bioRxiv Science⌕ Search

Biology subjects

Stöcker, Y.

Publications and source records attributed to Stöcker, Y..

2 recordsLinked to original sources

Fibrosis burden and spatial pattern affect left atrial appendage stasis in multi-beat multi-physics simulations

Purpose: Atrial fibrosis is associated with thromboembolic risk in atrial fibrillation, but how fibrosis-related contractile impairment alters blood transport in the left atrium (LA) and left atrial appendage (LAA) remains unclear. Prior multi-physics simulations coupled electromechanical (EM) and computational fluid dynamics (CFD) models to show that fibrosis impairs LA function and flow, but were limited to booster-only contraction and could not separate the effects of fibrosis burden from its spatial distribution. Here we examined how fibrosis burden and spatial pattern independently relate to long-term LA and LAA hemodynamics in full-cycle, multi-beat simulations on a common LA anatomy. Methods: Three fibrosis patterns derived from late gadolinium enhancement MRI were considered: one from the patient providing the common anatomy and two from additional patients, with the latter mapped onto the common anatomy via universal atrial coordinates. All three patterns were applied globally at matched burdens of 15.6% and 31.2%, yielding six global-fibrosis cases and a non-fibrotic reference. Two patterns were also confined to the LAA at three local burdens (10%, 25%, and 50%), yielding six LAA-fibrosis cases. A 3D EM model for the LA anatomy was coupled to a 0D circulatory model, so that the simulations resolved the reservoir, conduit, and booster phases. Full-cycle EM-derived wall motion drove subsequent multi-beat CFD simulations. Region-specific emptying fraction (EF), non-dimensional kinetic energy (KE), and the 90th percentile of blood residence time (TR) were evaluated for the LA and LAA. Results: Left ventricular stroke volume remained nearly constant across cases, while increasing global fibrosis burden progressively reduced LA and LAA EF (LA: 36% to 30-31%; LAA: 44% to 28-38%) and monotonically increased LA TR across all patterns. Non-dimensional LA KE showed an approximately quadratic association with LA EF across patterns, whereas LAA KE was more scattered but still increased with LAA EF. In contrast, the relationship between the 90th percentile of LAA TR and LAA EF showed pattern-specific, non-monotonic trends. Conclusions: Fibrosis burden and spatial distribution jointly shape LA and LAA hemodynamics, but through different mechanisms. LAA EF is a robust functional descriptor of chamber-averaged kinetic energy regardless of fibrosis pattern, whereas LAA blood stasis depends additionally on the spatial distribution of fibrosis beyond what bulk emptying fraction predicts. These findings support incorporating imaging-derived fibrosis pattern, and not only burden, alongside functional metrics when assessing thrombogenic risk in the LAA.

bioengineering↗

Effect of Wall Motion Sampling on CFD-Derived Left Atrial Flow Metrics

The temporal resolution of medical imaging sequences used to drive patient-specific computational fluid dynamics (CFD) simulations remains limited, typically providing 10-20 frames per cardiac cycle. Therefore, temporal interpolation to reconstruct left atrial (LA) wall motion and boundary conditions is required, but its impact on hemodynamic predictions has not been systematically characterized. To investigate this, we constructed high-temporal-resolution reference wall-motion data using electromechanical (EM) simulations on five patient-specific atrial geometries with a history of atrial fibrillation. We then generated temporally downsampled datasets to emulate clinical frame rates (5, 10, 20, and 40 frames per cycle) and performed CFD simulations to isolate the effects of temporal undersampling on hemodynamic metrics. The focus was placed on kinetic energy, KE, and residence time, TR, particularly in the left atrial appendage (LAA), where thrombosis is most likely to occur. We employed an immersed boundary method to prescribe the wall motion and computed blood TR through a passive scalar transport equation. Results indicate that while global LA hemodynamic indices were marginally affected by the frame rate (errors < 9%), LAA metrics were more sensitive with errors up to 31% compared to reference values. The results based on 20 and 40 frames per cycle yielded favorable agreement with reference results, while 5-and 10-frame reconstructions showed larger, though not systematically biased, deviations from the reference. Importantly, patient ranking by blood-stasis indices was largely preserved. The analysis suggests that patientspecific LA reconstructions derived from dynamic CT imaging provide a reliable basis for estimating LAA blood-stasis indices. Higher frame rates ([&ge;] 20 per cycle) offer improved quantitative accuracy, while lower temporal resolutions may remain informative for patient stratification purposes, where relative ranking is more relevant than absolute accuracy.

bioengineering↗