bioRxiv Science⌕ Search

Biology subjects

Teo, G. C.

Publications and source records attributed to Teo, G. C..

9 recordsLinked to original sources

Spatial distribution of the proteome in human body and cancers

A comprehensive spatial distribution of the proteome in human body and cancers is fundamental for understanding human biology and diseases including cancers. Here, we present an anatomically resolved human proteome derived from 1781 benign and malignant samples from 58 major tissue types encompassing 251 specific tissues and 25 carcinomas. Based on a spectral library covering over 75% of the human protein-coding genes with 208 understudied and 82 missing proteins characterized, we quantified over 13,000 proteins in these samples using data-independent acquisition proteomics. This data resource presents the so far most comprehensive quantitative proteomic landscape of human tissues and common carcinomas. It allows systematic evaluation of tissue-specific drug responses, identification of drug candidates that may be repurposed as antineoplastics, and discovery of novel targets for anticancer therapy. This resource, available as an online knowledgebase, refines our knowledge of spatial distribution of the human proteome and tumor-specific protein modulation.

systems biology↗

diaTracer enables spectrum-centric analysis of diaPASEF proteomics data

Data-independent acquisition (DIA) has become a widely used strategy for peptide and protein quantification in mass spectrometry-based proteomics studies. The integration of ion mobility separation into DIA analysis, such as the diaPASEF technology available on Brukers timsTOF platform, further improves the quantification accuracy and protein depth achievable using DIA. We introduce diaTracer, a new spectrum-centric computational tool optimized for diaPASEF data. diaTracer performs three-dimensional (m/z, retention time, ion mobility) peak tracing and feature detection to generate precursor-resolved "pseudo-MS/MS" spectra, facilitating direct ("spectral-library free") peptide identification and quantification from diaPASEF data. diaTracer is available as a stand-alone tool and is fully integrated into the widely used FragPipe computational platform. We demonstrate the performance of diaTracer and FragPipe using diaPASEF data from triple-negative breast cancer (TNBC), cerebrospinal fluid (CSF), and plasma samples, data from phosphoproteomics and HLA immunopeptidomics experiments, and low-input data from a spatial proteomics study. We also show that diaTracer enables unrestricted identification of post-translational modifications from diaPASEF data using open/mass-offset searches.

bioinformatics↗

One-stop analysis of DIA proteomics data using MSFragger-DIA and FragPipe computational platform

Liquid chromatography (LC) coupled with data-independent acquisition (DIA) mass spectrometry (MS) has been increasingly used in quantitative proteomics studies. Here, we present a fast and sensitive approach for direct peptide identification from DIA data, MSFragger-DIA, which leverages the unmatched speed of the fragment ion indexing-based search engine MSFragger. MSFragger-DIA conducts a database search of the DIA tandem mass (MS/MS) spectra prior to spectral feature detection and peak tracing across the LC dimension. We have integrated MSFragger-DIA into the FragPipe computational platform for seamless support of peptide identification and spectral library building from DIA, data dependent acquisition (DDA), or both data types combined. We compared MSFragger-DIA with other DIA tools, such as DIA-Umpire based workflow in FragPipe, Spectronaut, and in silico library-based DIA-NN and MaxDIA. We demonstrated the fast and sensitive performance of MSFragger-DIA across a variety of sample types and data acquisition schemes, including single-cell proteomics, phosphoproteomics, and large-scale tumor proteome profiling studies.

bioinformatics↗

MSBooster: Improving Peptide Identification Rates using Deep Learning-Based Features

Peptide identification in liquid chromatography-tandem mass spectrometry (LC-MS/MS) experiments relies on computational algorithms for matching acquired MS/MS spectra against sequences of candidate peptides using database search tools, such as MSFragger. Here, we present a new tool, MSBooster, for rescoring peptide-to-spectrum matches using additional features incorporating deep learning-based predictions of peptide properties, such as LC retention time, ion mobility, and MS/MS spectra. We demonstrate the utility of MSBooster, in tandem with MSFragger and Percolator, in several different workflows, including nonspecific searches (immunopeptidomics), direct identification of peptides from data independent acquisition data, single-cell proteomics, and data generated on an ion mobility separation-enabled timsTOF MS platform. MSBooster is fast, robust, and fully integrated into the widely used FragPipe computational platform.

bioinformatics↗

MSFragger-Labile: A Flexible Method to Improve Labile PTM Analysis in Proteomics

Post-translational modifications of proteins play essential roles in defining and regulating the functions of the proteins they decorate, making identification of these modifications critical to understanding biology and disease. Methods for enriching and analyzing a wide variety of biological and chemical modifications of proteins have been developed using mass spectrometry (MS)-based proteomics, largely relying on traditional database search methods to annotate resulting mass spectra of modified peptides. These database search methods treat modifications as static attachments of a mass to particular position in the peptide sequence, but many modifications undergo fragmentation in tandem MS experiments alongside, or instead of, the peptide backbone. While this fragmentation can confound traditional search methods, it also offers unique opportunities for improved searches that incorporate modification-specific fragment ions. Here, we present a new Labile Mode in the MSFragger search engine that can tailor modification-centric searches to the fragmentation observed. We show that labile mode can dramatically improve spectrum annotation rates of phosphopeptides, RNA-crosslinked peptides, and ADP-ribosylated peptides. Each of these modifications presents distinct fragmentation characteristics, showcasing the flexibility of MSFragger labile mode to improve search for a wide variety of biological and chemical modifications.

bioinformatics↗

Uncovering the modified immunopeptidome reveals insights into principles of PTM-driven antigenicity

Antigen processing and presentation are critical for modulating tumor-host interactions. While post-translational modifications (PTMs) can alter the binding and recognition of antigens, their identification remains challenging. Here we uncover the role PTMs may play in antigen presentation and recognition in human cancers by profiling 29 different PTM combinations in immunopeptidomics data from multiple clinical samples and cell lines. We established and validated an antigen discovery pipeline and showed that newly identified modified antigens from a murine cancer model are cancer-specific and can elicit T cell killing. Systematic analysis of PTMs across multiple cohorts defined new haplotype preferences and binding motifs in association with specific PTM types. By expanding the antigenic landscape with modifications, we uncover disease-specific targets, including thousands of novel cancer-specific antigens and reveal insight into PTM-driven antigenicity. Collectively, our findings highlight an immunomodulatory role for modified peptides presented on HLA I, which may have broad implications for T-cell mediated therapies in cancer and beyond. SignificanceMajor efforts are underway to identify cancer-specific antigens for personalized immunotherapy. Here, we enrich the immunopeptidome landscape by uncovering thousands of novel putative antigens that are post-translationally modified. We define unique preferences for PTM-driven alterations affecting HLA binding and TCR recognition, which in turn alter tumor-immune interactions. Conflict of interest statementAuthors declare no conflicts of interest.

cancer biology↗

High sensitivity dia-PASEF proteomics with DIA-NN and FragPipe

The dia-PASEF technology exploits ion mobility separation for high-sensitivity analysis of complex proteomes. Here, we demonstrate neural network-based processing of the ion mobility data, which we implement in the DIA-NN software suite. Using spectral libraries generated with the MSFragger-based FragPipe computational platform, the DIA-NN analysis of dia-PASEF raw data increases the proteomic depth by up to 69% compared to the originally published dia-PASEF workflow. For example, we quantify over 5200 proteins from 10ng of HeLa peptides separated with a 95-minute nanoflow gradient, and over 5000 proteins from 200ng using a 4.8-minute separation with an Evosep One system. In complex samples, featuring a mix of human and yeast lysates, the workflow detects over 11700 proteins in single runs acquired with a 100-minute nanoflow gradient, while demonstrating quantitative precision. Hence, the combination of FragPipe and DIA-NN provides a simple-to-use software platform for dia-PASEF data analysis, yielding significant gains in high-sensitivity proteomics.

bioinformatics↗

Fast and Comprehensive N- and O-glycoproteomics analysis with MSFragger-Glyco

Glycosylation is a ubiquitous and heterogeneous post-translational modification (PTM) used to accomplish a wide variety of critical cellular tasks. Recent advances in methods for enrichment and mass spectrometric analysis of intact glycopeptides have produced large-scale, high-quality glycoproteomics datasets, but interpreting this data remains challenging. In addition to being large, complex, and heterogeneous, glycans undergo fragmentation during vibrational activation, making common PTM search strategies ineffective for their identification. We present a computational tool called MSFragger-Glyco for fast and highly sensitive identification of N- and O-linked glycopeptides using open and glycan mass offset search strategies. Reanalysis of recently published N-glycoproteomics data resulted in annotation of 83% more glycopeptide-spectrum matches (glycoPSMs) than in previous results, which translated to substantial increases in the numbers of glycoproteins and glycosites that could be identified. In published O-glycoproteomics data, our method more than doubled the number of glycoPSMs annotated when searching the same peptides as the original search and resulted in up to a 6-fold increase when expanding searches to include large numbers of possible glycan compositions and other modifications. Expanded searches revealed trends in glycan composition and crosstalk with phosphorylation that remained hidden to the original search. With greatly improved spectral annotation, coupled with the fast speed of fragment ion index-based scoring, MSFragger-Glyco makes it possible to comprehensively interrogate glycoproteomics data and illuminate the many roles of glycosylation.

bioinformatics↗

Fast quantitative analysis of timsTOF PASEF data with MSFragger and IonQuant

Ion mobility brings an additional dimension of separation to liquid chromatography-mass spectrometry, improving identification of peptides and proteins in complex mixtures. A recently introduced timsTOF mass spectrometer (Bruker) couples trapped ion mobility separation to time-of-flight mass analysis. With the parallel accumulation serial fragmentation (PASEF) method, the timsTOF platform achieves promising results, yet analysis of the data generated on this platform represents a major bottleneck. Currently, MaxQuant and PEAKS are most commonly used to analyze these data. However, due to the high complexity of timsTOF PASEF data, both require substantial time to perform even standard tryptic searches. Advanced searches (e.g. with many variable modifications, semi- or non-enzymatic searches, or open searches for post-translational modification discovery) are practically impossible. We have extended our fast peptide identification tool MSFragger to support timsTOF PASEF data, and developed a label-free quantification tool, IonQuant, for fast and accurate 4-D feature extraction and quantification. Using a HeLa data set published by Meier et al. (2018), we demonstrate that MSFragger identifies significantly (∼30%) more unique peptides than MaxQuant (1.6.10.43), and performs comparably or better than PEAKS X+ (∼10% more peptides). IonQuant outperforms both in terms of number of quantified proteins while maintaining good quantification precision and accuracy. Runtime tests show that MSFragger and IonQuant can fully process a typical two-hour PASEF run in under 70 minutes on a typical desktop (6 CPU cores, 32 GB RAM), significantly faster than other tools. Finally, through semi-enzymatic searching, we significantly increase the number of identified peptides. Within these semi-tryptic identifications, we report evidence of gas-phase fragmentation prior to MS/MS analysis.Competing Interest StatementThe authors have declared no competing interest.AbbreviationsLC-MSliquid chromatography-mass spectrometryTIMStrapped ion mobility spectrometryTOFtime-of-flightPASEFparallel accumulation-serial fragmentationDDAdata-dependent acquisitionDIAdata-independent acquisitionMS/MStandem mass spectrometryPSMpeptide-spectrum matchLC-IMS-MSliquid chromatography-ion mobility-mass spectrometryXICextracted ion chromatogramCVcoefficient of variationLFQlabel free quantificationFDRFalse Discovery RateCIDcollision-induced dissociationCPUcentral processing unitPTMpost-translational modificationMBRmatch-between-runsView Full Text

bioinformatics↗