bioRxiv Science⌕ Search

Biology subjects

Trebbin, M.

Publications and source records attributed to Trebbin, M..

3 recordsLinked to original sources

Novel polymer fixed-target microfluidic platforms with an ultra-thin moisture barrier for serial macromolecular crystallography

The advent of ultrabright fourth generation X-ray light sources, including X-ray free-electron lasers (XFELs) and diffraction limited synchrotrons, has significantly advanced the field of serial macromolecular protein crystallography (SX). SX experiments demand a continuous supply of fresh microcrystalline sample, ideally while minimizing overall sample consumption. Here, we introduce a novel, robust, and user-friendly polymer film technology that can be assembled in various configurations to encapsulate protein microcrystals and provide sample support for SX. This system provides an efficient hydration barrier over extended durations while maintaining an exceptionally low X-ray background. We have validated this technology by assessing hydration retention under both ambient and ultra-high vacuum conditions, and by evaluating its mechanical stability under XFEL pulses. Furthermore, we have demonstrated the effectiveness of this approach in two room-temperature serial crystallography studies to determine the structure of a 24 kDa Rapid Encystment Phenotype (REP24) protein from Franciscella tularensis.

biophysics↗

Need for speed: Examining protein behaviour during cryoEM grid preparation at different timescales

A host of new technologies are under development to improve the quality and reproducibility of cryoEM grid preparation. Here we have systematically investigated the preparation of three macromolecular complexes using three different vitrification devices (Vitrobot, chameleon and a time-resolved cryoEM device) on various timescales, including grids made within 6 ms, (the fastest reported to date), to interrogate particle behaviour at the air-water interface for different timepoints. Results demonstrate that different macromolecular complexes can respond to the thin film environment formed during cryoEM sample preparation in highly variable ways, shedding light on why cryoEM sample preparation can be difficult to optimise. We demonstrate that reducing time between sample application and vitrification is just one tool to improve cryoEM grid quality, but that it is unlikely to be a generic silver bullet for improving the quality of every cryoEM sample preparation.

biochemistry↗

A Cryo-EM Grid Preparation Device for Time-Resolved Structural Studies

Structural biology generally provides static snapshots of protein conformations that can inform on the functional mechanisms of biological systems. Time-resolved structural biology provides a means to visualise, at near-atomic resolution, the dynamic conformational changes that macromolecules undergo as they function. Recent advances in the resolution obtainable by electron microscopy (EM) and the broad range of samples that can be studied makes it ideally suited to time-resolved studies. Here we describe a cryo-electron microscopy grid preparation device that permits rapid mixing, voltage assisted spraying, and vitrification of samples. We show that the device produces grids of sufficient ice quality to enable data collection from single grids that results in a sub 4 [A] reconstruction. Rapid mixing can be achieved by blot and spray or mix and spray approaches with a delay of ~10 ms, providing greater temporal resolution than previously reported approaches.

biophysics↗