bioRxiv Science⌕ Search

Biology subjects

Tamburro, D.

Publications and source records attributed to Tamburro, D..

2 recordsLinked to original sources

Analytical Performance of a Standardized Kit for Mass Spectrometry-based Measurements of Human Glycosaminoglycans

Glycosaminoglycans (GAGs) are long linear sulfated polysaccharides implicated in processes linked to disease development such as mucopolysaccharidosis, respiratory failure, cancer, and viral infections, thereby serving as potential biomarkers. A successful clinical translation of GAGs as biomarkers depends on the availability of standardized GAG measurements. However, owing to the analytical complexity associated with the quantification of GAG concentration and structural composition, a standardized method to simultaneously measure multiple GAGs is missing. In this study, we sought to characterize the analytical performance of a ultra-high-performance liquid chromatography coupled with triple-quadrupole tandem mass spectrometry (UHPLC-MS/MS)-based kit for the quantification of 17 GAG disaccharides. The kit showed acceptable linearity, selectivity and specificity, accuracy and precision, and analyte stability in the absolute quantification of 15 GAG disaccharides. In native human samples, here using urine as a reference matrix, the analytical performance of the kit was acceptable for the quantification of CS disaccharides. Intra- and inter-laboratory tests performed in an external laboratory demonstrated robust reproducibility of GAG measurements showing that the kit was acceptably standardized. In conclusion, these results indicated that the UHPLC-MS/MS kit was standardized for the simultaneous measurement of GAG disaccharides allowing for comparability of measurements and enabling translational research. SummaryAnalytical performance of a kit for standardized GAG measurements, based on an established UHPLC-MS/MS method

biochemistry↗

Mass spectrometry based qualification ofantibodies for plasma proteomics.

There is a strong need for procedures that enable context and application dependent validation of antibodies. Here we describe the foundation for a resource aiding more detailed assessment antibody selectivity for capturing endogenous proteins from human plasma. In 414 immunoprecipitation (IP) experiments with EDTA plasma, data was generated by mass spectrometry (LC-MS) with 157 antibodies (targeting 120 unique proteins). Out of a total of 1,313 unique proteins, 426 proteins (33%) were detected in > 20% of the assays and indicate a background comprised of mainly proteins from the complement system. For all proteins identified either in heat-treated or untreated EDTA plasma, frequencies of occurrence were derived. We determined z-scores for each IP as a measure of enrichment to annotate the antibodies into four categories (ON-target, CO-target, OFF-target and NO-target). For 45% (70/157) of the tested antibodies, the expected target proteins were enriched (z-score [≥]3) above background. There were 84% (59/70) of binders that co-enriched other proteins beside the intended target, either due to OFF-target binding or predicted interactions. Comparing several antibodies raised against IGFBP2, the established library allowed us to describe protein complexes in plasma, and we employed multiplexed sandwich immunoassays to confirm these. In summary, the generated resource of plasma enrichment profiles and background proteins adds a very useful and yet lacking starting point for the assessment of antibody selectivity in this clinically important body fluid. The provided insights will contribute to a more informed use of validated affinity reagents and may lead to further advancements of plasma proteomics assays.

biochemistry↗