bioRxiv ScienceSearch

Biology subjects

Peyton, S.

Publications and source records attributed to Peyton, S..

8 recordsLinked to original sources

Applicability of Drug Response Metrics for Cancer Studies using Biomaterials

Bioengineers have built increasingly sophisticated models of the tumor microenvironment in which to study cell-cell interactions, mechanisms of cancer growth and metastasis, and to test new potential therapies. These models allow researchers to culture cells in conditions that include features of the in vivo tumor microenvironment (TME) implicated in regulating cancer progression, such as ECM stiffness, integrin binding to the ECM, immune and stromal cells, growth factor and cytokine depots, and a 3D geometry more representative of the TME than tissue culture polystyrene (TCPS). These biomaterials could be particularly useful for drug screening applications to make better predictions of efficacy, offering better translation to preclinical in vivo models and clinical trials. However, it can be challenging to compare drug response reports across different platforms and conditions in the current literature. This is, in part, as a result of inconsistent reporting and use of drug response metrics, and vast differences in cell growth rates across a large variety of biomaterial design. This perspective paper attempts to clarify the definitions of drug response measurements used in the field, and presents examples in which these measurements can and cannot be applied. We suggest as best practice to include appropriate controls, always measure the growth rate of cells in the absence of drug, and follow our provided \"decision tree\" matrix when reporting drug response metrics.

bioengineering

A synthetic, three-dimensional bone marrow hydrogel

Three-dimensional (3D) synthetic hydrogels have recently emerged as desirable in vitro cell culture platforms capable of representing the extracellular geometry, elasticity, and water content of tissue in a tunable fashion. However, they are critically limited in their biological functionality. Hydrogels are typically decorated with a scant 1-3 peptide moieties to direct cell behavior, which vastly underrepresents the proteins found in the extracellular matrix (ECM) of real tissues. Further, peptides chosen are ubiquitous in ECM, and are not derived from specific proteins. We developed an approach to incorporate the protein complexity of specific tissues into the design of biomaterials, and created a hydrogel with the elasticity of marrow, and 20 marrow-specific cell-instructive peptides. Compared to generic PEG hydrogels, our marrow-inspired hydrogel improves stem cell differentiation and proliferation. We propose this tissue-centric approach as the next generation of 3D hydrogel design for applications in tissue engineering.

bioengineering

Cross-Platform Mechanical Characterization of Lung Tissue

Published data on the mechanical strength and elasticity of lung tissue is widely variable, primarily due to differences in how testing was conducted across individual studies. This makes it extremely difficult to find a benchmark modulus of lung tissue when designing synthetic extracellular matrices (ECMs). To address this issue, we tested tissues from various areas of the lung using multiple characterization techniques, including micro-indentation, small amplitude oscillatory shear (SAOS), uniaxial tension, and cavitation rheology. We report the sample preparation required and data obtainable across these unique but complimentary methods to quantify the modulus of lung tissue. We highlight cavitation rheology as a new method, which can measure the modulus of intact tissue with precise spatial control, and reports a modulus on the length scale of typical tissue heterogeneities. Shear rheology, uniaxial, and indentation testing require heavy sample manipulation and destruction; however, cavitation rheology can be performed in situ across nearly all areas of the lung with minimal preparation. The Youngs modulus of bulk lung tissue using microindentation (1.9{+/-}0.5 kPa), SAOS (3.2{+/-}0.6 kPa), uniaxial testing (3.4{+/-}0.4 kPa), and cavitation rheology (6.1{+/-}1.6 kPa) were within the same order of magnitude, with higher values consistently reported from cavitation, likely due to our ability to keep the tissue intact. Although cavitation rheology does not capture the non-linear strains revealed by uniaxial testing and SAOS, it provides an opportunity to measure mechanical characteristics of lung tissue on a microscale level on intact tissues. Overall, our study demonstrates that each technique has independent benefits, and each technique revealed unique mechanical features of lung tissue that can contribute to a deeper understanding of lung tissue mechanics.

bioengineering

Anomalous Diffusion as a Descriptive Model of Cell Migration

Appropriately chosen descriptive models of cell migration in biomaterials will allow researchers to characterize and ultimately predict the movement of cells in engineered systems for a variety of applications in tissue engineering. The persistent random walk (PRW) model accurately describes cell migration on two-dimensional (2D) substrates. However, this model inherently cannot describe subdiffusive cell movement, i.e. migration paths in which the root mean square displacement increases more slowly than the square root of the time interval. Subdiffusivity is a common characteristic of cells moving in confined environments, such as three-dimensional (3D) porous scaffolds, hydrogel networks, and in vivo tissues. We demonstrate that a generalized anomalous diffusion (AD) model, which uses a simple power law to relate the mean square displacement (MSD) to time, more accurately captures individual cell migration paths across a range of engineered 2D and 3D environments than does the more commonly used PRW model. We used the AD model parameters to distinguish cell movement profiles on substrates with different chemokinetic factors, geometries (2D vs 3D), substrate adhesivities, and compliances. Although the two models performed with equal precision for superdiffusive cells, we suggest a simple AD model, in lieu of PRW, to describe cell trajectories in populations with a significant subdiffusive fraction, such as cells in confined, 3D environments.

bioengineering

Complementary, High-throughput Methods for Creating Multi-dimensional, PEG-based Biomaterials

Tunable biomaterials that mimic selected features of the extracellular matrix (ECM), such as its stiffness, protein composition, and dimensionality, are increasingly popular for studying how cells sense and respond to ECM cues. In the field, there exists a significant trade-off for how complex and how well these biomaterials represent the in vivo microenvironment, versus how easy they are to make and how adaptable they are to automated fabrication techniques. To address this need to integrate more complex biomaterials design with high-throughput screening approaches, we present several methods to fabricate synthetic biomaterials in 96-well plates and demonstrate that they can be adapted to semi-automated liquid handling robotics. These platforms include 1) glass bottom plates with covalently attached ECM proteins, and 2) hydrogels with tunable stiffness and protein composition with either cells seeded on the surface, or 3) laden within the three-dimensional hydrogel matrix. This study includes proof-of-concept results demonstrating control over breast cancer cell line phenotypes via these ECM cues in a semi-automated fashion. We foresee the use of these methods as a mechanism to bridge the gap between high-throughput cell-matrix screening and engineered ECM-mimicking biomaterials.

bioengineering

Control of Thiol-Maleimide Reaction Kinetics in PEG Hydrogel Networks

Michael-type addition reactions are widely used to polymerize biocompatible hydrogels. The thiol-maleimide modality achieves the highest macromer coupling efficiency of the reported Michael-type pairs, but the resulting hydrogel networks are heterogeneous, because polymerization is faster than the individual components can be manually mixed. The reactivity of the thiol dictates the overall reaction speed, which can be slowed in organic solvents and acidic buffers. Since these modifications also reduce the biocompatibility of resulting hydrogels, we investigated a series of biocompatible buffers and crosslinkers to decelerate gelation while maintaining high cell viability. We found that lowering the polymer weight percentage (wt%), buffer concentration, and pH slowed gelation kinetics, but crosslinking with an electronegative peptide was optimal for both kinetics and cell viability. Slowing the speed of polymerization resulted in more uniform hydrogels, both in terms of visual inspection and the diffusion of small molecules through the network. However, reactions that were too slow resulted in non-uniform particle dispersion due to settling, thus there is a trade-off in hydrogel network uniformity versus cell distribution in the hydrogels when using these networks in cell applications.

bioengineering

Zwitterionic hydrogels modulate the foreign body response in a modulus-dependent manner

Reducing the foreign body response (FBR) to implanted biomaterials will enhance their in vivo performance in tissue engineering. Poly(ethylene glycol) (PEG) hydrogels are increasingly popular for this application due to their low cost and ease of use. PEG hydrogels can elicit chronic inflammation upon implantation, but recent evidence has suggested that extremely hydrophilic, zwitterionic hydrogels can reduce the FBR to particles and gels. To expand on this approach, we synthesized hydrogels of co-monomers PEG and the zwitterion phosphorylcholine (PC) to quantify the combinatorial effects of modulus and hydrophilicity on the FBR. Surprisingly, hydrogels with the highest amount of zwitterionic co-monomer elicited the highest FBR we observed. Lowering the hydrogel modulus (165 kPa to 3 kPa), or PC content (20 wt% to 0 wt%), mitigated this effect. A high density of macrophages was found at the surface of implants associated with a high FBR, and mass spectrometry analysis of the proteins adsorbed to these gels implicated extracellular matrix, immune response, and cell adhesion protein categories as drivers of macrophage recruitment to these hydrogels. Overall, we show that modulus regulates macrophage adhesion to zwitterionic-PEG hydrogels, and demonstrate that chemical modifications to hydrogels should be studied in parallel with their physical properties to optimize implant design.\n\nHighlightsO_LIModulus and zwitterion content independently modulate the foreign body response to soft hydrogels\nC_LIO_LISoft PEG hydrogels synthesized with the zwitterionic PC co-monomer are pro-inflammatory as modulus is increased\nC_LIO_LIThe chemical and physical properties of hydrogels influence the foreign body response via macrophage recruitment and protein adsorption\nC_LI

bioengineering

A Biomaterial Screening Approach to Reveal Microenvironmental Mechanisms of Drug Resistance

TOC FigureDrug response screening, gene expression, and kinome signaling were combined across biomaterial platforms to combat adaptive resistance to sorafenib.\n\n\n\nO_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=158 SRC=\"FIGDIR/small/168039_ufig1.gif\" ALT=\"Figure 1\">\nView larger version (60K):\norg.highwire.dtl.DTLVardef@a7af0eorg.highwire.dtl.DTLVardef@d5f2bborg.highwire.dtl.DTLVardef@330bd6org.highwire.dtl.DTLVardef@14e1f1d_HPS_FORMAT_FIGEXP M_FIG C_FIG Insight BoxWe combined biomaterial platforms, drug screening, and systems biology to identify mechanisms of extracellular matrix-mediated adaptive resistance to RTK-targeted cancer therapies. Drug response was significantly varied across biomaterials with altered stiffness, dimensionality, and cell-cell contacts, and kinome reprogramming was responsible for these differences in drug sensitivity. Screening across many platforms and applying a systems biology analysis were necessary to identify MEK phosphorylation as the key factor associated with variation in drug response. This method uncovered the combination therapy of sorafenib with a MEK inhibitor, which decreased viability on and within biomaterials in vitro, but was not captured by screening on tissue culture plastic alone. This combination therapy also reduced tumor burden in vivo, and revealed a promising approach for combating adaptive drug resistance.\n\nAbstractTraditional drug screening methods lack features of the tumor microenvironment that contribute to resistance. Most studies examine cell response in a single biomaterial platform in depth, leaving a gap in understanding how extracellular signals such as stiffness, dimensionality, and cell-cell contacts act independently or are integrated within a cell to affect either drug sensitivity or resistance. This is critically important, as adaptive resistance is mediated, at least in part, by the extracellular matrix (ECM) of the tumor microenvironment. We developed an approach to screen drug responses in cells cultured on 2D and in 3D biomaterial environments to explore how key features of ECM mediate drug response. This approach uncovered that cells on 2D hydrogels and spheroids encapsulated in 3D hydrogels were less responsive to receptor tyrosine kinase (RTK)-targeting drugs sorafenib and lapatinib, but not cytotoxic drugs, compared to single cells in hydrogels and cells on plastic. We found that transcriptomic differences between these in vitro models and tumor xenografts did not reveal mechanisms of ECM-mediated resistance to sorafenib. However, a systems biology analysis of phospho-kinome data uncovered that variation in MEK phosphorylation was associated with RTK-targeted drug resistance. Using sorafenib as a model drug, we found that co-administration with a MEK inhibitor decreased ECM-mediated resistance in vitro and reduced in vivo tumor burden compared to sorafenib alone. In sum, we provide a novel strategy for identifying and overcoming ECM-mediated resistance mechanisms by performing drug screening, phospho-kinome analysis, and systems biology across multiple biomaterial environments.

bioengineering