bioRxiv Science⌕ Search

Biology subjects

Varner, H. M.

Publications and source records attributed to Varner, H. M..

2 recordsLinked to original sources

Evolving properties of biological materials captured via needle-based cavity expansion method

BackgroundThe mechanical properties of biological tissues change over time and with disease progression. Quantifying these mechanical properties can thus be instrumental for medical diagnosis and for evaluation of tissue viability for transplant. However, soft and biological materials are exceptionally challenging to mechanically characterize using conventional testing methods, which are hindered by limitations of sample size, fixturing capabilities, and sample preparation. ObjectiveWe hypothesize that Volume Controlled Cavity Expansion (VCCE) is well-suited to capture subtle mechanical differences in biological tissue. The objective of this work is therefore twofold: first, we seek to quantify how stiffness of liver and gelatin evolve with age. In achieving this understanding, we aim to demonstrate the precision of VCCE in measuring subtle changes in the mechanical properties of biological tissues. MethodsPerforming VCCE tests over 15 days in samples of gelatin and liver (porcine and bovine), we track the evolving pressure-volume response and deformation limits of the materials. ResultsIn both materials, we observed time-dependent variation of the stiffness and fracture thresholds. In gelatin VCCE repeatably captured stiffening over time, which was correlated with a higher fracture stress. This was in contrast to observations in bovine liver, where stiffening corresponded to a lower fracture stress. Porcine liver initially stiffened, then reversed this trend and relaxed. ConclusionThrough this work we show that liver and gelatin stiffen with age, and that this trend is measurable via VCCE. These results highlight the utility of VCCE and call attention to the need for a new class of mechanism based constitutive models that are capable of capturing variations in material over time with a minimal number of parameters.

bioengineering↗

Elasticity of Whole Blood Clots Measured via Volume Controlled Cavity Expansion

Measuring and understanding the mechanical properties of blood clots can provide insights into disease progression and the effectiveness of potential treatments. However, several limitations hinder the use of standard mechanical testing methods to measure the response of soft biological tissues, like blood clots. These tissues can be difficult to mount, and are inhomogeneous, irregular in shape, scarce, and valuable. To remedy this, we employ in this work Volume Controlled Cavity Expansion (VCCE), a technique that was recently developed, to measure local mechanical properties of soft materials in their natural environment. Through a highly controlled volume expansion of a water bubble at the tip of an injection needle, paired with simultaneous measurement of the resisting pressure, we obtain a local signature of whole blood clot mechanical response. Comparing this data with predictive theoretical models, we find that a 1-term Ogden model is sufficient to capture the nonlinear elastic response observed in our experiments and produces shear modulus values that are comparable to values reported in the literature. Moreover, we find that bovine whole blood stored at 4{degrees}C for greater than 2 days exhibits a statistically significant shift in the shear modulus from 2.53 {+/-} 0.44 kPa on day 2 (N = 13) to 1.23 {+/-} 0.18 kPa on day 3 (N = 14). In contrast to previously reported results, our samples did not exhibit viscoelastic rate sensitivity within strain rates ranging from 0.22 - 21.1 s-1. By surveying existing data on whole blood clots for comparison, we show that this technique provides highly repeatable and reliable results, hence we propose the more widespread adoption of VCCE as a path forward to building a better understanding of the mechanics of soft biological materials. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=80 SRC="FIGDIR/small/528966v2_ufig1.gif" ALT="Figure 1"> View larger version (33K): org.highwire.dtl.DTLVardef@1cf427borg.highwire.dtl.DTLVardef@15d7b7org.highwire.dtl.DTLVardef@53ab4org.highwire.dtl.DTLVardef@1513aee_HPS_FORMAT_FIGEXP M_FIG C_FIG HighlightsO_LIVolume controlled cavity expansion overcomes common obstacles to testing biological samples C_LIO_LIWhole blood clot elasticity is well captured by the Ogden hyperelastic material model C_LIO_LIShear modulus strain-rate sensitivity was not observed in clots for moderate rates C_LI

bioengineering↗