bioRxiv Science⌕ Search

Biology subjects

Poser, B. A.

Publications and source records attributed to Poser, B. A..

6 recordsLinked to original sources

Novel insights into hippocampal perfusion using high-resolution, multi-modal 7T MRI

We present a comprehensive study on the non-invasive measurement of hippocampal perfusion. Using high-resolution 7 Tesla arterial spin labelling data, we generated robust perfusion maps and observed significant variations in perfusion among hippocampal subfields, with CA1 exhibiting the lowest perfusion levels. Notably, these perfusion differences were robust and detectable even within five minutes and just fifty perfusion-weighted images per subject. To understand the underlying factors, we examined the influence of image quality metrics, various tissue microstructure and morphometry properties, macrovasculature and cytoarchitecture. We observed higher perfusion in regions located closer to arteries, demonstrating the influence of vascular proximity on hippocampal perfusion. Moreover, ex vivo cytoarchitectonic features based on neuronal density differences appeared to correlate stronger with hippocampal perfusion than morphometric measures like gray matter thickness. These findings emphasize the interplay between microvasculature, macrovasculature, and metabolic demand in shaping hippocampal perfusion. Our study expands the current understanding of hippocampal physiology and its relevance to neurological disorders. By providing in vivo evidence of perfusion differences between hippocampal subfields, our findings have implications for diagnosis and potential therapeutic interventions. In conclusion, our study provides a valuable resource for extensively characterising hippocampal perfusion.

neuroscience↗

Evaluating the capabilities and challenges of layer-fMRI VASO at 3T

Sub-millimeter functional imaging has the potential to capture cortical layer-specific functional information flow within and across brain systems. Recent sequence advancements of fMRI signal readout and contrast generations resulted in wide adaptation of layer-fMRI protocols across the global ultra-high-field (UHF) neuroimaging community. However, most layer-fMRI applications are confined to one of {approx}100 privileged UHF imaging centers, and sequence contrasts with unwanted sensitivity to large draining veins. In this work, we propose the application of vein-signal free vascular space occupancy (VASO) layerfMRI sequences at widely accessible 3T scanners. Specifically, we implement, characterize, and apply a cerebral blood volume (CBV)-sensitive VASO fMRI at a 3T scanner setup, as it is typically used in the majority of cognitive neuroscience and clinical neuroscience fMRI studies. We find that the longer [Formula], and stronger relative T1 contrast at 3T can account for some of the lower z-magnetization in the inversion-recovery VASO sequence compared to 7T and 9.4T. In the main series of experiments (N=16), we test the utility of this setup for motor tasks and find that-while being limited by thermal noise-3T layer-fMRI VASO is feasible within conventional scan durations. In a series of auxiliary studies, we furthermore explore the generalizability of the developed layer-fMRI protocols for a larger range of study designs including: visual stimulation, whole brain movie watching paradigms, and cognitive tasks with weaker effect sizes. We hope that the developed imaging protocols will help to increase accessibility of vein-signal free layer-fMRI imaging tools to a wider community of neuroimaging centers. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=179 SRC="FIGDIR/small/501554v1_ufig1.gif" ALT="Figure 1"> View larger version (66K): org.highwire.dtl.DTLVardef@1b2c6b5org.highwire.dtl.DTLVardef@139b13org.highwire.dtl.DTLVardef@129ff82org.highwire.dtl.DTLVardef@45e9d8_HPS_FORMAT_FIGEXP M_FIG C_FIG

neuroscience↗

Mesoscopic Quantification of Cortical Architecture in the Living Human Brain

AO_SCPLOWBSTRACTC_SCPLOWMesoscopic (0.1-0.5 mm) interrogation of the living human brain is critical for advancing neuroscience and bridging the resolution gap with animal models. Despite the variety of MRI contrasts measured in recent years at the mesoscopic scale, in vivo quantitative imaging of T2* has not been performed. Here we provide a dataset containing empirical T2* measurements acquired at 0.35 x 0.35 x 0.35 mm3 voxel resolution using 7 Tesla MRI. To demonstrate unique features and high quality of this dataset, we generate flat map visualizations that reveal fine-scale cortical substructures such as layers and vessels, and we report quantitative depth-dependent T2* (as well as R2*) values in primary visual cortex and auditory cortex that are highly consistent across subjects. This dataset is freely available at https://doi.org/10.17605/OSF.IO/N5BJ7, and may prove useful for anatomical investigations of the human brain, as well as for improving our understanding of the basis of the T2* -weighted (f)MRI signal.

neuroscience↗

Sub-millimetre resolution laminar fMRI using Arterial Spin Labelling in humans at 7T

Laminar fMRI at ultra-high magnetic field strength is typically carried out using the Blood Oxygenation Level-Dependent (BOLD) contrast. Despite its unrivalled sensitivity to detecting activation, the BOLD contrast is limited in its spatial specificity due to signals stemming from intra-cortical ascending and pial veins. Alternatively, regional changes in perfusion (i.e., cerebral blood flow through tissue) are colocalised to neuronal activation, which can be non-invasively measured using arterial spin labelling (ASL) MRI. In addition, ASL provides a quantitative marker of neuronal activation in terms of perfusion signal, which is simultaneously acquired along with the BOLD signal. However, ASL for laminar imaging is challenging due to the lower SNR of the perfusion signal and higher RF power deposition i.e., specific absorption rate (SAR) of ASL sequences. In the present study, we present for the first time in humans, isotropic sub-millimetre spatial resolution functional perfusion images using Flow-sensitive Alternating Inversion Recovery (FAIR) ASL with a 3D-EPI readout at 7T. We show that robust statistical activation maps can be obtained with perfusion-weighting in a single session. We observed the characteristic BOLD amplitude increase towards the superficial laminae, and, in apparent discrepancy, the relative perfusion profile shows a decrease of the amplitude and the absolute perfusion profile a much smaller increase towards the cortical surface. Considering the draining vein effect on the BOLD signal using model-based spatial convolution, we show that the empirically measured perfusion and BOLD profiles are, in fact, consistent with each other. This study demonstrates that laminar perfusion fMRI in humans is feasible at 7T and that caution must be exercised when interpreting BOLD signal laminar profiles as direct representation of the cortical distribution of neuronal activity.

neuroscience↗

LAYNII: A software suite for layer-fMRI

High-resolution fMRI in the sub-millimeter regime allows researchers to resolve brain activity across cortical layers and columns non-invasively. While these high-resolution data make it possible to address novel questions of directional information flow within and across brain circuits, the corresponding data analyses are challenged by MRI artifacts, including image blurring, image distortions, low SNR, and restricted coverage. These challenges often result in insufficient spatial accuracy of conventional analysis pipelines. Here we introduce a new software suite that is specifically designed for layer-specific functional MRI: LayNii. This toolbox is a collection of command-line executable programs written in C/C++ and is distributed open-source and as pre-compiled binaries for Linux, Windows, and macOS. LayNii is designed for layer-fMRI data that suffer from SNR and coverage constraints and thus cannot be straightforwardly analyzed in alternative software packages. Some of the most popular programs of LayNii contain layerification and columnarization in the native voxel space of functional data as well as many other layer-fMRI specific analysis tasks: layer-specific smoothing, model-based vein mitigation of GE-BOLD data, quality assessment of artifact dominated sub-millimeter fMRI, as well as analyses of VASO data. HighlightsO_LIA new software toolbox is introduced for layer-specific functional MRI: LayNii. C_LIO_LILayNii is a suite of command-line executable C++ programs for Linux, Windows, and macOS. C_LIO_LILayNii is designed for layer-fMRI data that suffer from SNR and coverage constraints. C_LIO_LILayNii performs layerification in the native voxel space of functional data. C_LIO_LILayNii performs layer-smoothing, GE-BOLD deveining, QA, and VASO analysis. C_LI O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=78 SRC="FIGDIR/small/148080v3_ufig1.gif" ALT="Figure 1"> View larger version (19K): org.highwire.dtl.DTLVardef@e12e9org.highwire.dtl.DTLVardef@1fbb564org.highwire.dtl.DTLVardef@41da13org.highwire.dtl.DTLVardef@1545106_HPS_FORMAT_FIGEXP M_FIG Graphical abstract C_FIG

neuroscience↗

MESMERISED: Super-accelerated 7 T STEAM imaging for quantitative multi-contrast and diffusion MRI

There is an increasing interest in quantitative imaging of T1, T2 and diffusion contrast in the brain due to greater robustness against bias fields and artifacts, as well as better biophysical interpretability in terms of microstructure. However, acquisition time constraints are a challenge, particularly when multiple quantitative contrasts are desired and when extensive sampling of diffusion directions, high b-values or long diffusion times are needed for multi-compartment microstructure modeling. Although ultra-high fields of 7 T and above have desirable properties for many MR modalities, the shortening T2 and the high specific absorption rate (SAR) of inversion and refocusing pulses bring great challenges to quantitative T1, T2 and diffusion imaging. Here, we present the MESMERISED sequence (Multiplexed Echo Shifted Multiband Excited and Recalled Imaging of STEAM Encoded Diffusion). MESMERISED removes the dead time in Stimulated Echo Acquisition Mode (STEAM) imaging by an echo-shifting mechanism. The echo-shift (ES) factor is independent of multiband (MB) acceleration and allows for very high multiplicative (ESxMB) acceleration factors, particularly under moderate and long mixing times. This results in super-acceleration and high time efficiency at 7 T for quantitative T1 and diffusion imaging, while also retaining the capacity to perform quantitative T2 and B1 mapping. We demonstrate the super-acceleration of MESMERISED for whole-brain T1 relaxometry with total acceleration factors up to 36 at 1.8 mm isotropic resolution, and up to 54 at 1.25 mm resolution qT1 imaging, corresponding to a 6x and 9x speedup, respectively, compared to MB-only accelerated acquisitions. We then demonstrate highly efficient diffusion MRI with high b-values and long diffusion times in two separate cases. First, we show that super-accelerated multi-shell diffusion acquisitions with 370 whole-brain diffusion volumes over 8 b-value shells up to b = 7000 s/mm2 can be generated at 2 mm isotropic in under 8 minutes, a data rate of almost a volume per second, or at 1.8 mm isotropic in under 11 minutes, achieving up to 3.4x speedup compared to MB-only. A comparison of b = 7000 s/mm2 MESMERISED against standard MB pulsed gradient spin echo (PGSE) diffusion imaging shows 70% higher SNR efficiency and greater effectiveness in supporting complex diffusion signal modeling. Second, we demonstrate time-efficient sampling of different diffusion times with 1.8 mm isotropic diffusion data acquired at four diffusion times up to 290 ms, which supports both Diffusion Tensor Imaging (DTI) and Diffusion Kurtosis Imaging (DKI) at each diffusion time. Finally, we demonstrate how adding quantitative T2 and B1+ mapping to super-accelerated qT1 and diffusion imaging enables efficient quantitative multi-contrast mapping with the same MESMERISED sequence and the same readout train. MESMERISED extends possibilities to efficiently probe T1, T2 and diffusion contrast for multi-component modeling of tissue microstructure.

neuroscience↗