bioRxiv Science⌕ Search

Biology subjects

Rabut, C.

Publications and source records attributed to Rabut, C..

4 recordsLinked to original sources

Ultrasonic reporters of calcium for deep tissue imaging of cellular signals

Calcium imaging has enabled major biological discoveries. However, the scattering of light by tissue limits the use of standard fluorescent calcium indicators in living animals. To address this limitation, we introduce the first genetically encoded ultrasonic reporter of calcium (URoC). Based on a unique class of air-filled protein nanostructures called gas vesicles, we engineered URoC to produce elevated nonlinear ultrasound signal upon binding to calcium ions. With URoC expressed in mammalian cells, we demonstrate noninvasive ultrasound imaging of calcium signaling in vivo during drug-induced receptor activation. URoC brings the depth and resolution advantages of ultrasound to the in vivo imaging of dynamic cellular function and paves the way for acoustic biosensing of a broader variety of biological signals.

bioengineering↗

A window to the brain: ultrasound imaging of human neural activity through a permanent acoustic window

Recording human brain activity is crucial for understanding normal and aberrant brain function. However, available recording methods are either highly invasive or have relatively low sensitivity. Functional ultrasound imaging (fUSI) is an emerging technique that offers sensitive, large-scale, high-resolution neural imaging. However, fUSI cannot be performed through adult human skull. Here, we use a polymeric skull replacement material to create an acoustic window allowing ultrasound to monitor brain activity in fully intact adult humans. We design the window through experiments in phantoms and rodents, then implement it in a participant undergoing reconstructive skull surgery. Subsequently, we demonstrate fully non-invasive mapping and decoding of cortical responses to finger movement, marking the first instance of high-resolution (200 m) and large-scale (50 mmx38 mm) brain imaging through a permanent acoustic window.

neuroscience↗

Doppler Slicing for Ultrasound Super-Resolution Without Contrast Agents

Much of the information needed for diagnosis and treatment monitoring of diseases like cancer and cardiovascular disease is found at scales below the resolution limit of classic ultrasound imaging. Recently introduced vascular super-localization methods provide more than a ten-fold improvement in spatial resolution by precisely estimating the positions of microbubble contrast agents. However, most vascular ultrasound scans are currently performed without contrast agents due to the associated cost, training, and post-scan monitoring. Here we show that super-resolution ultrasound imaging of dense vascular structures can be achieved using the natural contrast of flowing blood cells. Instead of relying on separable targets, we used Fourier-based decomposition to separate signals arising from the different scales of vascular structures while removing speckle noise using multi-ensemble processing. This approach enabled the use of compressed sensing for super-resolution imaging of the underlying vascular structures, improving resolution by a factor of four. Reconstruction of ultrafast mouse brain scans revealed details that could not be resolved in regular Doppler images, agreeing closely with bubble-based super-localization microscopy of the same fields of view. By combining multi-ensemble Doppler acquisitions with narrowband Fourier decomposition and computational super-resolution imaging, this approach opens new opportunities for affordable and scalable super-resolution ultrasound imaging.

bioengineering↗

Ultrafast amplitude modulation for molecular and hemodynamic ultrasound imaging

Ultrasound is playing an emerging role in molecular and cellular imaging thanks to new micro- and nanoscale contrast agents and reporter genes. Acoustic methods for the selective in vivo detection of these imaging agents are needed to maximize their impact in biology and medicine. Existing ultrasound pulse sequences use the nonlinearity in contrast agents response to acoustic pressure to distinguish them from mostly linear tissue scattering. However, such pulse sequences typically scan the sample using focused transmissions, resulting in a limited frame rate and restricted field of view. Meanwhile, existing wide-field scanning techniques based on plane wave transmissions suffer from limited sensitivity or nonlinear artifacts. To overcome these limitations, we introduce an ultrafast nonlinear imaging modality combining amplitude-modulated pulses, multiplane wave transmissions and selective coherent compounding. This technique achieves contrast imaging sensitivity comparable to much slower gold-standard amplitude modulation sequences and enables the acquisition of larger and deeper fields of view, while providing a much faster imaging framerate of 3.2kHz. Additionally, it enables simultaneous nonlinear and linear image formation, and allows concurrent monitoring of phenomena accessible only at ultrafast framerates, such as blood volume variations. We demonstrate the performance of this ultrafast amplitude modulation (uAM) technique by imaging gas vesicles, an emerging class of genetically encodable biomolecular contrast agents, in several in vitro and in vivo contexts. These demonstrations include the rapid discrimination of moving contrast agents and the real-time monitoring of phagolysosomal function in the mouse liver.

bioengineering↗