bioRxiv Science⌕ Search

Biology subjects

Scheiderer, L.

Publications and source records attributed to Scheiderer, L..

2 recordsLinked to original sources

Spontaneously blinking fluorophores for accelerated MINFLUX nanoscopy

Spontaneously blinking fluorophores, a class of molecules switching rapidly between a dark and a brightly emitting state, have emerged as a popular core to build fluorescent markers for super-resolution microscopy. With typical on-times in the order of tens of milliseconds, they are most suitable for STORM and related nanoscopy methods. Recent MINFLUX nanoscopy, however, can localize molecules even within a millisecond and achieve an up to ten times higher localization precision. Here, we present a series of spontaneous blinkers with short on-times (1-3 ms) matching MINFLUX recording time-scales. Our design builds upon a silicon rhodamine fluorescent core with a modified thiophene- or a benzothiophene-fused spirolactam fragment, which shifts the spirocyclization equilibrium toward the dark closed form at physiological conditions, imparting cell permeability. Concurrently, we obtain a highly photostable, short-lived open form with bright red emission. Characterizing the blinking behavior of single fluorophores bound to three different protein tags (antibodies, nanobodies, and HaloTag self-labeling enzyme) allowed us to select the best candidate for MINFLUX microscopy. The short on-times speed up MINFLUX localization by up to 30-fold.

biophysics↗

MINFLUX dissects the unimpeded walking of kinesin-1

We report on an interferometric MINFLUX microscope that records protein movements with down to 1.7 nm precision within less than 1 ms. While such spatio-temporal resolution has so far required linking a strongly scattering 30-500 nm diameter bead to the much smaller protein, MINFLUX localization requires the detection of only down to 20 photons from an ~1-nm sized fluorophore. Harnessing this resolution, we dissect the unhindered stepping of the motor protein kinesin-1 on microtubules at up to physiological ATP concentrations. By attaching the fluorophore to different kinesin-1 sites and resolving steps and substeps of these protein constructs, we uncover a three-dimensional orientation change of the unbound kinesin head. We also find that kinesin-1 takes up ATP while only one head is bound, whereas hydrolysis of ATP occurs with both heads bound to the microtubule, resolving a long-standing conundrum of its mechanochemical cycle. Our results establish MINFLUX as a non-invasive tool for tracking protein movements and probing submillisecond structural rearrangements with nanometer resolution.

biophysics↗