bioRxiv Science⌕ Search

Biology subjects

Seymour, J. P.

Publications and source records attributed to Seymour, J. P..

11 recordsLinked to original sources

Biophysical modeling reveals how recording geometry shapes representations of cortical activity

Extracellular electrophysiological recordings reflect both the organization of neural activity and the geometry through which that activity is sampled. Here, we used biophysical modeling and experimental recordings from the macaque auditory cortex to determine how cortical activity is transformed across neural sources, extracellular signals, and recording geometries. In a biophysically detailed thalamocortical model, four separately instantiated cortical-column conditions spanning graded thalamic recruitment exhibited a graded response hierarchy across local field potential, current-source density, and multiunit activity, despite signal-dependent differences in the contributions of cortical neuronal populations. We then arranged independently simulated cortical columns into controlled spatial configurations and sampled the same underlying sources using virtual linear laminar and Directional and Scalable (DiSc) electrode arrays. The linear geometry primarily represented variation along cortical depth, whereas DiSc additionally represented circumferential variation associated with lateral source organization, demonstrating that recording geometry determines which spatial dimensions of common underlying activity are represented in extracellular measurements. Experimental recordings obtained with the corresponding geometries were consistent with these model-derived predictions: broadband-noise responses exhibited spatial organization shared across tone-evoked responses in both multidimensional DiSc maps and laminar profiles, despite substantial variation in frequency-dependent response magnitude across penetrations. Together, these results show that extracellular measurements represent an interaction between biological source organization and recording geometry. Biophysical forward modeling therefore provides a framework for determining which features of underlying circuit organization remain identifiable after extracellular sampling and for relating neural-interface design to the dimensions of cortical activity accessible experimentally.

neuroscience↗

Microelectrode arrays enable directional stereo-EEG during kainate-mediated seizures

Surgical planning for drug-resistant epilepsy often relies on stereo-EEG (sEEG) recordings obtained with cylindrical ring electrodes. Prior modeling studies, including lead-field analysis, suggest that microelectrodes distributed around an sEEG-sized insulating body offer superior source amplification and directional sensitivity that are not available with either a ring design or microelectrodes on micro-structures, e.g. Neuropixel. However, these advantages have not been demonstrated in seizure models. This study evaluated high-density sEEG recordings using directional microelectrode arrays in a kainate-mediated rat model (n=6). Two 64-channel microelectrode arrays were implanted near the hippocampus, and the signals were spatially averaged to emulate virtual ring electrodes for comparison. Device locations were reconstructed and placed in copies of the Waxholm Space Rat Brain Atlas registered to subject-specific MRI scans. In subjects exhibiting seizures (n=4), automated line length detection showed that microelectrode signals identified epileptiform activity sooner and with greater specificity than ring electrodes. In subjects that only seized post-kainate injection (n=3), manual review by a board-certified epileptologist confirmed that microelectrodes provided the earliest onset detection times. Furthermore, the microelectrode arrays high resolution revealed distinct instances of hyperactivity occurring at similar depths but from different directions -- a feature indistinguishable to standard ring electrodes. These results demonstrate that microelectrodes on a large insulating body significantly enhance signal quality and spatial localization. This technology offers a potential advancement over current clinical standards for identifying seizure foci during surgical planning. SIGNIFICANCESurgical treatment for drug-resistant epilepsy depends on accurately identifying the brain regions where seizures begin. Current stereo-EEG electrodes sample activity with ring contacts that average signals around the probe shaft, potentially obscuring directional differences in nearby neural activity. This study shows that microelectrodes distributed around an sEEG-sized insulating body can improve seizure-related signal detection and spatial localization compared with ring-like recordings from the same implant locations. By resolving activity that conventional ring electrodes cannot distinguish, high-density directional sEEG may provide more informative recordings for seizure mapping. These findings support the development of next-generation intracranial electrodes for improving epilepsy surgical planning.

neuroscience↗

Optimizing electrode placement and information capacity for local field potentials in cortex

Recent neurosurgery advancements include improved stereotactic targeting and increased density and specificity of electrophysiological evaluation. This study introduces a subject-specific, in silico modeling tool for optimizing electrode placement and maximizing coverage with a variety of devices. The basis for optimization is the Shannon-Hartley information capacity of field potentials derived from dipolar sources. The approach integrates subject-specific MRI data with finite element modeling (FEM) used to simulate the sensitivity of subdural and intracortical devices. Sensitivity maps, or lead fields, from these models enable the comparison of different electrode placements, contact sizes, contact configurations, and substrate properties, which are often overlooked factors. One key tool is a genetic algorithm that optimizes electrode placement by maximizing information capacity. Another is a sparse sensor method, Sparse Electrode Placement for Input Optimization (SEPIO), that selects the best sensor subsets for accurate source classification. We demonstrate several use cases for clinicians, engineers, and researchers. Overall, these open-source tools provide a quantitative framework to select devices from a neurosurgical armament and to optimize device and contact placement. Using these tools may help refine electrode coverage with low channel count devices while minimizing the burden of invasive surgery. The study demonstrates that optimized electrode placement significantly improves the information capacity and signal quality of local field potential (LFP) recordings. The tools developed offer a valuable approach for refining neurosurgical techniques and enhancing the design of neural implants. HighlightsO_LItool for simulating subject-specific local field potentials and electrode sensitivity. C_LIO_LIptimized electrode placement enhances ROI source coverage, and signal quality. C_LIO_LIsensor-based classification boosts data quality without extra electrode cost. C_LIO_LIcomparisons of devices and contact arrangements. C_LI Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=78 SRC="FIGDIR/small/650658v3_ufig1.gif" ALT="Figure 1"> View larger version (36K): org.highwire.dtl.DTLVardef@1a3a7aaorg.highwire.dtl.DTLVardef@154a776org.highwire.dtl.DTLVardef@be4826org.highwire.dtl.DTLVardef@72caa9_HPS_FORMAT_FIGEXP M_FIG C_FIG

neuroscience↗

Ultra-flexible and Stretchable Intrafascicular Peripheral Nerve Recording Device with Axon-dimension, Cuff-less Microneedle Electrode Array

Peripheral nerve mapping tools with higher spatial resolution are needed to advance systems neuroscience, and potentially provide a closed-loop biomarker in neuromodulation applications. Two critical challenges of microscale neural interfaces are (i) how to apply them to small peripheral nerves, and (ii) how to minimize chronic reactivity. We developed a flexible microneedle nerve array (MINA), which is the first high-density penetrating electrode array made with axon-sized silicon microneedles embedded in low-modulus thin silicone. We present the design, fabrication, acute recording, and chronic reactivity to an implanted MINA. Distinctive units were identified in the rat peroneal nerve. We also demonstrate a long-term, cuff-free, and suture-free fixation manner using rose bengal as a light-activated adhesive for two timepoints. The tissue response at 1-week included a sham (N=5) and MINA-implanted (N=5) group, and the response at 6-week also included a sham (N=3) and MINA-implanted (N=4) group. These conditions were quantified in the left vagus nerve of rats using histomorphometry. Micro-CT was added to visualize and quantify tissue encapsulation around the implant. MINA demonstrated a reduction in encapsulation thickness over previously quantified interfascicular methods. Future challenges include techniques for precise insertion of the microneedle electrodes and demonstrating long-term recording.

neuroscience↗

Sharpened and mechanically robust carbon fiber electrode arrays for neural interfacing

Bioelectric medicine treatments target disorders of the nervous system unresponsive to pharmacological methods. While current stimulation paradigms effectively treat many disorders, the underlying mechanisms are relatively unknown, and current neuroscience recording electrodes are often limited in their specificity to gross averages across many neurons or axons. Here, we develop a novel, durable carbon fiber electrode array adaptable to many neural structures for precise neural recording. Carbon fibers were sharpened using a reproducible blowtorch method that uses the reflection of fibers against the surface of a water bath. The arrays were developed by partially embedding carbon fibers in medical-grade silicone to improve durability. We recorded acute spontaneous electrophysiology from the rat cervical vagus nerve (CVN), feline dorsal root ganglia (DRG), and rat brain. Blowtorching resulted in fibers of 72.3 {+/-} 33.5 degree tip angle with 146.8 {+/-} 17.7 m exposed carbon. Silicone-embedded carbon fiber arrays were durable with 87.5% of fibers remaining after 50,000 passes. Observable neural clusters were recorded using sharpened carbon fiber electrodes from rat CVN (41.8 Vpp), feline DRG (101.1 Vpp), and rat brain (80.7 Vpp). Recordings from the feline DRG included physiologically-relevant signals from increased bladder pressure and cutaneous brushing. These results suggest that this carbon fiber array is a uniquely durable and adaptable neural recording device. In the future, this device may be useful as a bioelectric medicine tool for diagnosis and closed-loop neural control of therapeutic treatments and monitoring systems.

bioengineering↗

High-density Neural Recordings from Feline Sacral Dorsal Root Ganglia with Thin-film Array

Objective: Dorsal root ganglia (DRG) are promising sites for recording sensory activity. Current technologies for DRG recording are stiff and typically do not have sufficient site density for high-fidelity neural data techniques. Approach: In acute experiments, we demonstrate single-unit neural recordings in sacral DRG of anesthetized felines using a 4.5 m-thick, high-density flexible polyimide microelectrode array with 60 sites and 30-40 m site spacing. We delivered arrays into DRG with ultrananocrystalline diamond shuttles designed for high stiffness affording a smaller footprint. We recorded neural activity during sensory activation, including cutaneous brushing and bladder filling, as well as during electrical stimulation of the pudendal nerve and anal sphincter. We used specialized neural signal analysis software to sort densely packed neural signals. Main results: We successfully delivered arrays in five of six experiments and recorded single-unit sensory activity in four experiments. The median neural signal amplitude was 55 V peak-to-peak and the maximum unique units recorded at one array position was 260, with 157 driven by sensory or electrical stimulation. In one experiment, we used the neural analysis software to track eight sorted single units as the array was retracted ~500 m. Significance: This study is the first demonstration of ultrathin, flexible, high-density electronics delivered into DRG, with capabilities for recording and tracking sensory information that are a significant improvement over conventional DRG interfaces.

bioengineering↗

Multi-channel intraneural vagus nerve recordings with a novel high-density carbon fiber microelectrode array

Autonomic nerves convey essential neural signals that regulate vital body functions. Recording clearly distinctive physiological neural signals from autonomic nerves will help develop new treatments for restoring regulatory functions. However, this is very challenging due to the small nature of autonomic nerves and the low-amplitude signals from their small axons. We developed a multi-channel, high-density, intraneural carbon fiber microelectrode array (CFMA) with ultra-small electrodes (8-9 m in diameter, 150-250 m in length) for recording physiological action potentials from small autonomic nerves. In this study, we inserted CFMA with up to 16 recording carbon fibers in the cervical vagus nerve of 22 isoflurane-anesthetized rats. We recorded action potentials with peak-to-peak amplitudes of 15.1-91.7 V and signal-to-noise ratios of 2.0-8.3 on multiple carbon fibers per experiment, determined conduction velocities of some vagal signals in the afferent (0.7-4.4 m/sec) and efferent (0.7-8.8 m/sec) directions, and monitored firing rate changes in breathing and blood glucose modulated conditions. Overall, these experiments demonstrated that CFMA is a novel interface for in-vivo intraneural action potential recordings. This work is considerable progress towards the comprehensive understanding of physiological neural signaling in vital regulatory functions controlled by autonomic nerves.

bioengineering↗

Stimulation-artifact-free, high-spatiotemporal-resolution in vivo optoEphys with μLED optoelectrodes

The combination of in vivo extracellular recording and genetic-engineering-assisted optical stimulation is a powerful tool for the study of neuronal circuits. Precise analysis of complex neural circuits requires high-density integration of multiple cellular-size light sources and recording electrodes. However, high-density integration inevitably introduces stimulation artifact. We present minimal-stimulation-artifact (miniSTAR) {micro}LED optoelectrodes that enable effective elimination of stimulation artifact. A multi-metal-layer structure with a shielding layer effectively suppresses capacitive coupling of stimulation signals. A heavily-boron-doped silicon substrate silences the photovoltaic effect induced from LED illumination. With transient stimulation pulse shaping, we reduced stimulation artifact on miniSTAR {micro}LED optoelectrodes to below 50 {micro}Vpp, much smaller than a typical spike detection threshold, at optical stimulation of > 50 mW mm-2 irradiance. We demonstrated high-temporal resolution (< 1 ms) opto-electrophysiology without any artifact-induced signal quality degradation during in vivo experiments. MiniSTAR {micro}LED optoelectrodes will facilitate functional mapping of local circuits and discoveries in the brain.

bioengineering↗

Ultra-compliant carbon nanotube stretchable direct bladder interface

The bladder, stomach, intestines, heart, and lungs all move dynamically to achieve their purpose. A long-term implantable device that can attach onto an organ, sense its movement, and deliver current to modify the organ function would be useful in many therapeutic applications. The bladder, for example, is a smooth muscle organ that can suffer from incomplete contractions that result in urinary retention with patients requiring using catheterization. Those affected may benefit from a combination of strain sensor and electrical stimulator to better control bladder emptying. We describe the materials and design of such a device made from thin layer carbon nanotube (CNT) and Ecoflex 00-50 and demonstrate its function with in vivo feline bladders. During bench-top characterization, the resistive and capacitive sensors exhibited reliable output throughout 5,000 stretching cycles under physiology condition. In vivo measurement with piezoresistive device showed a high correlation between sensor resistance and volume. Stimulation driven from Pt-PDMS composite electrodes successfully induced bladder contraction. We present method for reliable connection and packaging of medical grade wire to the CNT device. This work is an important step toward the translation of low-durometer elastomers, stretchable CNT percolation and Pt-PDMS composite, which are ideal for large strain bioelectric applications to sense or modulate dynamic organ states.

bioengineering↗

Novel diamond shuttle to deliver flexible bioelectronics with reduced tissue compression

The ability to deliver flexible biosensors through the toughest membranes of the central and peripheral nervous system is an important challenge in neuroscience and neural engineering. Bioelectronic devices implanted through dura mater and thick epineurium would ideally create minimal compression and acute damage as they reach the neurons of interest. We demonstrate that a three-dimensional diamond shuttle can be easily made with a vertical support to deliver ultra-compliant polymer microelectrodes (4.5 m thick) in-vivo through dura mater and thick epineurium. The diamond shuttle has 54% less cross-sectional area than an equivalently stiff silicon shuttle, which we simulated will result in a 37% reduction in blood vessel damage. We also discovered that higher frequency oscillation of the shuttle (200 Hz) significantly reduced tissue compression regardless of the insertion speed, while slow speeds also independently reduced tissue compression. Insertion and recording performance are demonstrated in rat and feline models, but the large design space of these tools are suitable for research in a variety of animal models and nervous system targets.

bioengineering↗