bioRxiv Science⌕ Search

Biology subjects

Radhakrishna, R.

Publications and source records attributed to Radhakrishna, R..

2 recordsLinked to original sources

Axonal spike-count regimes link spinal cord stimulation periodicity to artificial sensory detection and discrimination in rodents

Electrical stimulation is widely used to evoke artificial sensation, yet how temporal stimulation patterns are transformed into neural activity and perception remains poorly understood. Recent behavioral studies have shown that increasing the aperiodicity of spinal cord stimulation pulse trains alters both detection thresholds and discrimination performance despite constant pulse counts, suggesting a role for temporal structure beyond rate alone. However, the neural mechanisms underlying these effects remain unresolved. We developed a biophysically grounded computational framework linking a finite-element model of the rodent spinal cord, conductance-based axon simulations, and observer decision models to investigate how stimulation periodicity shapes neural responses and resulting behavior. By systematically varying stimulation amplitude, frequency, and inter-pulse interval variability, we identified distinct spike-count regimes arising from interactions between stimulation timing and axonal membrane dynamics. These regimes ranged from single spikes and small volleys to sustained spike trains, and they exhibited diverse frequency- and variability-dependent trends. No single regime was able to sufficiently explain experimentally observed detection threshold trends; instead, mixtures of regimes accurately reproduced both frequency-dependent threshold behavior and trial-level variability. Extending this framework to periodicity discrimination, we show that features derived from regime mixtures contain sufficient information to recover behavioral psychometric curves. Furthermore, observer model results provide a mechanistic account of behavioral asymmetries depending on the periodicity of the reference stimulus: discrimination relative to periodic inputs relied on combined rate and timing evidence, whereas discrimination relative to aperiodic inputs was dominated by timing irregularity. These results establish a mechanistic link between stimulation temporal structure, axonal spike generation, and perceptual behavior. This framework suggests that spinal cord stimulation does not operate within a single fixed neural regime but instead engages a spectrum of spike-count regimes whose mixtures shape perception. These findings have important implications for the design of biomimetic stimulation strategies, highlighting temporal patterning as a key dimension for controlling sensory outcomes.

neuroscience↗

Planar Amorphous Silicon Carbide Microelectrode Arrays for Chronic Recording in Rat Motor Cortex

Chronic implantation of intracortical microelectrode arrays (MEAs) capable of recording from individual neurons can be used for the development of brain-machine interfaces. However, these devices show reduced recording capabilities under chronic conditions due, at least in part, to the brains foreign body response. This creates a need for MEAs that can minimize the foreign body response to enable long-term recording. A potential approach to reduce the foreign body response is the use of ultrathin MEAs. Here, we fabricated ultrathin (cross-sectional area: 160 {micro}m2) amorphous silicon carbide (a-SiC) MEAs with sixteen electrode channels and implanted them into the motor cortex of seven female Sprague-Dawley rats. A-SiC was chosen as the fabrication base for its high chemical stability, good electrical insulation properties, and amenability to thin film fabrication techniques. Electrochemical analysis and neural recordings were performed weekly for 4 months. MEAs were characterized in vitro pre-implantation and in vivo using electrochemical impedance spectroscopy and cyclic voltammetry at 50 mV/s and 50,000 mV/s. Neural recordings were analyzed for single unit activity. At the end of the study, animals were sacrificed for immunohistochemistry analysis. We observed statistically significant, but small, increases in 1 and 30 kHz impedance values and 50,000 mV/s charge storage capacity over the 16-week implantation period. Slow sweep 50 mV/s CV and 1 Hz impedance did not significantly change over time. Impedance values increased from 11.6 M{Omega} to 13.5 M{Omega} at 1 Hz, 1.2 M{Omega} to 2.9 M{Omega} at 1 kHz, and 0.11 M{Omega} to 0.13 M{Omega} at 30 kHz over 16 weeks. The median charge storage capacity of the implanted electrodes at 50 mV/s were 58.1 mC/cm2 on week 1 and 55.9 mC/cm2 on week 16, and at 50,000 mV/s were 4.27 mC/cm2 on week 1 and 5.93 mC/cm2 on week 16. Devices were able to record neural activity from 92% of all active channels at the beginning of the study, At the study endpoint, a-SiC devices were still recording single-unit activity on 51% of electrochemically active electrode channels. In addition, we observed that the signal-to-noise ratio experienced a small decline of only -0.19 per week. We also classified the units as fast and slow spiking based on the trough-to-peak time. Although the overall presence of single units declined, fast and slow spiking units declined at a similar rate. Furthermore, immunohistochemistry showed minimal foreign body response to the a-SiC devices, as highlighted by statistically insignificant differences in activated glial cells between implanted brains slices and contralateral sham slices, as evidenced by GFAP staining. NeuN staining revealed the presence of neural cell bodies close to the implantation site, again statistically not different from a contralateral sham slice. These results support the use of ultrathin a-SiC MEAs for long-term implantation and use in brain-machine interfaces.

bioengineering↗