bioRxiv Science⌕ Search

Biology subjects

Schroeder, L. K.

Publications and source records attributed to Schroeder, L. K..

7 recordsLinked to original sources

Genital herpes shedding episodes associate with alterations in the spatial organization and activation of mucosal immune cells

Herpes Simplex Virus 2 (HSV-2) infection results in variable rates of local viral shedding in anogenital skin. The impact of episodic viral exposures on immune cells in adjacent mucosal tissues, including the genital tract, is unknown. However, any immune responses at this site could impact protective mucosal immunity, tissue homeostasis, and adverse health outcomes. To investigate the impact of HSV-2 on cervicovaginal tract immunity, we applied flow cytometry, immunofluorescent imaging, analysis of soluble immune factors, and spatial transcriptomics to cervicovaginal tissue and blood samples provided by a total of 232 HSV-2 seropositive and seronegative participants, with genital HSV-2 shedding evaluated at the time of biopsy. This unique dataset was used to define and spatially map immune cell subsets and localized gene expression via spatial transcriptomics. HSV-2 seropositivity alone was associated with minimal differences in cervicovaginal and circulating T cell phenotypes. However, the vaginal mucosa during active HSV-2 shedding was associated with alterations in T cell, macrophage, and dendritic cell localization and gene expression consistent with increased immune surveillance, with immune activating and suppressing signals potentially reinforcing mucosal tissue homeostasis. SummaryIn context of episodic HSV-2 shedding, immune cells mobilize and co-localize in the vaginal epithelium, expressing cytotoxic and inflammatory genes and immunoregulatory genes that collectively may promote tissue homeostasis in settings of episodic viral shedding to limit damage.

immunology↗

Implementation of an adaptive-optics assisted isoSTED nanoscope

The highest level of three-dimensional (3D) resolution in stimulated emission depletion (STED) nanoscopy involves harnessing a 4Pi architecture using two opposing objectives. This protocol describes the construction and alignment of a 4Pi-STED nanoscope, commonly referred to as an isoSTED nanoscope. It guides interested researchers through assembling optomechanical components, configuring electronic and control devices, aligning the optical beam path, and assessing the instruments performance. Designed for adept optical instrument builders, this protocol offers a detailed roadmap for constructing an isoSTED nanoscope with adaptive optics (AO) in approximately 12 months. With this finely calibrated instrument, researchers can achieve 3D biological images with isotropic sub-50-nm resolution in thick samples up to 35 {micro}m in depth.

bioengineering↗

Bacterial vaginosis-driven changes in vaginal T cell phenotypes and their implications for HIV susceptibility

Bacterial vaginosis (BV) is a dysbiosis of the vaginal microbiome that is prevalent among reproductive-age females worldwide. Adverse health outcomes associated with BV include an increased risk of sexually-acquired HIV, yet the immunological mechanisms underlying this association are not well understood. To investigate BV-driven changes to cervicovaginal tract (CVT) and circulating T cell phenotypes, participants with or without BV provided vaginal tract (VT) and ectocervical (CX) tissue biopsies and PBMC samples. High-parameter flow cytometry revealed an increased frequency of cervical conventional CD4+ T cells (Tconv) expressing CCR5. However, we found no difference in number of CD3+CD4+CCR5+ cells in the CX or VT of BV+ vs BV- individuals, suggesting that BV-driven increased HIV susceptibility may not be solely attributed to increased CVT HIV target cell abundance. Flow cytometry also revealed that individuals with BV have an increased frequency of dysfunctional CX and VT CD39+ Tconv and CX tissue-resident CD69+CD103+ Tconv, reported to be implicated in HIV acquisition risk and replication. Many soluble immune factor differences in the CVT further support that BV elicits diverse and complex CVT immune alterations. Our comprehensive analysis expands on potential immunological mechanisms that may underlie the adverse health outcomes associated with BV including increased HIV susceptibility.

immunology↗

3D Adaptive Optical Nanoscopy for Thick Specimen Imaging at sub-50 nm Resolution

Understanding cellular organization demands the best possible spatial resolution in all three dimensions (3D). In fluorescence microscopy, this is achieved by 4Pi nanoscopy methods that combine the concepts of using two opposing objectives for optimal diffraction-limited 3D resolution with switching fluorescent molecules between bright and dark states to break the diffraction limit. However, optical aberrations have limited these nanoscopes to thin samples and prevented their application in thick specimens. Here, we have developed a nanoscope that, by utilizing an advanced adaptive optics strategy, achieves sub-50 nm isotropic resolution of structures such as neuronal synapses and ring canals previously inaccessible in tissue.

biophysics↗

Nanoscale subcellular architecture revealed by multicolor 3D salvaged fluorescence imaging

Combining the molecular specificity of fluorescent probes with three-dimensional (3D) imaging at nanoscale resolution is critical for investigating the spatial organization and interactions of cellular organelles and protein complexes. We present a super-resolution light microscope that enables simultaneous multicolor imaging of whole mammalian cells at ~20 nm 3D resolution. We show its power for cell biology research with fluorescence images that resolved the highly convoluted Golgi apparatus and the close contacts between the endoplasmic reticulum and the plasma membrane, structures that have traditionally been the imaging realm of electron microscopy.\n\nOne Sentence SummaryComplex cellular structures previously only resolved by electron microscopy can now be imaged in multiple colors by 4Pi-SMS.

biophysics↗

Nano-scale size holes in ER sheets provide an alternative to tubules for highly-curved membranes

The endoplasmic reticulum (ER) is composed of interconnected membrane sheets and tubules. Super-resolution microscopy recently revealed densely packed, rapidly moving ER tubules, highlighting the importance of revisiting classical views of ER structure with high spatial resolution in living cells. Using live-cell Stimulated Emission Depletion (STED) microscopy, we show highly dynamic, subdiffraction-sized holes in ER sheets. Holes coexist with uniform sheet regions and are distinct from tubular ER structures. The curvature-stabilizing reticulon protein Rtn4 localizes to these holes and the ER luminal tether Climp63 controls their diameter and mobility. Analytical modeling demonstrates that holes in ER sheets can serve as reservoirs for curvature-stabilizing proteins to support ER tubule extension and retraction, thus providing an explanation for how the ER locally alters its morphology on fast time-scales.\n\nOne Sentence SummaryDynamic nano-scale sized holes are prominent features of ER sheets that serve as reservoirs for curvature-stabilizing proteins to support ER tubule extension and retraction.

cell biology↗

Simultaneously measuring image features and resolution in live-cell STED images

Reliable interpretation and quantification of cellular features in fluorescence microscopy requires an accurate estimate of microscope resolution. This is typically obtained by measuring the image of a non-biological proxy for a point-like object, such as a fluorescent bead. While appropriate for confocal microscopy, bead-based measurements are problematic for Stimulated Emission Depletion (STED) and similar techniques where the resolution depends critically on the choice of fluorophore and acquisition parameters. We demonstrate that for a known geometry, e.g. tubules, the resolution can be accurately measured by fitting a model that accounts for both the Point Spread Function (PSF) and the fluorophore distribution. To address the problem of coupling between tubule diameter and PSF width, we developed a technique, Nested-loop Ensemble PSF (NEP) fitting. NEP fitting enables extraction of the size of cellular features and the PSF in fixed-cell and live-cell images without relying on beads or pre-calibration. We validate our technique using fixed microtubules and apply it to measure the diameter of endoplasmic reticulum tubules in live COS-7 cells. NEP fitting has been implemented as a plugin for the PYthon Microscopy Environment (PYME), a freely available and open source software.

cell biology↗