bioRxiv Science⌕ Search

Biology subjects

Pengo, T.

Publications and source records attributed to Pengo, T..

8 recordsLinked to original sources

Scaling up polarization-sensitive optical coherence tomography to image the whole macaque brain

Polarization-sensitive optical coherence tomography (PS-OCT) is a label-free imaging technique that exploits birefringence to visualize myelinated axons at micrometer resolution. However, serial PS-OCT imaging has been limited to small volumes, including tissue blocks from larger species, owing to constraints in acquisition speed, system stability, and data processing. These limitations have prevented its application to whole-brain mapping in large mammals. Here we present a scalable PS-OCT acquisition system and computational pipeline for whole-brain imaging in the rhesus macaque. The framework integrates high-throughput serial imaging with automated reconstruction and processing, enabling volumetric imaging at micrometer-scale resolution across decimeter-scale brain volumes. Using this approach, we acquired two complete macaque brains at a voxel size of 5.5 x 5.5 x 3.4 m and an effective resolution of approximately 10 x 10 x 5.5 m, generating multi-terabyte datasets consisting of multiple contrasts including fiber orientation information. The datasets and associated processing tools are made publicly available. This platform establishes a method for large-scale, high-resolution mapping of white matter architecture in primate brains. The resulting datasets provide a reference for validating MRI models and support the development of neurotechnological applications, including deep brain stimulation, where accurate characterization of axonal organization is required.

neuroscience↗

Motion Impact Score for Detecting Spurious Brain-Behavior Associations

Between-participant differences in head motion introduce systematic bias to resting state fMRI brain-wide association studies (BWAS) that is not completely removed by denoising algorithms. Researchers who study traits, or phenotypes associated with in-scanner head motion (e.g. psychiatric disorders) need to know if trait-functional connectivity (FC) effects are biased by residual motion artifact in order to avoid reporting false positive results. We devised an adaptable method, Split Half Analysis of Motion Associated Networks (SHAMAN), to assign a motion impact score to specific trait-FC effects. The SHAMAN approach distinguishes between motion artifact causing overestimation or underestimation of trait-FC effects. SHAMAN was > 95% specific at sample sizes of n = 100 and above. SHAMAN was powered to detect motion overestimation scores 80% of the time at sample sizes of n = 5,000 but could detect motion underestimation scores only 50% of the time at n = 5000, making it most useful for researchers seeking to avoid overestimating trait-FC effects in large BWAS. We computed motion impact scores for trait-FC effect with 45 demographic, biophysical, cognitive, and personality traits from n = 7,270 participants in the Adolescent Brain Cognitive Development (ABCD) Study. After standard denoising with ABCD-BIDS and without motion censoring, 42% (19/45) of traits had significant (p < 0.05) motion overestimation scores and 38% (17/45) of traits had significant motion underestimation scores. Censoring at framewise displacement (FD) < 0.2 mm reduced the proportion of traits with significant motion overestimation scores from 42% to 2% (1/45) but did not decrease the number of traits with significant motion underestimation scores.

neuroscience↗

Tissue-Like 3D Standard and Protocols for Microscope Quality Management

This article outlines a global study conducted by the Association of Biomedical Resource Facilities (ABRF) Light Microscopy Research Group (LMRG). The results present a novel 3D tissue-like biologically relevant standard sample that is affordable and straightforward to prepare. Detailed sample preparation and instrument specific image acquisition protocols and image analysis methods are presented and made available to the community. The standard consists of sub-resolution and large well characterized relative intensity fluorescence microspheres embedded in a 120 {micro}m thick 3D gel with a refractive index of 1.365. The standard allows the evaluation of several properties as a function of depth. These include: 1) microscope resolution with automated analysis of the point spread function (PSF), 2) automated signal-to-noise- ratio analysis, 3) calibration and correction of fluorescence intensity loss, and 4) quantitative relative intensity. Results demonstrate expected refractive index mismatch dependent losses in intensity and resolution with depth but the relative intensities of different objects at similar depths were maintained. This is a robust standard showing reproducible results across laboratories, microscope manufacturers and objective lens types (e.g. magnification, immersion medium). Thus, these tools will be valuable for the global community to benchmark fluorescence microscopes and will contribute to improved rigor and reproducibility.

cell biology↗

Dynein acts to cluster glutamate receptors and traffic the PIP5 kinase, Skittles, to regulate postsynaptic membrane organization at the neuromuscular junction

Cytoplasmic dynein is essential in motoneurons for retrograde cargo transport that sustains neuronal connectivity. Little, however, is known about dyneins function on the postsynaptic side of the circuit. Here we report distinct postsynaptic roles for dynein at neuromuscular junctions (NMJs). Intriguingly, we show that dynein punctae accumulate postsynaptically at glutamatergic synaptic terminals. Moreover, Skittles, a phosphatidylinositol 4-phosphate 5-kinase that produces PI(4,5)P2 to organize the spectrin cytoskeleton, also localizes specifically to glutamatergic synaptic terminals. Depletion of postsynaptic dynein disrupts the accumulation of Skittles, PI(4,5)P2 phospholipid, and organization of the spectrin cytoskeleton at the postsynaptic membrane. Coincidental with dynein depletion, we observe an increase in the clusters size of ionotropic glutamate receptor (iGluR), and an increase in the amplitude and frequency of mEJPs. However, PI(4,5)P2 levels do not affect iGluR clustering and dynein does not affect the protein levels of iGluR subunits at the NMJ, suggesting a separate, transport independent function for dynein in iGluR cluster organization. As dynein punctae closely associate with iGluR clusters, we propose that dynein physically tethers iGluR clusters at the postsynaptic membrane to ensure proper synaptic transmission.

cell biology↗

MethodsJ2: A Software Tool to Improve Microscopy Methods Reporting

Proper reporting of metadata is essential to reproduce microscopy experiments, interpret results and share images. Experimental scientists can report details about sample preparation and imaging conditions while imaging scientists have the expertise required to collect and report the image acquisition, hardware and software metadata information. MethodsJ2 is an ImageJ/Fiji based software tool that gathers metadata and automatically generates text for the methods section of publications.

bioinformatics↗

PELP1/SRC-3-dependent regulation of metabolic kinases drives therapy resistant ER+ breast cancer

Recurrence of metastatic breast cancer stemming from acquired endocrine and chemotherapy resistance remains a health burden for women with luminal (ER+) breast cancer. Disseminated ER+ tumor cells can remain viable but quiescent for years to decades. Contributing factors to metastatic spread include the maintenance and expansion of breast cancer stem cells (CSCs). Breast CSCs frequently exist as a minority population in therapy resistant tumors. In this study, we show that cytoplasmic complexes composed of steroid receptor (SR) co-activators, PELP1 and SRC-3, modulate breast CSC expansion through upregulation of the HIF-activated metabolic target genes PFKFB3 and PFKFB4. Seahorse metabolic assays demonstrated that cytoplasmic PELP1 influences cellular metabolism by increasing both glycolysis and mitochondrial respiration. PELP1 interacts with PFKFB3 and PFKFB4 proteins, and inhibition of PFKFB3 and PFKFB4 kinase activity blocks PELP1-induced tumorspheres and protein-protein interactions with SRC-3. PFKFB4 knockdown inhibited in vivo emergence of circulating tumor cell (CTC) populations in mammary intraductal (MIND) models. Application of PFKFB inhibitors in combination with ER targeted therapies blocked tumorsphere formation in multiple models of advanced breast cancer, including tamoxifen (TamR) and paclitaxel (TaxR) resistant models and ER+ patient-derived organoids (PDxO). Together, our data suggest that PELP1, SRC-3, and PFKFBs cooperate to drive ER+ tumor cell populations that include CSCs and CTCs. SignificanceIdentifying non-ER pharmacological targets offers a useful approach to blocking metastatic escape from standard of care ER/estrogen (E2)-targeted strategies to overcome endocrine and chemotherapy resistance.

cancer biology↗

Chrysalis: A new method for high-throughput histo-cytometry analysis of images and movies.

Advances in imaging have led to the development of powerful multispectral, quantitative imaging techniques, like histo-cytometry. The utility of this approach is limited, however, by the need for time consuming manual image analysis. We therefore developed the software Chrysalis and a group of Imaris Xtensions to automate this process. The resulting automation allowed for high-throughput histo-cytometry analysis of 3D confocal microscopy and two-photon time-lapse images of T cell-dendritic cell interactions in the spleen. It was also applied to epi-fluorescence images to quantify T cell localization within splenic tissue by using a signal absorption strategy that avoids computationally intensive distance measurements. In summary, this image processing and analysis software makes histo-cytometry more useful for immunology applications by automating image analysis.

immunology↗

Super-resolution fight club: A broad assessment of 2D & 3D single-molecule localization microscopy software

With the widespread uptake of 2D and 3D single molecule localization microscopy, a large set of different data analysis packages have been developed to generate super-resolution images. To guide researchers on the optimal analytical software for their experiments, we have designed, in a large community effort, a competition to extensively characterise and rank these options. We generated realistic simulated datasets for popular imaging modalities - 2D, astigmatic 3D, biplane 3D, and double helix 3D - and evaluated 36 participant packages against these data. This provides the first broad assessment of 3D single molecule localization microscopy software, provides a holistic view of how the latest 2D and 3D single molecule localization software perform in realistic conditions, and ultimately provides insight into the current limits of the field.

biophysics↗