bioRxiv Science⌕ Search

Biology subjects

Pitteri, S. J.

Publications and source records attributed to Pitteri, S. J..

2 recordsLinked to original sources

A Microneedle Device for Rapid Dermal Interstitial Fluid Sampling

Dermal interstitial fluid (ISF) offers a promising alternative to invasive blood tests and opportunities for novel skin diagnostics. Progress in both the understanding and adoption of ISF tests is hindered by sampling challenges, including lengthy collection times, non-negligible failure rates, variable collection volumes, and inconsistent bioanalyte levels. The causes of many of these issues are not well understood. We demonstrate a microneedle device that is several times faster than state-of-the-art, collecting an average of 15.5 mg of ISF in 5 minutes in humans with near-zero failure rate. This improvement was achieved by designing the spatial pressure gradient driving ISF flow. The influence of penetration depth, collection time, pressure, and age on ISF collection was elucidated, with Darcys law explaining multiple observations. A data-driven acceptance criterion of <1% blood contamination for ISF is proposed. The device and findings presented will empower researchers to better conduct robust studies in the development of ISF diagnostics.

bioengineering↗

Lineage plasticity in SCLC generates non-neuroendocrine cells primed for vasculogenic mimicry

IntroductionVasculogenic mimicry (VM), the process of tumor cell trans-differentiation to endow endothelial-like characteristics supporting de novo vessel formation, is associated with poor prognosis in several tumor types, including small cell lung cancer (SCLC). In genetically engineered mouse models (GEMMs) of SCLC, NOTCH and MYC co-operate to drive a neuroendocrine (NE) to non-NE phenotypic switch and co-operation between NE and non-NE cells is required for metastasis. Here, we define the phenotype of VM-competent cells and molecular mechanisms underpinning SCLC VM using circulating tumor cell-derived explant (CDX) models and GEMMs. MethodsWe analysed perfusion within VM vessels and their association with NE and non-NE phenotypes using multiplex immunohistochemistry in CDX and GEMMs. VM-proficient cell subpopulations in ex vivo cultures were molecularly profiled by RNA sequencing and mass spectrometry. We evaluated their 3D structure and defined collagen-integrin interactions. ResultsWe show that VM vessels are present in 23/25 CDX models and in 2 GEMMs. Perfused VM vessels support tumor growth and only Notch-active non-NE cells are VM-competent in vivo and ex vivo, expressing pseudohypoxia, blood vessel development and extracellular matrix (ECM) organization signatures. On Matrigel, VM-primed non-NE cells re-model ECM into hollow tubules in an integrin {beta}1-dependent process. ConclusionsWe identify VM as an exemplar of functional heterogeneity and plasticity in SCLC and these findings take significant steps towards understanding the molecular events that enable VM. These results support therapeutic co-targeting of both NE and non-NE cells to curtail SCLC progression and to improve SCLC patient outcomes in future.

cancer biology↗