bioRxiv ScienceSearch

Biology subjects

Sugerman, G. P.

Publications and source records attributed to Sugerman, G. P..

3 recordsLinked to original sources

The tricuspid valve also maladapts: A multiscale study in sheep with biventricular heart failure

ObjectivesWe set out to determine the tricuspid valves propensity to (mal)adapt in disease. BackgroundTricuspid regurgitation (TR) is generally considered secondary to right and/or left ventricular disease without organic failure. Interestingly, we and others have previously shown the mitral valve (mal)adapts in functional mitral regurgitation, which may warrant reconsideration of its functional etiology. Whether the tricuspid valve similarly (mal)adapts is mostly unknown. MethodsWe evaluated the (mal)adaptive response of tricuspid valve anterior leaflets (TVALs) from an ovine model in which over-pacing (19 {+/-} 6 days) induced biventricular heart failure and TR (tachycardia-induced cardiomyopathy, TIC, n=33) and compared findings to those from a control group (n=17). In both groups, we performed proteomics, immunohistochemistry, histology, two-photon microscopy, collagen assays, leaflet thickness and morphology measurements, and biaxial mechanical tests. ResultsWe found metabolically active resident valvular cells in TIC TVALs which expressed activation and turnover markers. In TIC TVALs, we observed a 140% increase in collagen content (p=0.016), increased collagen dispersion regionally (p=0.017), a 130% increase in leaflet area (p=0.002), a 140% increase in thickness (p=0.006), and a 130% increase in radial stiffness (p=0.006). ConclusionsOur data suggest that TVALs (mal)adapt during TIC on all scales. This response is likely initiated by activated valvular cells, resulting in collagen turnover, and ultimately leading to thickening, area increase, and stiffening. Our data motivates future studies on the exact pathways leading to tricuspid (mal)adaptation and pharmacological therapeutic strategies for TR. Condensed AbstractIn most cases, tricuspid regurgitation is presumed to originate from valve extrinsic factors. We challenge this paradigm and hypothesize that the tricuspid valve maladapts, rendering the valve at least partially culpable for its dysfunction. As such, we set out to demonstrate that the tricuspid valve, indeed, maladapts in an ovine model of heart disease. In the anterior leaflets, we found alterations on the protein and cell-level, leading to maladaptation in the form of tissue growth, thickening, and stiffening. Our findings may initially motivate mechanistic pathway studies, and in the future, leaflet-targeted pharmacological therapeutic options for tricuspid regurgitation.

bioengineering

A Whole Blood Thrombus Mimic: Constitutive Behavior Under Simple Shear

Deep vein thrombosis and pulmonary embolism affect 300,000-600,000 patients each year in the US. The progression from deep vein thrombus to pulmonary embolism occurs when blood clots, as a whole or partially, break off from the deep veins and eventually occlude the pulmonary arteries. Venous thromboembolism is the cause of up to 100,000 deaths per year in the US alone. To date, we dont fully understand this mechanical process among other reasons because in-vivo samples are difficult to obtain, highly heterogeneous, and their shapes are inappropriate for most mechanical tests. Toward overcoming these obstacles, we have set out to develop an in-vitro thrombus mimic and to test this mimic under large deformation simple shear. In addition to reporting on the mechanics of our mimics under simple shear, we explore the sensitivity of their mechanics to coagulation conditions and blood storage time, and compare three hyperelastic material models for their ability to fit our data. We found that thrombus mimics made from whole blood demonstrate strain-stiffening, a negative Poynting effect, and hysteresis when tested quasi-statically to 50% strain under simple shear. Additionally, we found that the stiffness of these mimics does not significantly vary with coagulation conditions or blood storage times. Of the three hyperelastic constitutive models that we tested, the Ogden model provided the best fits to both shear stress and normal stress. In conclusion, we developed a robust protocol to generate regularly-shaped, homogeneous thrombus mimics that lend themselves to simple shear testing under large deformation. Future studies will extend our model to include the effect of maturation and explore its fracture properties toward a better understanding of embolization.

bioengineering

Toward understanding thrombus fracture: Dissipative phenomena of whole blood clots

When thrombus fractures and breaks off it can occlude vital vessels such as those of the heart, lung, or brain. These thromboembolic conditions are responsible for 1 in 4 deaths world-wide. This problem is also of significant current interest as 1 in 3 COVID-19 intensive care patients exhibit thromboembolic complications. Thrombus resistance to fracture is driven by its intrinsic fracture toughness as well as other, non-surface-creating dissipative mechanisms. In our current work, we identify and quantify these latter mechanisms toward future studies that aim to delineate fracture from other forms of dissipation. To this end, we use an in vitro thrombus mimic system to produce whole blood clots and explore their dissipative mechanics under simple uniaxial extension, cyclic loading, and stress-relaxation. We found that whole blood clots exhibit Mullins effect, hysteresis, permanent set, strain-rate dependence, and nonlinear stress-relaxation. Interestingly, we found that performing these tests under dry or submerged conditions did not change our results. However, performing these tests under room temperature or body temperature conditions yielded differences. Overall, we have demonstrated that whole blood clots show several dissipative phenomena - similarly to hydrogels - that will be critical to our understanding of thrombus fracture.

bioengineering