bioRxiv Science⌕ Search

Biology subjects

Sperry, Z. J.

Publications and source records attributed to Sperry, Z. J..

3 recordsLinked to original sources

High-density Neural Recordings from Feline Sacral Dorsal Root Ganglia with Thin-film Array

Objective: Dorsal root ganglia (DRG) are promising sites for recording sensory activity. Current technologies for DRG recording are stiff and typically do not have sufficient site density for high-fidelity neural data techniques. Approach: In acute experiments, we demonstrate single-unit neural recordings in sacral DRG of anesthetized felines using a 4.5 m-thick, high-density flexible polyimide microelectrode array with 60 sites and 30-40 m site spacing. We delivered arrays into DRG with ultrananocrystalline diamond shuttles designed for high stiffness affording a smaller footprint. We recorded neural activity during sensory activation, including cutaneous brushing and bladder filling, as well as during electrical stimulation of the pudendal nerve and anal sphincter. We used specialized neural signal analysis software to sort densely packed neural signals. Main results: We successfully delivered arrays in five of six experiments and recorded single-unit sensory activity in four experiments. The median neural signal amplitude was 55 V peak-to-peak and the maximum unique units recorded at one array position was 260, with 157 driven by sensory or electrical stimulation. In one experiment, we used the neural analysis software to track eight sorted single units as the array was retracted ~500 m. Significance: This study is the first demonstration of ultrathin, flexible, high-density electronics delivered into DRG, with capabilities for recording and tracking sensory information that are a significant improvement over conventional DRG interfaces.

bioengineering↗

Closed-loop sacral neuromodulation for bladder function using dorsal root ganglia sensory feedback in an acute feline model

Overactive bladder patients suffer from a frequent, uncontrollable urge to urinate, which can lead to a poor quality of life. We aim to improve open-loop sacral neuromodulation therapy by developing a conditional stimulation paradigm using neural recordings from dorsal root ganglia (DRG) as sensory feedback. Experiments were performed in 5 anesthetized felines. We implemented a Kalman filter-based algorithm to estimate the bladder pressure in real-time using sacral-level DRG neural recordings and initiated sacral root electrical stimulation when the algorithm detected an increase in bladder pressure. Closed-loop neuromodulation was performed during continuous cystometry and compared to bladder fills with continuous and no stimulation. Overall, closed-loop stimulation increased bladder capacity by 13.8% over no stimulation (p < 0.001) and reduced stimulation time versus continuous stimulation by 57.7%. High-confidence bladder single units had a reduced sensitivity during stimulation, with lower linear trendline fits and higher pressure thresholds for firing observed during stimulation trials. This study demonstrates the utility of decoding bladder pressure from neural activity for closed-loop control of sacral neuromodulation. An underlying mechanism for sacral neuromodulation may be a reduction in bladder sensory neuron activity during stimulation. Real-time validation during behavioral studies is necessary prior to clinical translation of closed-loop sacral neuromodulation.

bioengineering↗

Novel diamond shuttle to deliver flexible bioelectronics with reduced tissue compression

The ability to deliver flexible biosensors through the toughest membranes of the central and peripheral nervous system is an important challenge in neuroscience and neural engineering. Bioelectronic devices implanted through dura mater and thick epineurium would ideally create minimal compression and acute damage as they reach the neurons of interest. We demonstrate that a three-dimensional diamond shuttle can be easily made with a vertical support to deliver ultra-compliant polymer microelectrodes (4.5 m thick) in-vivo through dura mater and thick epineurium. The diamond shuttle has 54% less cross-sectional area than an equivalently stiff silicon shuttle, which we simulated will result in a 37% reduction in blood vessel damage. We also discovered that higher frequency oscillation of the shuttle (200 Hz) significantly reduced tissue compression regardless of the insertion speed, while slow speeds also independently reduced tissue compression. Insertion and recording performance are demonstrated in rat and feline models, but the large design space of these tools are suitable for research in a variety of animal models and nervous system targets.

bioengineering↗