bioRxiv Science⌕ Search

Biology subjects

Tierney, T. M.

Publications and source records attributed to Tierney, T. M..

17 recordsLinked to original sources

Modular Arrays for High Precision Wearable MEG

Optically pumped magnetometers (OPMs) can be used for magnetoencephalography (MEG) with equivalent or improved signal to noise ratio, relative to cryogenic MEG, when sensors are placed close to the scalp. OPM-based MEG can also be used in mobile contexts if sensors are placed in lightweight, wearable arrays. Individually tailored, rigid helmets known as scannercasts are currently the only method capable of achieving on-scalp, mobile recordings with high precision. However, these scannercasts are expensive to produce, require structural imaging in advance of the experiment, and can incur lengthy downtime while sensors are transferred between scannercasts. Here, we introduce a solution to these challenges that retains the advantages of scannercasts. We provide detailed steps for constructing a modular, cap-based design, suitable for all head sizes. Using simulations, we compare the leadfield power of this array against an idealised array and a commercially available mobile solution. We then validate our proposed solution empirically, in five participants, and provide a complete data preparation and analysis pipeline. Our design expands the accessibility of OPM-based MEG, and increases participant throughput to levels comparable to other imaging modalities. Crucially, it removes the trade-off between signal quality, mobility and practicality, promoting the unique potential of OPM-based MEG as a tool for studying naturalistic behaviour, and clinical assessment with high precision.

neuroscience↗

Magnetoencephalography Without a Shielded Room

Magnetoencephalography (MEG) offers non-invasive neuroimaging with high temporal and spatial precision - but its adoption is hampered by the prohibitive cost and infrastructure burden of a magnetically shielded room. We have overcome that burden and present a lightweight, low-cost, multichannel magnetoencephalography system that can image brain activity without needing a magnetically shielded room. The multichannel nature of the system facilitates not just detection but also localization of brain signals that are over 300 million times smaller than environmental interference, without requiring passive shielding. Our system weighs less than 75kg, more than 100 times lighter than a typical shielded room. This is made possible through low-cost active shielding and software-based spatial filtering. We also show that the signal to noise ratio of our in-vivo recordings is comparable to what can be obtained from a conventional cryogenically-cooled MEG system sited within a shielded room. This demonstration is a crucial step towards democratizing magnetoencephalography and making it a globally accessible neuroimaging technology for healthcare and discovery research.

neuroscience↗

Wearable MEG data recorded during human stepping

Non-invasive spatiotemporal imaging of brain activity during large-scale, whole body movement is a significant methodological challenge for the field of movement neuroscience. Here, we present a dataset recorded using a new imaging modality - optically-pumped magnetoencephalography (OP-MEG) - to record brain activity during human stepping. Participants (n=3) performed a visually guided stepping task requiring precise foot placement while dual-axis and triaxial OP-MEG and leg muscle activity (electromyography, EMG) were recorded. The dataset also includes a structural MRI for each participant and foot kinematics. We validate the fidelity of the OPM data by showing movement-related beta band desynchronization source localised to the primary motor cortex. This multimodal dataset offers a resource for methodological development and testing for OPM data (e.g., movement-related interference rejection), within-subject analyses, and exploratory analyses to generate hypotheses for further work on the neural control of human stepping.

neuroscience↗

Non-invasive evidence for rhythmic interactions between the human brain, spinal cord, and muscle

Voluntary human movement relies on interactions between the spinal cord, brain, and sensory afferents. The integrative function of the spinal cord has proven particularly difficult to study directly and non-invasively in humans due to challenges in measuring spinal cord activity. Investigations of sensorimotor integration often rely on cortico-muscular coupling, which can capture interactions between the brain and muscle, but cannot reveal how the spinal cord mediates this communication. Here, we introduce a system for direct, non-invasive imaging of concurrent brain and cervical spinal cord activity in humans using optically-pumped magnetometers (OPMs). We used this system to study endogenous interactions between the brain, spinal cord, and muscle involved in sensorimotor control during simple maintained contraction. Participants (n=3) performed a hand contraction with real-time visual feedback while we recorded brain and spinal cord activity using OPMs and muscle activity using EMG. We first identify the part of the spinal cord exhibiting a peak in estimated current flow in the cervical region during contraction. We then demonstrate that rhythmic activity in the spinal cord exhibits significant coupling with both brain and muscle activity in the 5-35 Hz frequency range. These findings evidence the possibility of concurrent spatio-temporal imaging along the entire neuro-axis.

neuroscience↗

Adaptive multipole models of OPM data.

Multipole expansions have been used extensively in the Magnetoencephalography (MEG) literature for mitigating environmental interference and modelling brain signal. However, their application to Optically Pumped Magnetometer (OPM) data is challenging due to the wide variety of existing OPM sensor and array designs. We therefore explore how such multipole models can be adapted to provide stable models of brain signal and interference across OPM systems. Firstly, we demonstrate how prolate spheroidal (rather than spherical) harmonics can provide a compact representation of brain signal when sampling on the scalp surface with as few as 100 channels. We then introduce a type of orthogonal projection incorporating this basis set, the Adaptive Multipole Models (AMM), which provides robust interference rejection across systems, even in the presence of spatially structured nonlinearity errors. This projection is always stable, as it is an orthogonal projection, and will only ever decrease the white noise in the data. However, for array designs that are suboptimal for spatially separating brain signal and interference, this method can remove brain signal components. We contrast these properties with the more typically used multipole expansion, Signal Space Separation (SSS), which never reduces brain signal amplitude but is less robust to the effect of sensor nonlinearity errors on interference rejection and can increase noise in the data if the system is sub-optimally designed (as it is an oblique projection). We conclude with an empirical example utilizing AMM to maximize signal to noise ratio (SNR) for the stimulus locked neuronal response to a flickering visual checkerboard in a 128-channel OPM system and demonstrate up to 40dB software shielding in real data.

neuroscience↗

Combining video telemetry and wearable MEG for naturalistic imaging

Neuroimaging studies have typically relied on rigorously controlled experimental paradigms to probe cognition, in which movement is restricted, primitive, an afterthought or merely used to indicate a subjects choice. Whilst powerful, these paradigms do not often resemble how we behave in everyday life, so a new generation of ecologically valid experiments are being developed. Magnetoencephalography (MEG) measures neural activity by sensing extracranial magnetic fields. It has recently been transformed from a large, static imaging modality to a wearable method where participants can move freely. This makes wearable MEG systems a prime candidate for naturalistic experiments going forward. However, these experiments will also require novel methods to capture and integrate information about complex behaviour executed during neuroimaging, and it is not yet clear how this could be achieved. Here we use video recordings of multi-limb dance moves, processed with open-source machine learning methods, to automatically identify analysis time windows of interest in concurrent wearable MEG data. In a first step, we compare a traditional, block-designed analysis of limb movements, where the times of interest are based on stimulus presentation, to an analysis pipeline based on hidden Markov model states derived from the video telemetry. Next, we show that it is possible to identify discrete modes of neuronal activity related to specific limbs and body posture by processing the participants choreographed movement in a dancing paradigm. This demonstrates the potential of combing video telemetry with mobile neuroimaging for future studies of complex and naturalistic behaviours.

neuroscience↗

Is high-frequency activity evidence of an anterior temporal lobe network or micro-saccades?

There is renewed interest in electrical activity that extends beyond the typical electrophysiological 100 Hz bandwidth. This activity, often in the anterior temporal lobe, has been attributed to processes ranging from memory consolidation to epileptiform activity. Here, using an open-access resting state magnetoencephalography (MEG) dataset (n = 89), and a second task-based MEG dataset, we could reliably localise high-frequency power to the temporal lobes across multiple bands up to 300-400 Hz. A functional connectivity analysis of this activity revealed a robust resting state bilateral network between the temporal lobes. However, we also found robust coherence in the 100-200 and 200-300 Hz bands between source reconstructed MEG data and the electrooculography (EOG) localised to within the temporal poles. Additional denoising schemes applied to the data could reduce power localisation to the temporal poles but the topography of the functional network did not drastically alter. Whilst it is clear that this network is biological and robust to established denoising methods, we cannot definitively rule yet on whether this is of neural or myogenic origin.

neuroscience↗

Neural activity in human eyeblink conditioning: an optically pumped magnetometer-based MEG study

There is a profound lack of electrophysiological data from the cerebellum in humans, as compared to animals, because the pervading perception is that it is difficult to record human cerebellar activity non-invasively using magnetoencephalography (MEG) or electroencephalography (EEG). We used on-scalp MEG based on optically pumped magnetometers (OP-MEG) to detect learning related cerebellar signals in a classical eyeblink conditioning paradigm. In four healthy human adults, we observed unconditioned stimulus-related evoked responses locating in the cerebellum. These evoked responses diminished during the acquisition of conditioned responses, which corresponds with previous observed changes of Purkinje cell activities in animals. We also observed evoked responses immediately before conditioned blinks in 3 out of 4 participants, which were also located in the cerebellum. We discuss the potential nature of these cerebellar evoked responses and future applications of OP-MEG to the studies of human cerebellar physiology.

neuroscience↗

Concurrent spinal and brain imaging with optically pumped magnetometers

The spinal cord and its interactions with the brain are fundamental for movement control and somatosensation. However, brain and spinal cord electrophysiology in humans have largely been treated as distinct enterprises, in part due to the relative inaccessibility of the spinal cord. Consequently, there is a dearth of knowledge on human spinal electrophysiology, including the multiple pathologies of the central nervous system that affect the spinal cord as well as the brain. Here we exploit recent advances in the development of wearable optically pumped magnetometers (OPMs) which can be flexibly arranged to provide coverage of both the spinal cord and the brain concurrently in unconstrained environments. Our system for magnetospinoencephalography (MSEG) measures both spinal and cortical signals simultaneously by employing a custom-made spinal scanning cast. We evidence the utility of such a system by recording simultaneous spinal and cortical evoked responses to median nerve stimulation, demonstrating the novel ability for concurrent non-invasive millisecond imaging of brain and spinal cord.

neuroscience↗

Spherical harmonic based noise rejection and neuronal sampling with multi-axis OPMs

In this study we explore the interference rejection and spatial sampling properties of multi-axis Optically Pumped Magnetometer (OPM) data. We use both vector spherical harmonics and eigenspectra to quantify how well an array can separate neuronal signal from environmental interference while adequately sampling the entire cortex. We found that triaxial OPMs have superb noise rejection properties allowing for very high orders of interference (L=6) to be accounted for while minimally affecting the neural space (2dB attenuation for a 60-sensor triaxial system). To adequately model the signals arising from the cortex, we show that at least 11th order (143 spatial degrees of freedom) irregular solid harmonics or 95 eigenvectors of the lead field are needed to model the neural space for OPM data (regardless of number of axes measured). This can be adequately sampled with 75-100 equidistant triaxial sensors (225-300 channels) or 200 equidistant radial channels. In other words, ordering the same number of channels in triaxial (rather than purely radial) configuration gives significant advantages not only in terms of external noise rejection but also minimizes cost, weight and cross-talk.

neuroscience↗

Using OPMs to measure neural activity in standing, mobile participants

Optically pumped magnetometer-based magnetoencephalography (OP-MEG) can be used to measure neuromagnetic fields while participants move in a magnetically shielded room. Head movements in previous OP-MEG studies have been up to 20 cm translation and [~]30{degrees} rotation in a sitting position. While this represents a step-change over stationary MEG systems, naturalistic head movement is likely to exceed these limits, particularly when participants are standing up. In this proof-of-concept study, we sought to push the movement limits of OP-MEG even further. Using a 90 channel (45-sensor) whole-head OP-MEG system and concurrent motion capture, we recorded auditory evoked fields while participants were: (i) sitting still, (ii) standing up and still, and (iii) standing up and making large natural head movements continuously throughout the recording - maximum translation 120 cm, maximum rotation 198{degrees}. Following pre-processing, movement artefacts were substantially reduced but not eliminated. However, upon utilisation of a beamformer, the M100 event-related field localised to primary auditory regions. Furthermore, the event-related fields from auditory cortex were remarkably consistent across the three conditions. These results suggest that a wide range of movement is possible with current OP-MEG systems. This in turn underscores the exciting potential of OP-MEG for recording neural activity during naturalistic paradigms that involve movement (e.g. navigation), and for scanning populations who are difficult to study with stationary MEG (e.g. young children).

neuroscience↗

Magnetic Field Mapping and Correction for Moving OP-MEG

BackgroundOptically pumped magnetometers (OPMs) have made moving, wearable magnetoencephalography (MEG) possible. The OPMs typically used for MEG require a low background magnetic field to operate, which is achieved using both passive and active magnetic shielding. However, the background magnetic field is never truly zero Tesla, and so the field at each of the OPMs changes as the participant moves. This leads to position and orientation dependent changes in the measurements, which manifest as low frequency artefacts in MEG data. ObjectiveWe modelled the spatial variation in the magnetic field and used the model to predict the movement artefact found in a dataset. MethodsWe demonstrate a method for modelling this field with a triaxial magnetometer, then showed that we can use the same technique to predict the movement artefact in a real OPM-based MEG (OP-MEG) dataset. ResultsUsing an 86-channel OP-MEG system, we found that this modelling method maximally reduced the power spectral density of the data by 26.2 {+/-} 0.6 dB at 0 Hz, when applied over 5 s non-overlapping windows. ConclusionThe magnetic field inside our state-of-the art magnetically shielded room can be well described by low-order spherical harmonic functions. We achieved a large reduction in movement noise when we applied this model to OP-MEG data. SignificanceReal-time implementation of this method could reduce passive shielding requirements for OP-MEG recording and allow the measurement of low-frequency brain activity during natural participant movement.

neuroscience↗

Testing covariance models for MEG source reconstruction of hippocampal activity

Beamforming is one of the most commonly used source reconstruction methods for magneto- and electroencephalography (M/EEG). One underlying assumption, however, is that distant sources are uncorrelated and here we tested whether this is an appropriate model for the human hippocampal data. We revised the Empirical Bayesian Beamfomer (EBB) to accommodate specific a-priori correlated source models. We showed in simulation that we could use model evidence (as approximated by Free Energy) to distinguish between different correlated and uncorrelated source scenarios. Using group MEG data in which the participants performed a hippocampal-dependent task, we explored the possibility that the hippocampus or the cortex or both were correlated in their activity across hemispheres. We found that incorporating a correlated hippocampal source model significantly improved model evidence. Our findings help to explain why, up until now, the majority of MEG-reported hippocampal activity (typically making use of beamformers) has been estimated as unilateral.

neuroscience↗

Modelling optically pumped magnetometerinterference as a mean (magnetic) field

Here we propose that much of the magnetic interference observed when using optically pumped magnetometers can be modeled spatially as a mean (magnetic) field. We show that this approximation reduces sensor level variability and substantially improves statistical power. This model does not require knowledge of the underlying neuroanatomy nor the sensor positions. It only needs information about the sensor orientation. Due to the models low rank there is little risk of removing substantial neural signal. However, we provide a framework to assess this risk for any sensor number, design or subject neuroanatomy. We find that the risk of unintentionally removing neural signal is reduced when multi-axis recordings are performed. We validated the method using a binaural auditory evoked response paradigm and demonstrated that the mean field correction increases reconstructed SNR in relevant brain regions in both the spatial and temporal domain. Considering the models simplicity and efficacy, we suggest that this mean field correction can be a powerful preprocessing step for arrays of optically pumped magnetometers.

neuroscience↗

Mouth magnetoencephalography: A unique perspective on the human hippocampus

Traditional magnetoencephalographic (MEG) brain imaging scanners consist of a rigid sensor array surrounding the head; this means that they are maximally sensitive to superficial brain structures. New technology based on optical pumping means that we can now consider more flexible and creative sensor placement. Here we explored the magnetic fields generated by a model of the human hippocampus not only across scalp but also at the roof of the mouth. We found that simulated hippocampal sources gave rise to dipolar field patterns with one scalp surface field extremum at the temporal lobe and a corresponding maximum or minimum at the roof of the mouth. We then constructed a fitted dental mould to accommodate an Optically Pumped Magnetometer (OPM). We collected data using a previously validated hippocampal-dependent task to test the empirical utility of a mouth-based sensor, with an accompanying array of left and right temporal lobe OPMs. We found that the mouth sensor showed the greatest task-related theta power change. We also found that, as predicted by the simulations, the mouth sensor was anti-correlated with those on over the temporal lobes. We found that this sensor had a mild effect on the reconstructed power in the hippocampus (~10% change) but that coherence images between the mouth sensor and reconstructed source images showed a global maximum in the right hippocampus. We conclude that augmenting a scalp-based MEG array with sensors in the mouth shows unique promise for both basic scientists and clinicians interested in interrogating the hippocampus.

neuroscience↗

Pragmatic spatial sampling for wearable MEG arrays

Several new technologies have recently emerged promising new MEG systems in which the sensors can be placed close to the scalp. One such technology, Optically Pumped Magnetometry MEG (OP-MEG) allows for a scalp mounted flexible system that provides field measurements within mm of the scalp surface. A question that arises in developing on-scalp systems, such as OP-MEG scanners, is: how many sensors are necessary to achieve adequate performance/spatial discrimination? There are many factors to consider in answering this question such as the signal to noise ratio (SNR), the locations and depths of the sources of interest, the density of spatial sampling, sensor gain errors (due to interference, subject movement, cross-talk, etc.) and, of course, the desired spatial discrimination. In this paper, we provide simulations which show the impact these factors have on designing sensor arrays for wearable MEG. While OP-MEG has the potential to provide high information content at dense spatial samplings, we find that adequate spatial discrimination of sources (<1cm) can be achieved with relatively few sensors (<100) at coarse spatial samplings (~30mm) at high SNR. Comparable discrimination for traditional cryogenic systems require far more channels by these same metrics. Finally we show that sensor gain errors have the greatest impact on discrimination between deep sources at high SNR.

neuroscience↗

Using optically-pumped magnetometers to measure magnetoencephalographic signals in the human cerebellum

We test the feasibility of an optically pumped magnetometer (OPM)-MEG system for the measurement of human cerebellar activity. We show that the OPM system allows for excellent coverage of this structure by decreasing the average sensor-to-cerebellum distance by around 33% (16mm), compared to a standard MEG helmet. This closer proximity to the cerebellum approximately doubles the signal-to-noise ratio (SNR). As a proof of principle, we used an air-puff stimulus to the eyeball in order to elicit cerebellar evoked and induced responses that are well characterized in non-human models. In three subjects, we observed an evoked component at 50ms post stimulus, which originates in the cerebellum (predominantly ipsilateral). This response was followed by a second component at 100ms post stimulus (predominantly contra-lateral). Sensory stimulation also elicited an event-related broadband spectral power change in the ipsilateral cerebellum at ~100ms in all subjects. We conclude that the OPM-MEG technology offers a promising way to advance the understanding of the information processing mechanisms in the human cerebellum.

neuroscience↗