bioRxiv Science⌕ Search

Biology subjects

Sesay, A. M.

Publications and source records attributed to Sesay, A. M..

2 recordsLinked to original sources

Mucus production, host-microbiome interactions, hormone sensitivity, and innate immune responses modeled in human endo- and ecto-cervix chips

Modulation of mucus production by the human endo- and ecto-cervical epithelium by steroid hormones and associated interactions with commensal microbiome play a central role in the physiology and pathophysiology of the female reproductive tract. However, most of our knowledge about these interactions is based on results from animal studies or in vitro models that fail to faithfully mimic the mucosal environment of the human cervix. Here we describe microfluidic organ-on-a-chip (Organ Chip) models of the human cervical mucosa that recreate the cervical epithelial-stromal interface with a functional epithelial barrier and produce abundant mucus that has compositional, biophysical, and hormone-responsive properties similar to the living cervix. Application of continuous fluid flow to chips lined with primary human cervical epithelial cells from a commercial source that contained a mixture of primary human ecto- and endo-cervical epithelial cells promoted preferential expression of the ecto-cervical phenotype, whereas use of periodic flow including periods of stasis induced endo-cervical specialization. When the periodic flow Cervix Chips were co-cultured with living Lactobacillus crispatus and Gardnerella vaginalis bacterial communities to respectively mimic the effects of human host interactions with optimal (healthy) or non-optimal (dysbiotic) microbiome associated with an ascending infection in the female reproductive tract, significant differences in tissue innate immune responses, barrier function, cell viability and protein profile, and mucus composition were detected reminiscent of those observed in vivo. Thus, these Organ Chip models of human cervix provide a physiologically relevant experimental in vitro model to study cervical mucus physiology and its role in human host-microbiome interactions as well as a potential preclinical testbed for development of therapeutic interventions to enhance womens health.

bioengineering↗

Establishment of physiologically relevant oxygen gradients in microfluidic organ chips

In vitro models of human organs must accurately reconstitute oxygen concentrations and gradients that are observed in vivo to mimic gene expression, metabolism, and host-microbiome interactions. Here we describe a simple strategy to achieve physiologically relevant oxygen tension in a two-channel human small intestine-on-a-chip (Intestine Chip) lined with primary human duodenal epithelium and intestinal microvascular endothelium in parallel channels separated by a porous membrane while both channels are perfused with oxygenated medium. This strategy was developed using computer simulations that predicted lowering the oxygen permeability of poly-dimethlysiloxane (PDMS) chips in specified locations using a gas impermeable film will allow the cells to naturally decrease the oxygen concentration through aerobic respiration and reach steady-state oxygen levels < 36 mm Hg (< 5%) within the epithelial lumen. The approach was experimentally confirmed using chips with embedded oxygen sensors that maintained this stable oxygen gradient. Furthermore, Intestine Chips cultured with this approach supported formation of a villus epithelium interfaced with a continuous endothelium and maintained intestinal barrier integrity for 72 h. This strategy recapitulates in vivo functionality in an efficient, inexpensive, and scalable format that improves the robustness and translatability of Organ Chip technology for studies on microbiome as well as oxygen sensitivity.

bioengineering↗