bioRxiv Science⌕ Search

Biology subjects

Tunedal, K.

Publications and source records attributed to Tunedal, K..

3 recordsLinked to original sources

Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: identifying reliable biomarkers such as ventricular relaxation rate

Cardiovascular digital twins and mechanistic models can be used to obtain new biomarkers from patient-specific hemodynamic data. However, such model-derived biomarkers are only clinically relevant if the variation between timepoints/patients is smaller than the uncertainty of the biomarkers. Unfortunately, this uncertainty is challenging to calculate, as the uncertainty of the underlying hemodynamic data is largely unknown and has several sources that are not additive or normally distributed. This violates normality assumptions of current methods; implying that also biomarkers have an unknown uncertainty. To remedy these problems, we herein present a method, with attached code, for uncertainty calculation of model-derived biomarkers using non-normal data. First, we estimated all sources of uncertainty, both normal and non-normal, in hemodynamic data used to personalize an existing model; the errors in 4D flow MRI-derived stroke volumes were 5-20% and the blood pressure errors were 0{+/-}8 mmHg. Second, we estimated the resulting model-derived biomarker uncertainty for 100 simulated datasets, sampled from the data distributions, by: 1) combining data uncertainties 2) parameter estimation, 3) profile-likelihood. The true biomarker values were found within a 95% confidence interval in 98% (median) of the cases. This shows both that our estimated data uncertainty is reasonable, and that we can use profile-likelihood despite the non-normality. Finally, we demonstrated that e.g. ventricular relaxation rate has a smaller uncertainty ([~]10%) than the variation across a clinical cohort ([~]40%), meaning that these biomarkers have clinical usefulness. Our results take us one step closer to the usage of model-derived biomarkers for cardiovascular patient characterization. HighlightsO_LIDigital twin models provide physiological biomarkers using e.g. 4D-flow MRI data C_LIO_LIHowever, the data has several non-normal uncertainty components C_LIO_LIFor this reason, we do not know which biomarkers are reliable and clinically useful C_LIO_LINew method for data uncertainty and for calculation of biomarker uncertainty C_LIO_LIWe identified several reliable biomarkers: e.g. ventricular relaxation rate C_LI Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=77 SRC="FIGDIR/small/611398v1_ufig1.gif" ALT="Figure 1"> View larger version (28K): org.highwire.dtl.DTLVardef@c8a2forg.highwire.dtl.DTLVardef@14440d2org.highwire.dtl.DTLVardef@1fbab07org.highwire.dtl.DTLVardef@199764e_HPS_FORMAT_FIGEXP M_FIG C_FIG

systems biology↗

Reproducibility of 4D Flow MRI-based Personalized Cardiovascular Models; Inter-sequence, Intra-observer, and Inter-observer variability

Subject-specific parameters in lumped hemodynamic models of the cardiovascular system can be estimated using data from experimental measurements, but the parameter estimation may be hampered by the variability in the input data. In this study, we investigate the influence of inter-sequence, intra-observer, and inter-observer variability in input parameters on estimation of subject-specific model parameters using a previously developed approach for model-based analysis of data from 4D Flow MRI acquisitions and cuff pressure measurements. The parameters describe left ventricular time-varying elastance and aortic compliance. Parameter reproducibility with respect to variability in the MRI input measurements was assessed in a group of ten healthy subjects. The subject-specific parameters had coefficient of variations between 2.5% and 34.9% in the intra- and inter-observer analysis. In comparing parameters estimated using data from the two MRI sequences, the coefficients of variation ranged between 3.6% and 41%. The diastolic time constant of the left ventricle and the compliance of the ascending aorta were the parameters with the lowest and the highest variability, respectively. In conclusion, the modeling approach allows for estimating left ventricular elastance parameters and aortic compliance from non-invasive measurements with good to moderate reproducibility concerning intra-user, inter-user, and inter-sequence variability.

systems biology↗

Digital twins and hybrid modelling for simulation of physiological variables and stroke risk

One of the more interesting ideas for achieving personalized, preventive, and participatory medicine is the concept of a digital twin. A digital twin is a personalized computer model of a patient. So far, digital twins have been constructed using either mechanistic models, which can simulate the trajectory of physiological and biochemical processes in a person, or using machine learning models, which for example can be used to estimate the risk of having a stroke given a cross-section profile at a given timepoint. These two modelling approaches have complementary strengths which can be combined into a hybrid model. However, even though hybrid modelling combining mechanistic modelling and machine learning have been proposed, there are few, if any, real examples of hybrid digital twins available. We now present such a hybrid model for the simulation of ischemic stroke. On the mechanistic side, we develop a new model for blood pressure and integrate this with an existing multi-level and multi-timescale model for the development of type 2 diabetes. This mechanistic model can simulate the evolution of known physiological risk factors (such as weight, diabetes development, and blood pressure) through time, under different intervention scenarios, involving a change in diet, exercise, and certain medications. These forecast trajectories of the physiological risk factors are then used by a machine learning model to calculate the 5-year risk of stroke, which thus also can be calculated for each timepoint in the simulated scenarios. We discuss and illustrate practical issues with clinical implementation, such as data gathering and harmonization. By improving patients understanding of their body and health, the digital twin can serve as a valuable tool for patient education and as a conversation aid during the clinical encounter. As such, it can facilitate shared decision-making, promote behavior change towards a healthy lifestyle, and improve adherence to prescribed medications.

systems biology↗