bioRxiv Science⌕ Search

Biology subjects

Plubell, D. L.

Publications and source records attributed to Plubell, D. L..

8 recordsLinked to original sources

Revisiting resonance-excitation collision-induced dissociation for data-independent acquisition

Data-independent acquisition (DIA) proteomics relies almost exclusively on beam-type collision-induced dissociation (HCD) because its short activation time supports fast acquisition rates required for DIA. However, HCD requires charge state calibration and is therefore imperfect for mixed-charge DIA isolation windows. Resonance-excitation collision-induced dissociation (reCID) offers a promising alternative to HCD for DIA because the ion activation is effectively independent of charge state. Historically, reCIDs longer activation time has been considered too slow for DIA. Here, we revisit reCID for DIA proteomics using a modified Orbitrap Tribrid Apex MultiOmics mass spectrometer (Apex) that recovers acquisition-matrix overhead as additional ion injection time, enabling reCID acquisition rates comparable to HCD. Using matched acquisition rate settings of tryptic HeLa digests, reCID achieved precursor and protein detections similar to HCD when used with Carafe fine-tuned, fragmentation-matched spectral libraries. Library fine-tuning improved reCID precursor detections more than HCD detections, 24% versus 5%, indicating that HCD-trained prediction models are suboptimal for reCID spectra. ReCID also maintained peptide-level quantitative performance, including ions measured per peptide, precision, and accuracy. Across seven NCI cancer cell lines and pooled mixtures, protein abundance rankings were highly conserved between the Apex reCID and HCD methods, and also across Orbitrap Astral Zoom platforms. These results support reCID as a practical fragmentation mode for DIA proteomics.

biochemistry↗

Development of highly multiplex targeted proteomics assays in biofluids using the Stellar mass spectrometer

The development of targeted assays that monitor biomedically relevant proteins is an important step in bridging discovery experiments to large scale clinical studies. Targeted assays are currently unable to scale to hundreds or thousands of targets. We demonstrate the generation of large-scale assays using a novel hybrid nominal mass instrument. The scale of these assays is achievable with the StellarTM mass spectrometer through the accommodation of shifting retention times by real-time alignment, while being sensitive and fast enough to handle many concurrent targets. Assays were constructed using precursor information from gas-phase fractionated (GPF) data-independent acquisition (DIA). We demonstrate the ability to schedule methods from an orbitrap and linear ion trap acquired GPF DIA library and compare the quantification of a matrix-matched calibration curve from orbitrap DIA and linear ion trap parallel reaction monitoring (PRM). Two applications of these proposed workflows are shown with a cerebrospinal fluid (CSF) neurodegenerative disease protein PRM assay and with a Mag-Net enriched plasma extracellular vesicle (EV) protein survey PRM assay.

biochemistry↗

Data Independent Acquisition to Inform the Development of Targeted Proteomics Assays Using a Triple Quadrupole Mass Spectrometer

Mass spectrometry based targeted proteomics methods provide sensitive and high-throughput analysis of selected proteins. To develop a targeted bottom-up proteomics assay, peptides must be evaluated as proxies for the measurement of a protein or proteoform in a biological matrix. Candidate peptide selection typically relies on predetermined biochemical properties, data from semi-stochastic sampling, or by empirical measurements. These strategies require extensive testing and method refinement due to the difficulties associated with prediction of peptide response in the biological matrix of interest. Gas-phase fractionated (GPF) narrow window data-independent acquisition (DIA) aids in the development of reproducible selected reaction monitoring (SRM) assays by providing matrix-specific information on peptide detectability and quantification by mass spectrometry. To demonstrate the suitability of DIA data for selecting peptide targets, we reimplement a portion of an existing assay to measure 98 Alzheimers disease proteins in cerebrospinal fluid (CSF). Peptides were selected from GPF-DIA based on signal intensity and reproducibility. The resulting SRM assay exhibits similar quantitative precision to published data, despite the inclusion of different peptides between the assays. This workflow enables development of new assays without additional up-front data acquisition, demonstrated here through generation of a separate assay for an unrelated set of proteins in CSF from the same dataset.

biochemistry↗

A framework for quality control in quantitative proteomics

A thorough evaluation of the quality, reproducibility, and variability of bottom-up proteomics data is necessary at every stage of a workflow from planning to analysis. We share vignettes applying adaptable quality control (QC) measures to assess sample preparation, system function, and quantitative analysis. System suitability samples are repeatedly measured longitudinally with targeted methods, and we share examples where they are used on three instrument platforms to identify severe system failures and track function over months to years. Internal QCs incorporated at protein and peptide-level allow our team to assess sample preparation issues and to differentiate system failures from sample-specific issues. External QC samples prepared alongside our experimental samples are used to verify the consistency and quantitative potential of our results during batch correction and normalization before assessing biological phenotypes. We combine these controls with rapid analysis (Skyline), longitudinal QC metrics (AutoQC), and server-based data deposition (PanoramaWeb). We propose that this integrated approach to QC is a useful starting point for groups to facilitate rapid quality control assessment to ensure that valuable instrument time is used to collect the best quality data possible. Data are available on Panorama Public and on ProteomeXchange under the identifier PXD051318.

biochemistry↗

Mag-Net: Rapid enrichment of membrane-bound particles enables high coverage quantitative analysis of the plasma proteome

Membrane-bound particles in plasma are composed of exosomes, microvesicles, and apoptotic bodies and represent [~]1-2% of the total protein composition. Proteomic interrogation of this subset of plasma proteins augments the representation of tissue-specific proteins, representing a "liquid biopsy," while enabling the detection of proteins that would otherwise be beyond the dynamic range of liquid chromatography-tandem mass spectrometry of unfractionated plasma. We have developed an enrichment strategy (Mag-Net) using hyper-porous strong-anion exchange magnetic microparticles to sieve membrane-bound particles from plasma. The Mag-Net method is robust, reproducible, inexpensive, and requires <100 L plasma input. Coupled to a quantitative data-independent mass spectrometry analytical strategy, we demonstrate that we can collect results for >37,000 peptides from >4,000 plasma proteins with high precision. Using this analytical pipeline on a small cohort of patients with neurodegenerative disease and healthy age-matched controls, we discovered 204 proteins that differentiate (q-value < 0.05) patients with Alzheimers disease dementia (ADD) from those without ADD. Our method also discovered 310 proteins that were different between Parkinsons disease and those with either ADD or healthy cognitively normal individuals. Using machine learning we were able to distinguish between ADD and not ADD with a mean ROC AUC = 0.98 {+/-} 0.06.

biochemistry↗

Can we put Humpty Dumpty back together again? What does protein quantification mean in bottom-up proteomics?

Bottom-up proteomics provides peptide measurements and has been invaluable for moving proteomics into large-scale analyses. In bottom-up proteomics, protein parsimony and protein inference derived from these measured peptides are important for determining which protein coding genes are present. However, given the complexity of RNA splicing processes, and how proteins can be modified post-translationally, it is overly simplistic to assume that all peptides that map to a singular protein coding gene will demonstrate the same quantitative response. Accordingly, by assuming all peptides from a protein coding sequence are representative of the same protein we may be missing out on detecting important biological differences. To better account for the complexity of the proteome we need to think of new or better ways of handling peptide data.

biochemistry↗

Improving power while controlling the false discovery rate when only a subset of peptides are relevant

The standard proteomics database search strategy involves searching spectra against a peptide database and estimating the false discovery rate (FDR) of the resulting set of peptide-spectrum matches. One assumption of this protocol is that all the peptides in the database are relevant to the hypothesis being investigated. However, in settings where researchers are interested in a subset of peptides, alternative search and FDR control strategies are needed. Recently, two methods were proposed to address this problem: subset-search and all-sub. We show that both methods fail to control the FDR. For subset-search, this failure is due to the presence of "neighbor" peptides, which are defined as irrelevant peptides with a similar precursor mass and fragmentation spectrum as a relevant peptide. Not considering neighbors compromises the FDR estimate because a spectrum generated by an irrelevant peptide can incorrectly match well to a relevant peptide. Therefore, we have developed a new method, "filter then subsetneighbor search" (FSNS), that accounts for neighbor peptides. We show evidence that FSNS properly controls the FDR when neighbors are present and that FSNS outperforms group-FDR, the only other method able to control the FDR relative to a subset of relevant peptides.

bioinformatics↗

Genetic control of the HDL proteome

High-density lipoproteins (HDL) are nanoparticles with >80 associated proteins, phospholipids, cholesterol and cholesteryl esters. A comprehensive genetic analysis of the regulation of proteome of HDL isolated from a panel of 100 diverse inbred strains of mice, Hybrid Mouse Diversity Panel (HMDP), revealed widely varied HDL protein levels across the strains. Some of this variation was explained by local, cis-acting regulation, termed cis-protein quantitative trait loci. Variations in apolipoprotein A-II and apolipoprotein C-3 affected the abundance of multiple HDL proteins indicating a coordinated regulation. We identified modules of co-varying proteins and define a protein-protein interaction network describing the protein composition of the naturally occurring subspecies of HDL in mice. Sterol efflux capacity varied up to 3-fold across the strains and HDL proteins displayed distinct correlation patterns with macrophage and ABCA1 specific cholesterol efflux capacity and cholesterol exchange, suggesting that subspecies of HDL participate in discrete functions. The baseline and stimulated sterol efflux capacity phenotypes associated with distinct QTLs with smaller effect size suggesting a multi genetic regulation. Our results highlight the complexity of HDL particles by revealing high degree of heterogeneity and intercorrelation, some of which is associated with functional variation, supporting the concept that HDL-cholesterol alone is not an accurate measure of HDLs properties such as protection against CAD.

systems biology↗