bioRxiv Science⌕ Search

Biology subjects

Scholz, A.

Publications and source records attributed to Scholz, A..

13 recordsLinked to original sources

Physical activity modulates early visual response and improves target detection in humans

Brain state changes affect visual perception by altering spatial resolution. Attention enhances the spatial resolution decorrelating neuronal activity in early nonhuman primate (NHP) visual cortex. Physical activity (PA) amplifies these attentional effects in rodents but impact of PA on visual perception in humans remains uncertain. We investigated the relationship between broadband high-frequency activity (BHA: 80-150 Hz) recorded with magnetoencephalography (MEG) and visual detection performance. We found that PA enhanced visual target detection predicted by a reduction of early BHA responses (<90 msec). This effect may be due to reduced interneuronal correlation to improve spatial resolution. Moreover, PA improved spatial integration time, as indicated by a linear relationship between reaction times and BHA variation with target eccentricity. These findings provide evidence that PA influences neuronal activity critical for early visual perception, optimizing visual processing at the initial stages of the visual hierarchy.

neuroscience↗

Physical Exercise Improves Working Memory through Ripple-Spindle Coupling

Spindle-ripple coupling enhances memory consolidation during sleep. Ripples, representing the compressed reactivation of environmental information, provide a mechanism for retaining memory information in chronological order and are also crucial for working memory (WM) during wakefulness. Brief sessions of physical exercise (PE) are proposed to boost WM. In concurrent EEG/MEG sessions, we investigated the role of PE in WM performance and high-frequency-ripple to spindle coupling. Ripples, identified in MEG sensors covering the medial temporal lobe (MTL) region, predicted individual WM performance. Ripples were locked to robust oscillatory patterns in the EEG defined spindle band. Spindle activity and ripples decrease during initial stimulus presentation and rebound after 1 sec. Behaviorally, PE enhanced WM performance. Neurophysiologically, PE scaled the ripple rate with the number of items to be kept in WM and strengthened the coupling between ripple events and spindle oscillations. These findings reveal that PE enhances WM by coordinating ripple-spindle interaction.

neuroscience↗

The ABC transporter MsbA in a dozen environments

High-resolution structure determination of membrane proteins typically requires isolation from the native lipid bilayer and reconstitution into artificial membrane mimics. For this purpose, numerous detergents, amphipols, polymers and membrane scaffold proteins are available. The choice of the specific membrane substitute can strongly affect the proteins specific activity, stability and conformational spectrum, potentially leading to errors or misinterpretation during analysis. The bacterial ATP-binding cassette transporter MsbA is a prominent example of such environment-specific bias, resulting in apparent conformational and activity responses. Here, we present a systematic analysis of the conformational spectrum of MsbA, stabilized in a dozen environments, using cryo-EM. Our data show pronounced structural feedback of the ABC transporter to the respective membrane mimetics. Detergents generally favour a conformation with wide separation of the nucleotide-binding domains, while nanodiscs induce the narrow conformation. Notably, only three of the dozen tested environments allow MsbA to sample the functional conformational spectrum, enabling full movement of the nucleotide-binding domains between narrow and wide inward-facing conformations. We expect this study to serve as a blueprint for other membrane proteins, even where the structural reaction to the hydrophobic environment is not directly visible but still critical for the proteins function.

molecular biology↗

Nanobodies as novel tools to monitor the mitochondrial fission factor Drp1

In cells, mitochondria undergo constant fusion and fission. An essential factor for fission is the mammalian dynamin-related protein 1 (Drp1). Dysregulation of Drp1 has been linked to neurodegenerative diseases including Parkinsons as well as cardiovascular diseases and cancer. Here, we developed nanobodies (Nbs) for proteomics, advanced microscopy and live cell imaging of Drp1. To specifically enrich endogenous Drp1 with interacting proteins for proteomics, we functionalized high-affinity Nbs as capture matrices. Furthermore, we detected Drp1 by bivalent Nbs combined with site-directed fluorophore labelling in super-resolution STORM microscopy. For real-time imaging of Drp1, we intracellularly expressed fluorescently labelled Nbs, so-called chromobodies (Cbs). To improve the signal-to-noise ratio, we further converted Cbs into a "turnover-accelerated" format. With these imaging probes, we visualized the dynamics of endogenous Drp1 upon compound-induced mitochondrial fission in living cells. Considering the wide range of research applications, the presented Nb toolset will open up new possibilities for advanced functional studies of Drp1 in disease-relevant models.

cell biology↗

A high-resolution map of functional miR-181 response elements in the thymus reveals the role of coding sequence targeting and an alternative seed match

MicroRNAs (miRNAs) are critical post-transcriptional regulators in many biological processes. They act by guiding RNA-induced silencing complexes to miRNA response elements (MREs) in target mRNAs, inducing translational inhibition and/or mRNA degradation. Functional MREs are expected to predominantly occur in the 3 untranslated region and involve perfect base-pairing of the miRNA seed. Here, we generate a high-resolution map of miR-181a/b-1 (miR-181) MREs to define the targeting rules of miR-181 in developing murine T-cells. By combining a multi-omics approach with computational high-resolution analyses, we uncover novel miR-181 targets and demonstrate that miR-181 acts predominantly through RNA destabilization. Importantly, we discover an alternative seed match and identify a distinct set of targets with repeat elements in the coding sequence which are targeted by miR-181 and mediate translational inhibition. In conclusion, deep profiling of MREs in primary cells is critical to expand physiologically relevant targetomes and establish context-dependent miRNA targeting rules. Key Points* Deep profiling identifies novel targets of miR-181 associated with global gene regulation. * miR-181 MREs in repeat elements in the coding sequence act through translational inhibition. * High-resolution analysis reveals an alternative seed match in functional MREs.

immunology↗

Eddy current-induced artifacts correction in high gradient strength diffusion MRI with dynamic field monitoring: demonstration in ex vivo human brain imaging

PurposeTo demonstrate the advantages of spatiotemporal magnetic field monitoring to correct eddy current-induced artifacts (ghosting and geometric distortions) in high gradient strength diffusion MRI (dMRI). MethodsA dynamic field camera with 16 NMR field probes was used to characterize eddy current fields induced from diffusion gradients for different gradients strengths (up to 300 mT/m), diffusion directions, and shots in a 3D multi-shot EPI sequence on a 3T Connectom scanner. The efficacy of dynamic field monitoring-based image reconstruction was demonstrated on high-resolution whole brain ex vivo dMRI. A 3D multi-shot image reconstruction framework was informed with the actual nonlinear phase evolution measured with the dynamic field camera, thereby accounting for high-order eddy currents fields on top of the image encoding gradients in the image formation model. ResultsEddy current fields from diffusion gradients at high gradient strength in a 3T Connectom scanner are highly nonlinear in space and time, inducing high-order spatial phase modulations between odd/even echoes and shots that are not static during the readout. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting approaches such as navigator- and structured low-rank-based methods or MUSE, followed by image-based distortion correction with eddy. Improved dMRI analysis is demonstrated with diffusion tensor imaging and high-angular resolution diffusion imaging. ConclusionStrong eddy current artifacts characteristic of high gradient strength dMRI can be well corrected with dynamic field monitoring-based image reconstruction, unlike the two-step approach consisting of ghosting correction followed by geometric distortion reduction with eddy.

bioengineering↗

A nanobody-based toolset to monitor and modify the mitochondrial GTPase Miro1

The mitochondrial outer membrane (MOM)-anchored GTPase Miro1, is a central player in mitochondrial transport and homeostasis. The dysregulation of Miro1 in amyotrophic lateral sclerosis (ALS) and Parkinsons disease (PD) suggests that Miro1 may be a potential biomarker or drug target in neuronal disorders. However, the molecular functionality of Miro1 under (patho-) physiological conditions is poorly known. For a more comprehensive understanding of the molecular functions of Miro1, we have developed Miro1-specific nanobodies (Nbs) as novel research tools. We identified seven Nbs that bind either the N- or C-terminal GTPase domain of Miro1 and demonstrate their application as research tools for proteomic and imaging approaches. To visualize the dynamics of Miro1 in real time, we selected intracellularly functional Nbs, which we reformatted into chromobodies (Cbs) for time- lapse imaging of Miro1. By genetic fusion to an Fbox domain, these Nbs were further converted into Miro1-specific degrons and applied for targeted degradation of Miro1 in live cells. In summary, this study presents a collection of novel Nbs that serve as a toolkit for advanced biochemical and intracellular studies and modulations of Miro1, thereby contributing to the understanding of the functional role of Miro1 in disease-derived model systems.

cell biology↗

High-fidelity, high-spatial-resolution diffusion MRI of the ex-vivo whole human brain on the 3T Connectom scanner using structured low-rank EPI ghost correction

Diffusion MRI (dMRI) of whole, intact, fixed postmortem human brain at high spatial resolution serves as key bridging technology for 3D mapping of structural connectivity and tissue microstructure at the mesoscopic scale. Ex vivo dMRI offers superior spatial resolution compared to in vivo dMRI but comes with its own technical challenges due to the significantly reduced T2 relaxation times and decreased diffusivity incurred by tissue fixation. The altered physical properties of fixed tissue necessitate the use of alternative acquisition strategies to preserve SNR and achieve sufficient diffusion weighting. Multi-shot or segmented 3D echo planar imaging (EPI) sequences have been used to shorten echo times (TEs) with reduced distortions from field inhomogeneity and eddy currents on small-bore MR scanners and have been adopted for high b-value dMRI of ex vivo whole human brain specimens. The advent of stronger gradients on human MRI scanners has led to improved image quality and a wider range of diffusion-encoding parameters for dMRI but at the cost of more severe eddy currents that result in spatial and temporal variations in the background magnetic field, which cannot be corrected for using standard vendor-provided ghost correction solutions. In this work, we show that conventional ghost correction techniques based on navigators and linear phase correction may be insufficient for EPI sequences using strong diffusion-sensitizing gradients in ex vivo dMRI experiments, resulting in orientationally biased dMRI estimates. This previously unreported problem is a critical roadblock in any effort to leverage scanners with ultra-high gradients for high-precision mapping of human neuroanatomy at the mesoscopic scale. We propose an advanced reconstruction method based on structured low-rank matrix modeling that reduces the ghosting substantially. We show that this method leads to more accurate and reliable dMRI metrics, as exemplified by diffusion tensor imaging and high angular diffusion imaging analyses in distributed neuroanatomical areas of fixed whole human brain specimens. Our findings advocate for the use of advanced reconstruction techniques for recovering unbiased metrics from ex vivo dMRI acquisitions and represent a crucial step toward making full use of strong diffusion-encoding gradients for neuroscientific studies seeking to study brain structure at multiple spatial scales.

neuroscience↗

Single-domain antibodies for targeting, detection and in vivo imaging of human CD4+ cells

The advancement of new immunotherapies necessitates appropriate probes to monitor the presence and distribution of distinct immune cell populations. Considering the key role of CD4+ T cells in regulating immunological processes, we generated novel single-domain antibodies (nanobodies, Nbs) that specifically recognize human CD4. After in depth analysis of their binding properties, recognized epitopes, and effects on T cell proliferation, activation and cytokine release, we selected CD4 Nbs that did not interfere with crucial T cell processes in vitro and converted them into immune tracers for non-invasive molecular imaging. By optical imaging, we demonstrate the ability of a high-affinity CD4-Nb to specifically visualize CD4+ cells in vivo using a xenograft model. Furthermore, time-resolved immune positron emission tomography (immunoPET) of a human CD4 knock-in mouse model showed rapid accumulation of 64Cu-radiolabeled CD4-Nb in CD4+ T cell-rich tissues. We propose that the CD4 Nbs presented here could serve as versatile probes for stratifying patients and monitoring individual immune responses during personalized immunotherapy in both cancer and inflammatory diseases.

immunology↗

A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of Human ex vivo Brain Imaging on the 3T Connectome Scanner

In vivo diffusion-weighted magnetic resonance imaging is limited in signal-to-noise-ratio (SNR) and acquisition time, which constrains spatial resolution to the macroscale regime. Ex vivo imaging, which allows for arbitrarily long scan times, is critical for exploring human brain structure in the mesoscale regime without loss of SNR. Standard head array coils designed for patients are sub-optimal for imaging ex vivo whole brain specimens. The goal of this work was to design and construct a 48-channel ex vivo whole brain array coil for high-resolution and high b-value diffusion-weighted imaging on a 3T Connectome scanner. The coil was validated with bench measurements and characterized by imaging metrics on an agar brain phantom and an ex vivo human brain sample. The two-segment coil former was constructed for a close fit to a whole human brain, with small receive elements distributed over the entire brain. Imaging tests including SNR and G-factor maps were compared to a 64-channel head coil designed for in vivo use. There was a 2.9-fold increase in SNR in the peripheral cortex and a 1.3-fold gain in the center when compared to the 64-ch head coil. The 48-channel ex vivo whole brain coil also decreases noise amplification in highly parallel imaging, allowing acceleration factors of approximately one unit higher for a given noise amplification level. The acquired diffusion-weighted images in a whole ex vivo brain specimen demonstrate the applicability of the developed coil for high-resolution and high b-value diffusion-weighted ex vivo brain MRI studies.

bioengineering↗

NeutrobodyPlex - Nanobodies to monitor a SARS-CoV-2 neutralizing immune response

As the COVID-19 pandemic escalates, the need for effective vaccination programs, therapeutic intervention, and diagnostic tools increases. Here, we identified 11 unique nanobodies (Nbs) specific for the SARS-CoV-2 spike receptor-binding domain (RBD) of which 8 Nbs potently inhibit the interaction of RBD with angiotensin-converting enzyme 2 (ACE2) as the major viral docking site. Following a detailed epitope determination and characterization of the binding mode by structural analysis, we constructed a hetero-bivalent Nb targeting two different epitopes within the RBD:ACE2 interface. This resulted in a high-affinity binder with a viral neutralization efficacy in the picomolar range. Using the bivalent Nb as a surrogate, we established a competitive multiplex binding assay ("NeutrobodyPlex") for detailed analysis of the presence and performance of neutralizing RBD-binding antibodies in the serum of convalescent or vaccinated patients. As demonstrated, the NeutrobodyPlex enables high-throughput screening and detailed analysis of neutralizing immune responses in infected or vaccinated individuals, helping to monitor immune status or guide vaccine design. This approach is easily transferrable to diagnostic laboratories worldwide.

immunology↗

uap: Reproducible and Robust HTS Data Analysis

BackgroundA lack of reproducibility has been repeatedly criticized in computational research. High throughput sequencing (HTS) data analysis is a complex multi-step process. For most of the steps a range of bioinformatic tools is available and for most tools manifold parameters need to be set. Due to this complexity, HTS data analysis is particularly prone to reproducibility and consistency issues. We have defined four criteria that in our opinion ensure a minimal degree of reproducible research for HTS data analysis. A series of workflow management systems is available for assisting complex multi-step data analyses. However, to the best of our knowledge, none of the currently available work flow management systems satisfies all four criteria for reproducible HTS analysis.\n\nResultsHere we present uap, a workflow management system dedicated to robust, consistent, and reproducible HTS data analysis. uap is optimized for the application to omics data, but can be easily extended to other complex analyses. It is available under the GNU GPL v3 license at https://github.com/yigbt/uap.\n\nConclusionsuap is a freely available tool that enables researchers to easily adhere to reproducible research principles for HTS data analyses.

bioinformatics↗

uORF-Tools - Workflow for the determination of translation-regulatory upstream open reading frames

Ribosome profiling (ribo-seq) provides a means to analyze active translation by determining ribosome occupancy in a transcriptome-wide manner. The vast majority of ribosome protected fragments resides within the protein-coding sequence of mRNAs. However, commonly reads are also found within the transcript leader sequence (TLS) (aka 5 untranslated region) preceding the main open reading frame (ORF), which indicates the translation of regulatory upstream ORFs (uORFs). Here, we present a workflow for the identification of functional uORFs, which contribute to the translational regulation of their associated main ORFs. The workflow is available as free and open Snakemake workflow. Furthermore, we provide a comprehensive human uORF annotation file, which can be used within the pipeline, thus reducing the runtime. (Availability: https://github.com/anibunny12/uORF-Tools)

bioinformatics↗