bioRxiv Science⌕ Search

Biology subjects

Pedersen, A. P.

Publications and source records attributed to Pedersen, A. P..

2 recordsLinked to original sources

Attaching artificial Achilles and tibialis cranialis tendons to bone using suture anchors in a rabbit model: assessment of outcomes

ObjectiveThe purpose of this study was to investigate the factors associated with outcomes of attaching artificial tendons to bone using suture anchors for replacement of biological tendons in rabbits. Study DesignMetal suture anchors with braided composite sutures of varying sizes (USP #1, #2, or #5) were used to secure artificial tendons replacing both the Achilles and tibialis cranialis tendons in 12 New Zealand White rabbits. Artificial tendons were implanted either at the time of (immediate replacement, n=8), or four weeks after (delayed replacement, n=4) resection of the biological tendon. Hindlimb radiographs of the rabbits were obtained immediately after surgery and approximately every other week until the study endpoint (16 weeks post-surgery). ResultsAll suture anchors used for the tibialis cranialis artificial tendons remained secure and did not fail during the study. The suture linkage between the Achilles artificial tendon and anchor failed in 9 of 12 rabbits. In all cases, the mode of failure was suture breakage distant from the knot. Based on radiographic analysis, the mean estimated failure timepoint was 5.3{+/-}2.3 weeks post-surgery, with a range of 2-10 weeks. Analysis of variance (ANOVA) tests revealed no significant effect of tendon implantation timing or suture size on either the timing or frequency of suture anchor failure. ConclusionBased on the mode of failure, suture mechanical properties, and suture anchor design, we suspect that the cause of failure was wear of the suture against the edges of the eyelet in the suture anchor post, which reduced the suture strength below in vivo loads. Suture anchor designs differed for the tibialis cranialis and did not fail during the period of study. Future studies are needed to optimize suture anchor mechanical performance under different loading conditions and suture anchor design features.

bioengineering↗

GAIT BIOMECHANICS OF RABBITS WITH EITHER ACHILLES OR TIBIALIS CRANIALIS ARTIFICIAL TENDONS

Artificial tendons have been developed as a replacement for biological tendons with irreparable pathologies and defects. Previous studies reported the mechanical strength and tissue integration of a polyester suture-based artificial tendon, but not its effect on locomotor function. The objective of this study was to quantify the hindlimb biomechanics during hopping gait of New Zealand White rabbits with surgical replacement of either the Achilles (n=2) or tibialis cranialis (TC, n=2) biological tendons with artificial tendons. Once pre-surgery and for five consecutive weeks post-surgery (starting at about two weeks post-surgery), we measured hindlimb kinematics and ground contact pressures with a video camera and pressure mat, respectively. Promisingly, post-surgical locomotor function was either consistent or improved over time in both tendon replacement groups. However, Achilles rabbits exhibited greater immediate post-surgery functional decline and less post-surgical functional recovery than TC rabbits. Compared to healthy rabbits, at the study endpoint, (1) TC rabbits had a 17.3-degree higher (i.e., more plantarflexed) ankle angle at foot strike; and (2) Achilles rabbits had a 39.2-degree lower (i.e., more dorsiflexed) ankle angle at toe off. These functional deficits suggest that the muscles attached to the artificial tendons had lower force-generating capacity. Future studies of artificial tendons are needed to quantify long-term function, determine the effectiveness of structured rehabilitation exercises, and refine surgical implementation.

bioengineering↗