bioRxiv ScienceSearch

Biology subjects

Peterchev, A. V.

Publications and source records attributed to Peterchev, A. V..

4 recordsLinked to original sources

Statistical Model of Motor Evoked Potentials for Simulation of Transcranial Magnetic and Electric Stimulation

Motor evoked potentials (MEPs) are widely used for biomarkers and dose individualization in transcranial stimulation. The large variability of MEPs requires sophisticated methods of analysis to extract information fast and correctly. However, models of MEPs that represent their characteristic features are lacking. This work presents a statistical model that can simulate long sequences of individualized MEP amplitude data with properties matching experimental observations. The MEP model includes three sources of trial-to-trial variability to mimic excitability fluctuations, variability in the neural and muscular pathways, and physiological and measurement noise. It also generates virtual human subject data from statistics of population variability. All parameters are extracted as statistical distributions from experimental data from the literature. The model exhibits previously described features, such as stimulusintensity-dependent MEP amplitude distributions, including bimodal ones. The model can generate long sequences of test data for individual subjects with specified parameters or for subjects from a virtual population. The presented MEP model is the most detailed to date and can be used for the development and implementation of dosing and biomarker estimation algorithms for transcranial stimulation.

physiology

Biophysically Realistic Neuron Models for Simulation of Cortical Stimulation

1.ObjectiveWe implemented computational models of human and rat cortical neurons for simulating the neural response to cortical stimulation with electromagnetic fields.\n\nApproachWe adapted model neurons from the library of Blue Brain models to reflect biophysical and geometric properties of both adult rat and human cortical neurons and coupled the model neurons to exogenous electric fields (E-fields). The models included 3D reconstructed axonal and dendritic arbors, experimentally-validated electrophysiological behaviors, and multiple, morphological variants within cell types. Using these models, we characterized the single-cell responses to intracortical microstimulation (ICMS) and uniform E-field with dc as well as pulsed currents.\n\nMain resultsThe strength-duration and current-distance characteristics of the model neurons to ICMS agreed with published experimental results, as did the subthreshold polarization of cell bodies and axon terminals by uniform dc E-fields. For all forms of stimulation, the lowest threshold elements were terminals of the axon collaterals, and the dependence of threshold and polarization on spatial and temporal stimulation parameters was strongly affected by morphological features of the axonal arbor, including myelination, diameter, and branching.\n\nSignificanceThese results provide key insights into the mechanisms of cortical stimulation. The presented models can be used to study various cortical stimulation modalities while incorporating detailed spatial and temporal features of the applied E-field.

bioengineering

Design of Transcranial Magnetic Stimulation Coils with Optimal Trade-off between Depth, Focality, and Energy

BackgroundTranscranial magnetic stimulation (TMS) is a noninvasive brain stimulation technique used for research and clinical applications. Existent TMS coils are limited in their precision of spatial targeting (focality), especially for deeper targets.\n\nObjectiveThis paper presents a methodology for designing TMS coils to achieve optimal trade-off between the depth and focality of the induced electric field (E-field), as well as the energy required by the coil.\n\nMethodsA multi-objective optimization technique is used for computationally designing TMS coils that achieve optimal trade-offs between stimulation focality, depth, and energy (fdTMS coils). The fdTMS coil winding(s) maximize focality (minimize stimulated volume) while reaching a target at a specified depth and not exceeding predefined peak E-field strength and required coil energy. Spherical and MRI-derived head models are used to compute the fundamental depth-focality trade-off as well as focality-energy trade-offs for specific target depths.\n\nResultsAcross stimulation target depths of 1.0-3.4 cm from the brain surface, the stimulated volume can be theoretically decreased by 42%-55% compared to existing TMS coil designs. The stimulated volume of a figure-8 coil can be decreased by 36%, 44%, or 46%, for matched, doubled, or quadrupled energy. For matched focality and energy, the depth of a figure-8 coil can be increased by 22%.\n\nO_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=153 SRC=\"FIGDIR/small/300616_fig8.gif\" ALT=\"Figure 8\">\nView larger version (14K):\norg.highwire.dtl.DTLVardef@af0b5org.highwire.dtl.DTLVardef@4118d8org.highwire.dtl.DTLVardef@1c61f80org.highwire.dtl.DTLVardef@3e23fa_HPS_FORMAT_FIGEXP M_FIG O_FLOATNOFigure 8.C_FLOATNO Energy, W, vs. spread, S1/2, curves for hand knob stimulation for a conventional figure-8 coil and optimized fdTMS coil on a 32 x 32 cm square plane.\n\nC_FIG ConclusionComputational design of TMS coils could enable more selective targeting of the induced E-field. The presented results appear to be the first significant advancement in the depth-focality trade-off of TMS coils since the introduction of the figure-8 coil three decades ago, and likely represent the fundamental physical limit.\n\nDECLARATION OF INTERESTThe fdTMS technology described in this paper is subject to a provisional patent application by Duke University with the authors as inventors. Additionally: L.J.G. is inventor on a patent pertaining to the design of focal multicoil TMS systems. S.M.G. is inventor on patents and patent applications; he has received royalties from Rogue Research, TU Muenchen, and Porsche; furthermore, he has been provided with research support and patent fee reimbursement from Magstim Co. A.V.P. is inventor on patents and patent applications, and has received research and travel support as well as patent royalties from Rogue Research; research and travel support, consulting fees, as well as equipment loan from Tal Medical / Neurex; patent application and research support from Magstim; and equipment loans from MagVenture, all related to technology for transcranial magnetic stimulation.

bioengineering

Coupling magnetically induced electric fields to neurons: longitudinal and transverse activation

We present a theory and computational models to couple the electric field induced by magnetic stimulation to neuronal membranes. The response of neuronal membranes to induced electric fields is examined under different time scales, and the characteristics of the primary and secondary electric fields from electromagnetic induction and charge accumulation on conductivity boundaries, respectively, are analyzed. Based on the field characteristics and decoupling of the longitudinal and transverse field components along the neural cable, quasi-potentials are a simple and accurate approximation for coupling of magnetically induced electric fields to neurons and a modified cable equation provides theoretical consistency for magnetic stimulation. The conventional and modified cable equations are used to simulate magnetic stimulation of long peripheral nerves by circular and figure-8 coils. Activation thresholds are obtained over a range of lateral and vertical coil positions for two nonlinear membrane models representing unmyelinated and myelinated axons and also for undulating myelinated axons. For unmyelinated straight axons, the thresholds obtained with the modified cable equation are significantly lower due to transverse polarization, and the spatial distributions of thresholds as a function of coil position differ significantly from predictions by the activating function. For myelinated axons, the transverse field contributes negligibly to activation thresholds, whereas axonal undulation can increase or decrease thresholds depending on coil position. The analysis provides a rigorous theoretical foundation and implementation methods for the use of the cable equation to model neuronal response to magnetically induced electric fields. Experimentally observed stimulation with the electric fields perpendicular to the nerve trunk cannot be explained by transverse polarization alone and is likely due to nerve fiber undulation and other geometrical inhomogeneities.

bioengineering