Coupling features extracted from the radiographs with computational analysis of bubble characteristics, we uncover dose-controlled kinetics and nucleation site-specific growth. These hallmark signatures provide quantitative constraints on the driving mechanisms of bubble formation and growth. Overall, the observations highlight bubble formation as a critical, yet often overlooked hurdle in upscaling X-ray imaging for biological tissues and soft materials and we offer an empirical foundation for their understanding and imaging protocol optimization. More importantly, our approaches establish a top-down scheme to decipher the complex, multiscale radiation-matter interactions in these applications. Significance statementBetter probing the X-ray radiation dose limit of bubble formation in biological tissue and developing mitigation methods is essential for improving imaging techniques involving X-ray, such as synchrotron X-ray tomography or crystallography. Here, we combined operando gas chromatography with in-line X-ray phase-contrast radiography on human lung and brain tissue to investigate bubble formation under high-energy X-ray irradiation. We demonstrate that vacuum degassing delays bubble nucleation up to a factor two, depending on the tissue type. Gas chromatography analysis showed increased solvent vaporization during bubble formation; however, the quantities of dissolved gases remained unchanged. Moreover, depending on the nucleation site, bubble growth can be geometrically constrained by sample microstructure, which influence its dynamics.

biochemistry↗

Preparation of large biological samples for high-resolution, hierarchical, multi-modal imaging

Imaging the different scales of biological tissue is essential for understanding healthy organ behavior and pathophysiological changes. X-ray micro-tomography using both laboratory ({micro}CT) and synchrotron sources (sCT) is a promising tool to image the 3D morphology at the macro- and micro-scale of large samples, including intact human organs. Preparation of large samples for high resolution imaging techniques remains a challenge due to limitations with current methods, such as sample shrinkage, insufficient contrast, movement of the sample and bubble formation during mounting or scanning. Here, we describe a protocol to prepare, stabilize, and image large soft-tissue samples with X-ray microtomography. We demonstrate the protocol using intact human organs and Hierarchical Phase-Contrast Tomography (HiP-CT) imaging at the European Synchrotron Radiation Facility, but the protocol is equally applicable to a range of biological samples, including complete organisms, for both laboratory and synchrotron source tomography. Our protocol enhances the contrast of the sample, while preventing sample motion during the scan, even in case of different sample orientations. Bubbles trapped during mounting and those formed during scanning (in case of synchrotron X-ray imaging) are mitigated by multiple degassing steps. The sample preparation is also compatible with magnetic resonance imaging (MRI), CT, and histological observation. We describe a protocol for sample preparation and mounting which requires 25 to 34 days for a large organ such as an intact human brain or heart. This preparation time varies depending on the composition, size, and fragility of the tissue. Use of the protocol enables scanning of intact organs with a diameter of 150 mm with a local pixel size of one micron using HiP-CT.

physiology↗

A multiscale X-ray phase-contrast tomography dataset of whole human left lung

Technological advancements in X-ray imaging using bright and coherent synchrotron sources now allows to decouple sample size and resolution, while maintaining high sensitivity to the microstructure of soft, partially dehydrated tissues. The recently developed imaging technique, hierarchical phase-contrast tomography, is a comprehensive approach to address the challenge of organ-scale (up to tens of centimeters) soft tissue imaging with resolution and sensitivity down to the cellular level. Using this technique, we imaged ex vivo an entire human left lung at an isotropic voxel size of 25.08 m along with local zooms down to 6.05 - 6.5 m and 2.45 - 2.5 m in voxel size. The high tissue contrast offered by the fourth-generation synchrotron source at the European Synchrotron Radiation Facility reveals complex multiscale anatomical constitution of the human lung from the macroscopic (centimeter) down to the microscopic (micrometer) scale. The dataset provides complete organ-scale 3D information of the secondary pulmonary lobules and delineates the microstructure of lung nodules with unprecedented detail.

physiology↗