bioRxiv Science⌕ Search

Biology subjects

Street, T. L.

Publications and source records attributed to Street, T. L..

6 recordsLinked to original sources

Addressing pandemic-wide systematic errors in the SARS-CoV-2 phylogeny

The SARS-CoV-2 genome occupies a unique place in infection biology - it is the most highly sequenced genome on earth (making up over 20% of public sequencing datasets) with fine scale information on sampling date and geography, and has been subject to unprecedented intense analysis. As a result, these phylogenetic data are an incredibly valuable resource for science and public health. However, the vast majority of the data was sequenced by tiling amplicons across the full genome, with amplicon schemes that changed over the pandemic as mutations in the viral genome interacted with primer binding sites. In combination with the disparate set of genome assembly workflows and lack of consistent quality control (QC) processes, the current genomes have many systematic errors that have evolved with the virus and amplicon schemes. These errors have significant impacts on the phylogeny, and therefore over the last few years, many thousands of hours of researchers time has been spent in "eyeballing" trees, looking for artefacts, and then patching the tree. Given the huge value of this dataset, we therefore set out to reprocess the complete set of public raw sequence data in a rigorous amplicon-aware manner, and build a cleaner phylogeny. Here we provide a global tree of 4,471,579 samples, built from a consistently assembled set of high quality consensus sequences from all available public data as of June 2024, viewable at https://viridian.taxonium.org. Each genome was constructed using a novel assembly tool called Viridian (https://github.com/iqbal-lab-org/viridian), developed specifically to process amplicon sequence data, eliminating artefactual errors and mask the genome at low quality positions. We provide simulation and empirical validation of the methodology, and quantify the improvement in the phylogeny. We hope the tree, consensus sequences and Viridian will be a valuable resource for researchers.

bioinformatics↗

Comparison of R9.4.1/Kit10 and R10/Kit12 Oxford Nanopore flowcells and chemistries in bacterial genome reconstruction

2.Complete, accurate, cost-effective, and high-throughput reconstruction of bacterial genomes for large-scale genomic epidemiological studies is currently only possible with hybrid assembly, combining long- (typically using nanopore sequencing) and short-read (Illumina) datasets. Being able to utilise nanopore-only data would be a significant advance. Oxford Nanopore Technologies (ONT) have recently released a new flowcell (R10.4) and chemistry (Kit12), which reportedly generate per-read accuracies rivalling those of Illumina data. To evaluate this, we sequenced DNA extracts from four commonly studied bacterial pathogens, namely Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa and Staphylococcus aureus, using Illumina and ONTs R9.4.1/Kit10, R10.3/Kit12, R10.4/Kit12 flowcells/chemistries. We compared raw read accuracy and assembly accuracy for each modality, considering the impact of different nanopore basecalling models, commonly used assemblers, sequencing depth, and the use of duplex versus simplex reads. "Super accuracy" (sup) basecalled R10.4 reads - in particular duplex reads - have high per-read accuracies and could be used to robustly reconstruct bacterial genomes without the use of Illumina data. However, the per-run yield of duplex reads generated in our hands with standard sequencing protocols was low (typically <10%), with substantial implications for cost and throughput if relying on nanopore data only to enable bacterial genome reconstruction. In addition, recovery of small plasmids with the best-performing long-read assembler (Flye) was inconsistent. R10.4/Kit12 combined with sup basecalling holds promise as a singular sequencing technology in the reconstruction of commonly studied bacterial genomes, but hybrid assembly (Illumina+R9.4.1 hac) currently remains the highest throughput, most robust, and cost-effective approach to fully reconstruct these bacterial genomes. 3. Impact statementOur understanding of microbes has been greatly enhanced by the capacity to evaluate their genetic make-up using a technology known as whole genome sequencing. Sequencers represent microbial genomes as stretches of shorter sequence known as reads, which are then assembled using computational algorithms. Different types of sequencing approach have advantages and disadvantages with respect to the accuracy and length of the reads they generate; this in turn affects how reliably genomes can be assembled. Currently, to completely reconstruct bacterial genomes in a high-throughput and cost-effective manner, researchers tend to use two different types of sequencing data, namely Illumina (short-read) and nanopore (long-read) data. Illumina data are highly accurate; nanopore data are much longer, and this combination facilitates accurate and complete bacterial genomes in a so-called "hybrid assembly". However, new developments in nanopore sequencing have reportedly greatly improved the accuracy of nanopore data, hinting at the possibility of requiring only a single sequencing approach for bacterial genomics. Here we evaluate these improvements in nanopore sequencing in the reconstruction of four bacterial reference strains, where the true sequence is already known. We show that although these improvements are extremely promising, for high-throughput, low-cost complete reconstruction of bacterial genomes hybrid assembly currently remains the optimal approach. 4. Data summaryThe authors confirm all supporting data, code and protocols have been provided within the article, through supplementary data files, or in publicly accessible repositories. Nanopore fast5 and fastq data are available in the ENA under project accession: PRJEB51164. Assemblies have been made available at: https://figshare.com/articles/online_resource/q20_comparison_genome_assemblies/196838 67. Code and analysis outputs are available at: https://gitlab.com/ModernisingMedicalMicrobiology/assembly_comparison_analysis/-/tree/main (tagged version v0.5.5).

genomics↗

High precision Neisseria gonorrhoeae variant and antimicrobial resistance calling from metagenomic Nanopore sequencing

The rise of antimicrobial resistant Neisseria gonorrhoeae is a significant public health concern. Against this background, rapid culture-independent diagnostics may allow targeted treatment and prevent onward transmission. We have previously shown metagenomic sequencing of urine samples from men with urethral gonorrhoea can recover near-complete N. gonorrhoeae genomes. However, disentangling the N. gonorrhoeae genome from metagenomic samples and robustly identifying antimicrobial resistance determinants from error-prone Nanopore sequencing is a substantial bioinformatics challenge. Here we demonstrate an N. gonorrhoeae diagnostic workflow for analysis of metagenomic sequencing data obtained from clinical samples using R9.4.1 Nanopore sequencing. We compared results from simulated and clinical infections with data from known reference strains and Illumina sequencing of isolates cultured from the same patients. We evaluated three Nanopore variant callers and developed a random forest classifier to filter called SNPs. Clair was the most suitable variant caller after SNP filtering. A minimum depth of 20x reads was required to confidently identify resistant determinants over the entire genome. Our findings show that metagenomic Nanopore sequencing can provide reliable diagnostic information in N. gonorrhoeae infection.

microbiology↗

Optimizing DNA extraction methods for Nanopore sequencing of Neisseria gonorrhoeae direct from urine samples

BackgroundEmpirical gonorrhoea treatment at initial diagnosis reduces onward transmission. However, increasing resistance to multiple antibiotics may necessitate waiting for culture-based diagnostics to select an effective treatment. There is a need for same-day culture-free diagnostics that identify infection and detect antimicrobial resistance.\n\nMethodsWe investigated if Nanopore sequencing can detect sufficient N. gonorrhoeae DNA to reconstruct whole genomes directly from urine samples. We used N. gonorrhoeae spiked urine samples and samples from gonorrhoea infections to determine optimal DNA extraction methods that maximize the amount of N. gonorrhoeae DNA sequenced whilst minimizing contaminating host DNA.\n\nResultsIn simulated infections the Qiagen UCP Pathogen Mini kit provided the highest ratio N. gonorrhoeae to human DNA and the most consistent results. Depletion of human DNA with saponin increased N. gonorrhoeae yields in simulated infections, but decreased yields in clinical samples. In ten urine samples from men with symptomatic urethral gonorrhoea, [&ge;]87% coverage of an N. gonorrhoeae reference genome was achieved in all samples, with [&ge;]92% coverage breath at [&ge;]10-fold depth in 7 (70%) samples. In simulated infections if [&ge;]104 CFU/ml of N. gonorrhoeae was present, sequencing of the large majority of the genome was frequently achieved. N. gonorrhoeae could also be detected from urine in cobas PCR Media tubes and from urethral swabs, and in the presence of simulated Chlamydia co-infection.\n\nConclusionUsing Nanopore sequencing of urine samples from men with urethral gonorrhoea sufficient data can be obtained to reconstruct whole genomes in the majority of samples without the need for culture.

microbiology↗

Real-time analysis of nanopore-based metagenomic sequencing from orthopaedic device infection

Prosthetic joint infections are clinically difficult to diagnose and treat. Previously, we demonstrated metagenomic sequencing on an Illumina MiSeq replicates the findings of current gold standard microbiological diagnostic techniques. Nanopore sequencing offers advantages in speed of detection over MiSeq. Here, we compare direct-from-clinical-sample metagenomic Illumina sequencing with Nanopore sequencing, and report a real-time analytical pathway for Nanopore sequence data, designed for detecting bacterial composition of prosthetic joint infections.\n\nDNA was extracted from the sonication fluids of seven explanted orthopaedic devices, and additionally from two culture negative controls, and was sequenced on the Oxford Nanopore Technologies MinION platform. A specific analysis pipeline was assembled to overcome the challenges of identifying the true infecting pathogen, given high levels of host contamination and unavoidable background lab and kit contamination.\n\nThe majority of DNA classified (>90%) was host contamination and discarded. Using negative control filtering thresholds, the species identified corresponded with both routine microbiological diagnosis and MiSeq results. By analysing sequences in real time, causes of infection were robustly detected within minutes from initiation of sequencing.\n\nWe demonstrate initial proof of concept that metagenomic MinION sequencing can provide rapid, accurate diagnosis for prosthetic joint infections. We demonstrate a novel, scalable pipeline for real-time analysis of MinION sequence data. The high proportion of human DNA in extracts prevents full genome analysis from complete coverage, and methods to reduce this could increase genome depth and allow antimicrobial resistance profiling.

microbiology↗

Molecular diagnosis of orthopaedic device infection direct from sonication fluid by metagenomic sequencing

Culture of multiple periprosthetic tissue samples is the current gold-standard for microbiological diagnosis of prosthetic joint infections (PJI). Additional diagnostic information may be obtained through sonication fluid culture of explants. However, current techniques can have relatively low sensitivity, with prior antimicrobial therapy and infection by fastidious organisms influencing results. We assessed if metagenomic sequencing of complete bacterial DNA extracts obtained direct from sonication fluid can provide an alternative rapid and sensitive tool for diagnosis of PJI.\n\nWe compared metagenomic sequencing with standard aerobic and anaerobic culture in 97 sonication fluid samples from prosthetic joint and other orthopaedic device infections. Reads from Illumina MiSeq sequencing were taxonomically classified using Kraken. Using 50 samples (derivation set), we determined optimal thresholds for the number and proportion of bacterial reads required to identify an infection and validated our findings in 47 independent samples.\n\nCompared to sonication fluid culture, the species-level sensitivity of metagenomic sequencing was 61/69(88%,95%CI 77-94%) (derivation samples 35/38[92%,79-98%]; validation 26/31[84%,66-95%]), and genus-level sensitivity was 64/69(93%,84-98%). Species-level specificity, adjusting for plausible fastidious causes of infection, species found in concurrently obtained tissue samples, and prior antibiotics, was 85/97(88%,79-93%) (derivation 43/50[86%,73-94%], validation 42/47[89%,77-96%]). High levels of human DNA contamination were seen despite use of laboratory methods to remove it. Rigorous laboratory good practice was required to prevent bacterial DNA contamination.\n\nWe demonstrate metagenomic sequencing can provide accurate diagnostic information in PJI. Our findings combined with increasing availability of portable, random-access sequencing technology offers the potential to translate metagenomic sequencing into a rapid diagnostic tool in PJI.

microbiology↗