bioRxiv Science⌕ Search

Biology subjects

Wakatsuki, T.

Publications and source records attributed to Wakatsuki, T..

5 recordsLinked to original sources

Anticipated Loss of Action Consequences Disrupts Motor Execution in Skilled Basketball Shooting

Internal forward models predict the sensory consequences of motor commands; however, whether the anticipated availability of post-action feedback contributes to the precision of the action itself remains unknown. We manipulated the predictability of post-release visual occlusion in skilled basketball players. Participants performed three-point shots while wearing liquid-crystal shutter goggles. The study tested three conditions: a no-occlusion baseline, certain-occlusion condition in which players knew that their vision would be occluded at ball release in every trial, and random-occlusion condition in which they could not predict whether an occlusion would occur. Shooting accuracy declined in the certain-occlusion condition relative to the no-occlusion condition (49.2% vs 41.7%). The random-occlusion condition did not differ from the baseline (46.1%). Within the random condition, the accuracy in occluded trials were virtually identical to that in non-occluded trials (46.6% vs 46.2%), even though the immediate visual occlusion was the same as in the certain-occlusion condition. These results demonstrate that it is not the absence of post-action information per se that disrupts motor execution, but the prior certainty that action consequences will be unavailable. We interpret this finding as a prospective influence of anticipated consequence loss, whereby motor execution depends on whether the prediction-outcome loop remains closable.

animal behavior and cognition↗

Tension-Induced Stiffening of Cytoskeletal Components Regulates Cardiomyocyte Contractility

Cardiomyocytes continuously experience mechanical stimuli that regulate their contractile behavior and contribute to overall heart function. Despite the importance of mechanotransduction in cardiac physiology, the mechanisms by which cardiomyocytes integrate external mechanical cues, such as stretch and environmental stiffness, remain poorly understood. In this study, we present a combined theoretical and experimental framework to investigate how strain-induced cytoskeletal stiffening modulates cardiomyocyte contractility and force generation. Our study elucidates that regulating the mechanical tension cardiomyocytes experience in tissue--whether by modulating environmental stiffness, external stretching, or cardiac fibroblast activation--can effectively tune their contractility, with cytoskeletal strain stiffening playing a central role in this mechanotransductive response.

biophysics↗

Creating cell-specific computational models of stem cell-derived cardiomyocytes using optical experiments

Human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) have gained traction as a powerful model in cardiac disease and therapeutics research, since iPSCs are self-renewing and can be derived from healthy and diseased patients without invasive surgery. However, current iPSC-CM differentiation methods produce cardiomyocytes with immature, fetal-like electrophysiological phenotypes, and the variety of maturation protocols in the literature results in phenotypic differences between labs. Heterogeneity of iPSC donor genetic backgrounds contributes to additional phenotypic variability. Several mathematical models of iPSC-CM electrophysiology have been developed to help understand the ionic underpinnings of, and to simulate, various cell responses, but these models individually do not capture the phenotypic variability observed in iPSC-CMs. Here, we tackle these limitations by developing a computational pipeline to calibrate cell preparation-specific iPSC-CM electrophysiological parameters. We used the genetic algorithm (GA), a heuristic parameter calibration method, to tune ion channel parameters in a mathematical model of iPSC-CM physiology. To systematically optimize an experimental protocol that generates sufficient data for parameter calibration, we created simulated datasets by applying various protocols to a population of in silico cells with known conductance variations, and we fitted to those datasets. We found that calibrating models to voltage and calcium transient data under 3 varied experimental conditions, including electrical pacing combined with ion channel blockade and changing buffer ion concentrations, improved model parameter estimates and model predictions of unseen channel block responses. This observation held regardless of whether the fitted data were normalized, suggesting that normalized fluorescence recordings, which are more accessible and higher throughput than patch clamp recordings, could sufficiently inform conductance parameters. Therefore, this computational pipeline can be applied to different iPSC-CM preparations to determine cell line-specific ion channel properties and understand the mechanisms behind variability in perturbation responses. Author SummaryMany drug treatments or environmental factors can trigger cardiac arrhythmias, which are dangerous and often unpredictable. Human cardiomyocytes derived from donor stem cells have proven to be a promising model for studying these events, but variability in donor genetic background and cell maturation methods, as well as overall immaturity of stem cell-derived cardiomyocytes relative to the adult heart, have hindered reproducibility and reliability of these studies. Mathematical models of these cells can aid in understanding the underlying electrophysiological contributors to this variability, but determining these models parameters for multiple cell preparations is challenging. In this study, we tackle these limitations by developing a computational method to simultaneously estimate multiple model parameters using data from imaging-based experiments, which can be easily scaled to rapidly characterize multiple cell lines. This method can generate many personalized models of individual cell preparations, improving drug response predictions and revealing specific differences in electrophysiological properties that contribute to variability in cardiac maturity and arrhythmia susceptibility. GLOSSARYO_LIModel/parameter calibration: tuning one or more parameters in the computational model so that the model output more closely matches experimental data C_LIO_LIExperiment/protocol optimization: the process of determining what type and amount of data is sufficient but also feasible for our model calibration goals O_LIProtocol conditions - buffer calcium, potassium, or sodium concentrations; addition or removal of stimulus; pacing rates; channel block; etc. C_LIO_LIProtocol length(?) - number of protocol conditions C_LIO_LIProtocol data type(?) -AP, CaT, or both; normalized or non-normalized data C_LIO_LIModel prediction: using the calibrated computational model to simulate response to new (unseen) conditions, drugs, or perturbations (in our case, IKr block) C_LIO_LIPapers on independent validation/prediction C_LI C_LI Computational pipeline: the full process of iPSC-CM computational model calibration; Includes iPSC-CM data acquisition/simulation -> data processing -> parameter calibration using genetic algorithm -> validation of calibrated models on an unseen condition (i.e. evaluating model predictions)

pharmacology and toxicology↗

Bayesian Approach Enabled Objective Comparison of Multiple Human iPSC-derived Cardiomyocytes' Proarrhythmia Sensitivities.

The one-size-fits-all approach has been the mainstream in medicine, and the well-defined standards support the development of safe and effective therapies for many years. Advancing technologies, however, enabled precision medicine to treat a targeted patient population (e.g., HER2+ cancer). In safety pharmacology, computational population modeling has been successfully applied in virtual clinical trials to predict drug-induced proarrhythmia risks against a wide range of pseudo cohorts. In the meantime, population modeling in safety pharmacology experiments has been challenging. Here, we used five commercially available human iPSC-derived cardiomyocytes growing in 384-well plates and analyzed the effects of ten potential proarrhythmic compounds with four concentrations on their calcium transients (CaTs). All the cell lines exhibited an expected elongation or shortening of calcium transient duration with various degrees. Depending on compounds inhibiting several ion channels, such as hERG, peak and late sodium and L-type calcium or IKs channels, some of the cell lines exhibited irregular, discontinuous beating that was not predicted by computational simulations. To analyze the shapes of CaTs and irregularities of beat patterns comprehensively, we defined six parameters to characterize compound-induced CaT waveform changes, successfully visualizing the similarities and differences in compound-induced proarrhythmic sensitivities of different cell lines. We applied Bayesian statistics to predict sample populations based on experimental data to overcome the limited number of experimental replicates in high-throughput assays. This process facilitated the principal component analysis to classify compound-induced sensitivities of cell lines objectively. Finally, the association of sensitivities in compound-induced changes between phenotypic parameters and ion channel inhibitions measured using patch clamp recording was analyzed. Successful ranking of compound-induced sensitivity of cell lines was validated by visual inspection of raw data. Author SummaryCardiac safety is one of the most stringent regulatory risk monitoring during drug development. Regulatory agencies, including the Food and Drug Administration (FDA), require drug developers to conduct thorough preclinical and clinical studies to evaluate drug-induced proarrhythmia risks. The CiPA (Comprehensive in vitro Proarrhythmia Assay) initiative led by the FDA validated the applications of human cardiomyocytes derived from induced pluripotent stem cells in proarrhythmia risk assessments. The assay can be cost effective, and use of high-throughput approaches enables scale-up analysis. However, limited diversity in cell lines to recapitulate heterogeneity of human patients are still lacking in the cardiac safety analysis. We applied various computational tools to maximize capacity for analyzing diverse response of commercially available five cell lines against reference chemical compounds. Limited number of experimental data made it difficult to predict similarities and differences in drug responses among different cell lines. By applying Bayesian approach, our analysis could intuitively grasp the probabilities of expecting different responses from different cell lines.

pharmacology and toxicology↗

Computational Model for Simulating Drug-Induced Arrhythmia Sensitivity of Human iPSC-derived Cardiomyocytes

A mathematical model describing the electrophysiology and ion handling of cardiomyocytes is a complement to experimental analysis predicting drug-induced proarrhythmic potential in humans as proposed by Comprehensive in vitro Proarrhythmia Assay (CiPA). While CiPA endorses the use of the OHara Rudy (ORd) model, which was developed to simulate electrophysiology of human adult ventricular cardiomyocytes (hAVCMs), to predict drug-induced proarrhythmias; the human induced pluripotent stem cell derived-cardiomyocytes (hiPSC-CMs) was proposed for experimental verifications. The hiPSC-CMs, especially cultured in 2D culture dishes, are inherently different from hAVCMs exhibiting different ion channel density and an immature sarcoplasmic reticulum function. To reconcile this mismatch, we have developed a mathematical electrophysiology model of an hiPSC-CM by incorporating differences in gene expressions of ion channels, pumps and receptors in hiPSC-CMs against those found in hAVCMs. This model can be used to model any hiPSC-CM cell line where expression data has been obtained and replaces the background currents for K+ and Na+ in the ORd model with the known ultra-rapid K+ channel and hyperpolarization activated K+/Na+ channel currents. With this new model, three batches each from two different hiPSC-CM cell lines are compared to experimental data of action potential duration. This mathematical model recapitulates a ventricular-like action potential morphology with a Phase 2 plateau lasting a few hundred milliseconds. However, the resting membrane potential is not as depolarized (-65 to -70 mV) as that of hAVCM (-80 mV). The elevated resting membrane potential matches experimental data previously and is thought to keep rapid sodium channels from triggering membrane depolarization instead being replaced by an overexpression of L-Type Ca2+ channel current. This model is a key step in identifying the variability between different hiPSC-CM lines and even batches of the same line, opening the door to realizing analysis of patient specific preparations in the future.

physiology↗