bioRxiv Science⌕ Search

Biology subjects

Strasser, B.

Publications and source records attributed to Strasser, B..

3 recordsLinked to original sources

Metabolic modelling and time-resolved mapping of glucose oxidative metabolism in rats brain by indirect deuterium detection with 1H-FID-MRSI at 9.4T

ObjectThe present study exploits newly developed dynamic indirect 1H-[2H]-FID-MRSI at 9.4T, combined with a dedicated metabolic model, to enable regional and quantitative characterization of glucose oxidative metabolism flux in the rat brain with minimal metabolic assumptions, by measuring both 2H-labelled Glx turnover and pool size along a controlled 2H-Glc infusion protocol. Materials and MethodsSeven rats underwent dynamic 2D 1H-FID-MRSI during a 2-hour infusion of [6,6-2H2] glucose. Consecutive 13-min acquisitions quantified Glx-C4 1H-signal decay, converted to 2H-Glx concentrations using baseline metabolite pool sizes. A three-pool kinetic model including 2H-label loss was fitted to regional turnover curves to estimate oxidative flux (Vgt) and pyruvate dilution (Kdil). Model performance and parameter robustness were finally assessed with Monte-Carlo simulations. ResultsIn vivo 2H-Glx turnover showed a saturated exponential rise ([~]60 min), with a labelling plateau higher in striatum (1.85 mol/g) than hippocampus (1.55 mol/g). Metabolic modelling provided region-specific oxidative fluxes: Vgt = 0.27 {+/-} 0.07 mol/g/min (hippocampus) and Vgt = 0.40 {+/-} 0.06 mol/g/min (striatum), with consistent Kdil across regions. Simulations confirmed a good model robustness in retrieving Vgt over a large range of experimental conditions. DiscussionThis work shows the appropriateness of indirect dynamic 1H-[2H]-FID-MRSI for quantitative metabolic flux mapping of cerebral glucose oxidative metabolism.

neuroscience↗

21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)

A 3D density-weighted concentric ring trajectory (CRT) MRSI sequence is implemented for cardiac 31P-MRS at 7T. The point-by-point k-space sampling of traditional phase-encoded CSI sequences severely restricts the minimum scan time at higher spatial resolutions. Our proposed CRT sequence implements a stack of concentric rings trajectory, with a variable number of rings and planes spaced to optimise the density of k-space weighting. This creates flexibility in acquisition time, allowing acquisitions substantially faster than traditional phase-encoded CSI sequences, while retaining high SNR. We first characterise the signal-to-noise ratio and point spread function of the CRT sequence in phantoms. We then evaluate it at five different acquisition times and spatial resolutions in the hearts of five healthy participants at 7T. These different sequence durations are compared with existing published 3D acquisition-weighted CSI sequences with matched acquisition times and spatial resolutions. To minimise the effect of noise on the short acquisitions, low-rank denoising of the spatio-temporal data was also performed after acquisition. The proposed sequence measures 3D localised PCr/ATP ratios of the human myocardium in 2.5 minutes, 2.6 times faster than the minimum scan time for the acquisition-weighted phase-encoded CSI. Alternatively, in the same scan time a 1.7-times smaller nominal voxel volume can be achieved. Low-rank denoising reduced the variance of measured PCr/ATP ratios by 11% across all protocols. The faster acquisitions permitted by 7T CRT 31P-MRSI could make cardiac stress protocols or creatine kinase rate measurements (which involve repeated scans) more tolerable for patients without sacrificing spatial resolution.

physiology↗

Achieving High-Resolution Whole-Brain Slab 1H-MRSI with Compressed-Sensing and Low-Rank Reconstruction at 7 Tesla

Low sensitivity MR techniques such as magnetic resonance spectroscopic imaging (MRSI) greatly benefit from the gain in signal-to-noise (SNR) provided by ultra-high field MR. High-resolution and whole-brain slab MRSI remains however very challenging due to lengthy acquisition, low signal, lipid contamination and field inhomogeneity. In this study, we propose an acquisition-reconstruction scheme that combines a 1H-FID-MRSI sequence with compressed sensing acceleration and low-rank modeling with total-generalized-variation constraint to achieve metabolite imaging in two and three dimensions at 7 Tesla. The resulting images and volumes reveal highly detailed distributions that are specific to each metabolite and follow the underlying brain anatomy. The MRSI method was validated in a high-resolution phantom containing fine metabolite structures, and in 3 healthy volunteers. This new application of compressed sensing acceleration paves the way for high-resolution MRSI in clinical setting with acquisition times of 5 min for 2D MRSI at 2.5 mm and of 20 min for 3D MRSI at 3.3 mm isotropic.

neuroscience↗