bioRxiv Science⌕ Search

Biology subjects

Sriram, S.

Publications and source records attributed to Sriram, S..

2 recordsLinked to original sources

Influence of preprocessing, distortion correction and cardiac triggering on the quality of diffusion MR images of spinal cord

Diffusion MRI of the spinal cord (SC) is susceptible to geometric distortion caused by field inhomogeneities, and prone to misalignment across time series and signal dropout caused by biological motion. Several modifications of image acquisition and image processing techniques have been introduced to overcome these artifacts, but their specific benefits are largely unproven and warrant further investigations. We aim to evaluate two specific aspects of image acquisition and processing that address image quality in diffusion studies of the spinal cord: susceptibility corrections to reduce geometric distortions, and cardiac triggering to minimize motion artifacts. First, we evaluate 4 distortion preprocessing strategies on 7 datasets of the cervical and lumbar SC and find that while distortion correction techniques increase geometric similarity to structural images, they are largely driven by the high-contrast cerebrospinal fluid, and do not consistently improve the geometry within the cord nor improve white-to-gray matter contrast. We recommend at a minimum to perform bulk-motion correction in preprocessing and posit that improvements/adaptations are needed for spinal cord distortion preprocessing algorithms, which are currently optimized and designed for brain imaging. Second, we design experiments to evaluate the impact of removing cardiac triggering. We show that when triggering is foregone, images are qualitatively similar to triggered sequences, do not have increased prevalence of artifacts, and result in similar diffusion tensor indices with similar reproducibility to triggered acquisitions. When triggering is removed, much shorter acquisitions are possible, which are also qualitatively and quantitatively similar to triggered sequences. We suggest that removing cardiac triggering for cervical SC diffusion can be a reasonable option to save time with minimal sacrifice to image quality.

neuroscience↗

On the Interaction of Biopotential Sensing and Right Leg Drive System with Electro-Quasistatic Human Body Communication

Continuous long-term sensing of biopotential signals is vital to facilitate accurate diagnosis. The current state of the art in wearable health monitoring relies on radiative technology for communication. Due to their radiative nature, these systems result in lossy and inefficient transmission, limiting the devices life span. Human Body Communication has emerged as an energy-efficient secure communication modality, and literature has shown body communication to transmit biopotential signals at 100x lower power than traditional radiative technologies. Unlike radiative communication that uses airwaves, HBC, specifically Capacitive Electro-Quasistatic HBC (EQS-HBC), couple signals and confine them within the human body. In Capacitive EQS-HBC, the transmitter uses an electrode to modulate the body potential to transmit data. The modulation of body potential by HBC raises the following concerns. Will HBC transmissions affect the quality of biopotential signals sensed from the body? Additionally, since biopotential sensing systems commonly use Right Leg Drive (RLD) to bias body potential, there is also a concern if RLD can affect the quality of HBC transmissions. For the first time, our work studies the interactions between EQS-HBC and biopotential sensing. Our work is important since understanding HBC-RLD interactions is integral to developing EQS-HBC-based biosensors for Body Area Networks (BANs). For the studies, we conducted lab experiments and developed circuit theoretic models to back the experimental outcomes. We show that due to their higher frequency content and common-mode nature, HBC transmissions do not affect the differential sensing of low-frequency biopotential signals. We show that biopotential sensing using RLD affects HBC. RLD deteriorates the signal strength of HBC transmissions. We thus propose not to use RLD with HBC. We demonstrate our proposed solution by transmitting ECG signals using HBC with 96% correlation compared to the traditional wireless system at a fraction of the power.

bioengineering↗