bioRxiv Science⌕ Search

Biology subjects

Stadlmeier, M.

Publications and source records attributed to Stadlmeier, M..

5 recordsLinked to original sources

Expanding Targeted Instrumentation for Discovery Applications: Complement Reporter Ion Quantification with a Quadrupole-Ion Trap Instrument

Proteomics workflows have traditionally been divided into discovery-based and targeted approaches, with instrumentation optimized specifically for each. Discovery experiments typically utilize high-resolution analyzers while targeted workflows rely on the sensitivity and specificity of triple quadrupole systems. Recently, a quadrupole-ion trap instrument (Stellar MS) demonstrated superior performance for targeted applications compared to conventional triple quadrupoles. In this study, we expand the capabilities of this platform to multiplexed shotgun proteomics using complement reporter ion quantification in an ion trap (iTMTproC). Benchmarking experiments with defined standards show that iTMTproC achieves quantification accuracy and interference reduction comparable to MultiNotch MS3 on the Orbitrap Fusion Lumos, a dedicated quadrupole-ion trap-Orbitrap tribrid instrument optimized for this purpose. Notably, iTMTproC quantifies slightly more proteins than MultiNotch MS3. We further validate this approach through a developmental time-series analysis of frog embryos, obtaining proteomic data nearly indistinguishable from MultiNotch MS3, with slightly increased protein quantification depth. These findings significantly extend the functionality of targeted instrumentation, underscoring the versatility of quadrupole-ion trap systems and providing cost-effective access to highly accurate, multiplexed quantitative shotgun proteomics.

systems biology↗

Global Protein-Turnover Quantification in Escherichia coli Reveals Cytoplasmic Recycling under Nitrogen-Limitation

Protein turnover is critical for proteostasis, but turnover quantification is challenging, and even in well-studied E. coli, proteome-wide measurements remain scarce. Here, we quantify the degradation rates of [~]3.2k E. coli proteins under 12 conditions by combining heavy isotope labeling with complement reporter ion quantification and find that cytoplasmic proteins are recycled when nitrogen is limited. We use knockout experiments to assign substrates to the known cytoplasmic ATP-dependent proteases. Surprisingly, none of these proteases are responsible for the observed cytoplasmic protein degradation in nitrogen limitation, suggesting that a major proteolysis pathway in E. coli remains to be discovered. Lastly, we show that protein degradation rates are generally independent of cell division rates. Thus, we introduce broadly applicable technology for protein turnover measurements and provide a rich resource for protein half-lives and protease substrates in E. coli, complementary to genomics data, that will allow researchers to decipher the control of proteostasis.

systems biology↗

Super-resolution mass spectrometry enables rapid, accurate, and highly-multiplexed proteomics at the MS2-level

In tandem mass spectrometry (MS2)-based multiplexed quantitative proteomics, the complement reporter ion approaches (TMTc and TMTproC) were developed to eliminate the ratio-compression problem of conventional MS2 level approaches. Resolving all high m/z complement reporter ions ([~]6.32 mDa spaced) requires mass resolution and scan speeds above the performance levels of Orbitrap instruments. Therefore, complement reporter ion quantification with TMT/TMTpro reagents is currently limited to 5 out of 11 (TMT) or 9 out of 18 (TMTpro) channels ([~]1 Da spaced). We first demonstrate that a Fusion Lumos Orbitrap can resolve 6.32 mDa spaced complement reporter ions with standard acquisition modes extended with 3-second transients. We then implemented a super-resolution mass spectrometry approach using the least-squares fitting (LSF) method for processing Orbitrap transients to achieve shotgun proteomics-compatible scan rates. The LSF performance resolves the 6.32 mDa doublets for all TMTproC channels in the standard mass range with transients as short as [~]108 ms (Orbitrap resolution setting of 50 000 at m/z 200). However, we observe a slight decrease in measurement precision compared to 1 Da spacing with the 108 ms transients. With 256 ms transients (resolution of 120 000 at m/z 200), coefficients of variation are essentially indistinguishable from 1 Da samples. We thus demonstrate the feasibility of highly-multiplexed, accurate, and precise shotgun-proteomics at the MS2 level.

systems biology↗

Differential nuclear import sets the timing of protein access to the embryonic genome

The development of a fertilized egg to an embryo requires the proper temporal control of gene expression1-6. During cell differentiation, timing is often controlled via cascades of transcription factors (TFs)7,8. However, in early development, transcription is often inactive, and many TF levels are constant, suggesting that unknown mechanisms govern the observed rapid and ordered onset of gene expression9. Here, we find that in early embryonic development, access of maternally deposited nuclear proteins to the genome is temporally ordered via importin affinities, thereby timing the expression of downstream targets. We quantify changes in the nuclear proteome during early development and find that nuclear proteins, such as TFs and RNA polymerases, enter nuclei sequentially. Moreover, we find that the timing of the access of nuclear proteins to the genome corresponds to the timing of downstream gene activation. We show that the affinity of proteins to importin is a major determinant in the timing of protein entry into embryonic nuclei. Thus, we propose a mechanism by which embryos encode the timing of gene expression in early development via biochemical affinities. This process could be critical for embryos to organize themselves before deploying the regulatory cascades that control cell identities. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=196 HEIGHT=200 SRC="FIGDIR/small/464816v1_ufig1.gif" ALT="Figure 1"> View larger version (85K): org.highwire.dtl.DTLVardef@1e9438org.highwire.dtl.DTLVardef@1950f92org.highwire.dtl.DTLVardef@131716corg.highwire.dtl.DTLVardef@10d6d24_HPS_FORMAT_FIGEXP M_FIG C_FIG

developmental biology↗

TMTPro Complementary Ion Quantification Increases Plexing and Sensitivity for Accurate Multiplexed Proteomics at the MS2 Level

Multiplexed proteomics is a powerful tool to assay cell states in health and disease, but accurate quantification of relative protein changes is impaired by interference from co-isolated peptides. Interference can be reduced by using MS3-based quantification, but this reduces sensitivity and requires specialized instrumentation. An alternative approach is quantification by complementary ions, which allows accurate and precise multiplexed quantification at the MS2 level and is compatible with the most widely distributed instruments. However, complementary ions of the popular TMT tag form inefficiently and multiplexing is limited to five channels. Here, we evaluate and optimize complementary ion quantification for the recently released TMTPro tag, which increases plexing capacity to eight channels (TMTProC). We find that the beneficial fragmentation properties of TMTPro increase quantification signal five-fold compared to TMT. This increased sensitivity results in ~65% more proteins quantified compared to TMTPro-MS3 and even slightly outperforms TMTPro-MS2. Furthermore, TMTProC quantification is more accurate than TMTPro-MS2 and even superior to TMTPro-MS3. To demonstrate the power of TMTProC, we analyzed a human and yeast interference sample and were able to quantify 13,290 proteins in 24 fractions. Thus, TMTProC advances multiplexed proteomics data quality and widens access to accurate multiplexed proteomics beyond laboratories with MS3-capable instrumentation.

systems biology↗